  1. Replies
    11
    Views
    1,823

    Well, that answers my question. I've got 5...

    Well, that answers my question. I've got 5 machines with lithium chromate and 4 barrels of useless, at least to me, trane lithium molybdenum. Thank you for the help guys. I haven't had to evacuate...
  2. Replies
    11
    Views
    1,823

    Lithium Bromide Dilemma

    To the guys who know absorbers: I have Carriers, as many of you already know. The 16JB series. Several years back, we "loaned" our remaining Carrene 16 to a hospital in dire need. We were sent...
  3. Replies
    23
    Views
    1,482

    I had this happen to me as well on a R-22 dual...

    I had this happen to me as well on a R-22 dual evap cooler. Had been in 10 years when I took it over and had two 1 1/2 ton TXV's in it, when the condensing unit called for two 2 ton TXV's. Until...
  4. Replies
    31
    Views
    5,276

    You're not totally wrong, but I'll add to this...

    You're not totally wrong, but I'll add to this with a little more specificity. A hoshi cuber, when initiated by the bin thermostat will energize the fill valve for a short period, and then the...
  5. Replies
    31
    Views
    5,276

    :ditto:

    :ditto:
  6. Replies
    31
    Views
    5,276

    Sounds like you're on the right track with the...

    Sounds like you're on the right track with the compressor. The hg valve is only energized at startup during initial harvest and during harvest when the fill valve is energized. One other thing you...
  7. Replies
    31
    Views
    5,276

    Do you have cubes on every pass of the...

    Do you have cubes on every pass of the evaporator? You said the evap was clean, so let's assume it is for the time being. If you have cubes on all passes, and your float switch is initiating the...
  8. Replies
    10
    Views
    730

    H-10 Maintenance

    You will have to replace the battery at some point, but they are very reasonable if you just look around. I've replaced mine twice in 12 years and replaced one sensor. Other than the occasional tip...
  9. Replies
    10
    Views
    730

    I got my H-10 PM in 1998. I had to have it...

    I got my H-10 PM in 1998. I had to have it refurbished by the factory once. I got caught on a roof with a bunch of tools in the rain one day. Live and learn. It doesn't like water, however, ever...
  10. Replies
    25
    Views
    2,597

    Thanks for the info...much appreciated!

    Thanks for the info...much appreciated!
  11. Replies
    25
    Views
    2,597

    I have a mixture right now. But to answer your...

    I have a mixture right now. But to answer your question, I have a three cell BAC with belt drives and a single cell BAC with belt drive. Each motor has its own drive. Unfortunately, these were...
  12. Replies
    25
    Views
    2,597

    A question, regarding the VFD's specifically. I...

    A question, regarding the VFD's specifically. I read the manual when they were installed a few years ago on my new towers, and a big warning at the front was do not open the disconnect with the VFD...
  13. Replies
    21
    Views
    2,883

    I know you said the condenser was clean, and...

    I know you said the condenser was clean, and forgive me for beating a dead horse if it's truly dead, but I have quite a few of these units on site, and, as you're probably aware, the condenser is...
  14. Replies
    3
    Views
    1,910

    Cooling Tower Vacuum

    Guys, I'm looking at/pricing a cooling tower vacuum right now. We've never had one. Pros/Cons? Does anyone besides Goodway make one? Would appreciate any info on these. Trying to decide if it's...
  15. Replies
    6
    Views
    605

    Spent a few years on hoshis in the late 90's,...

    Spent a few years on hoshis in the late 90's, just as the 404a machines started to emerge. What you're describing sounds like a board issue, possibly a stuck hot gas valve. If your head pressure is...
  16. Replies
    39
    Views
    3,811

    It's June 28th. What's the verdict? I'm really...

    It's June 28th. What's the verdict? I'm really curious on this one.
  17. Sorry jp. This is what I was trying to say, just...

    Sorry jp. This is what I was trying to say, just did a terrible job of it!!
  18. I'm pretty sure you're correct jp. It's one of...

    I'm pretty sure you're correct jp. It's one of the ways they've increased efficiency ratings...less compressor.
  19. Replies
    39
    Views
    3,811

    Not that we can get any further until actual...

    Not that we can get any further until actual readings are taken on this system, but I still think you've either got something in your orifice, you have plugged distributor tubes or your EEV has...
  20. Replies
    13
    Views
    903

    pdrake has you on the right path, so I don't have...

    pdrake has you on the right path, so I don't have anything more to add except thank you for your service and for what you continue to do. I'm still Air Guard and leave for Afg in October. The Army...
  21. Replies
    4
    Views
    693

    Bob's advice to you is, in my opinion at least,...

    Bob's advice to you is, in my opinion at least, the best you can do in a situation like this. I'm an HVAC foreman at a prison hospital, and believe it or not, even with congress spending like...
  22. Replies
    39
    Views
    6,270

    Love Hoshi's

    I have to agree that Hoshi's are by far the least forgiving on lack of maintenance, and ever since they quit using Fuji gearboxes in their flakers, those haven't been the same. But, I've worked on...
  23. Replies
    5
    Views
    650

    It couldn't hurt anything, but it's really...

    It couldn't hurt anything, but it's really impossible to see for certain on your scale buildup unless you shut it down and dry the evap completely. I've found you can have a light coating on there...
  24. Replies
    5
    Views
    650

    I'm not extremely familiar with Crystal Tips,...

    I'm not extremely familiar with Crystal Tips, mainly Mani's and Hoshi's, but if you're making ice in that section, you've got good heat transfer. You might check the condition of your nickel plating...
  25. Replies
    39
    Views
    3,811

    Got a little ahead of the game there....Sorry.

    Got a little ahead of the game there....Sorry.