Search:

Type: Posts; User: swift one

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: Bryant txv

    by swift one
    Replies
    188
    Views
    13,144

    September 5, 2014 Dear Valued Customer: We...

    September 5, 2014

    Dear Valued Customer:

    We have received the following update from Rheem regarding the industry wide TXV issue:

    “Rheem has identified potential root causes of the field...
  2. Thread: Bryant txv

    by swift one
    Replies
    188
    Views
    13,144

    Ok the Product is called ac re New Standard...

    Ok the Product is called ac re New Standard Supply has been known to carry it.Sounds kinda snake oily to me. But heck guys are buying system flush kits too....:grin2:
  3. Thread: Bryant txv

    by swift one
    Replies
    188
    Views
    13,144

    will have more info tomorrow.

    will have more info tomorrow.
  4. Thread: Bryant txv

    by swift one
    Replies
    188
    Views
    13,144

    :grin2:Found out from supplier that the foreign...

    :grin2:Found out from supplier that the foreign cooper is in fact the tar problem. However nu calgon has a chemical to clean it right:grin2: on up
  5. Thread: Bryant txv

    by swift one
    Replies
    188
    Views
    13,144

    I say the copper.Mainly the manufactor/supplier...

    I say the copper.Mainly the manufactor/supplier to the equipment manufactor....
  6. Replies
    30
    Views
    1,492

    possible mixing air..supply and return in curb...

    possible mixing air..supply and return in curb ???just a quik thought
  7. Replies
    53
    Views
    1,871

    funny funny i lmao (crabby non readin old...

    funny funny i lmao (crabby non readin old decrepiteded grummy dried up fart stained drougers wearing bastid. oman funny as hell.
  8. Thread: Bryant txv

    by swift one
    Replies
    188
    Views
    13,144

    Those are stainless steel valves that danfloss...

    Those are stainless steel valves that danfloss are really proud of (no power element to rust).been using/seeing them in manitowoc ice for several years now, when brazing you ONLY heat the copper...
  9. Replies
    10
    Views
    436

    Gaffers????

    Gaffers????
  10. Replies
    6
    Views
    362

    x2

    x2
  11. I have used a plastic tarp sip screwed it to the...

    I have used a plastic tarp sip screwed it to the wall behind the evap dropped/removed evap pan.Got a rubber made large trash can (55gal) with the detachable wheels/caddy bottom, directed the tarp...
  12. smeq,this one of four 2 barrel systems this one...

    smeq,this one of four 2 barrel systems this one is the most popular of flavors.(coke)the owner has to make a decision for he has bought this store and the large chain co.(previous owner) has let the...
  13. Replies
    12
    Views
    1,147

    Tail meat is very tough,sharp knife and...

    Tail meat is very tough,sharp knife and (BFH):censored: or meat mallet
  14. smeq, thanks for insight Hot gas diaphram was...

    smeq, thanks for insight Hot gas diaphram was bleeding the disk had bubble in it. question have you ever changed foam pack/evap barrel on one of these.the unit next to this one all valves and sensors...
  15. WOW well spoken newold

    WOW well spoken newold
  16. Replies
    7
    Views
    524

    danfoss has a couple up and running in EUROPE...

    danfoss has a couple up and running in EUROPE...
  17. yes both barrel valves are energized and out let...

    yes both barrel valves are energized and out let temp drops. However not dropping enough#2 barrel. I was thinking hot gas bleeding,txv seat worn?? On start up ib valve outlet gets cold /cool and...
  18. cornelius pinnacle fcb where to start, or run away

    have one 2 flavor low on refrigerant.weighed in proper amount 20oz barrel 1 just fine barrel 2 wont freeze. ib will not drop below 49 in or out.this has become a huge challenge to say the least....
  19. Defrost timers are very common on med temp...

    Defrost timers are very common on med temp coolers. Here in the south RH cause heavy frosting of evaps
  20. Replies
    23
    Views
    2,667

    x2

    x2
  21. Quite common here if your talking about a utility...

    Quite common here if your talking about a utility bed on pickup truck. Ford, chevy,dodge etc... fleet sales at any dealer can find/outfit for you.
  22. Replies
    11
    Views
    1,225

    with r12 likely unnecessary,more so with 134a(cap...

    with r12 likely unnecessary,more so with 134a(cap tube replacement)
  23. Replies
    13
    Views
    1,187

    The same problem i had this past summer with 2...

    The same problem i had this past summer with 2 true reach-in freezer (3door and 2door) I replace Defrost timer, only to be called back. Thats when fumbling around in the center electrical panel the...
  24. Replies
    13
    Views
    2,854

    Marvin was a true friend.He forgot more than i'll...

    Marvin was a true friend.He forgot more than i'll ever could hope to know. Brought me up in this trade always asked how my kids were doing. Loved you Marv. R.I.P Thank you.Will
  25. Replies
    35
    Views
    3,055

    This may help/ or thought If this unit has a...

    This may help/ or thought If this unit has a baklite blower terminal block in the blower section. remove/ jump around it. Had same problem years back. With a trane gas pak. If memory serves me...