  1. jax training

    in jacksonville there is the northeast florida builders association apprenticeship program. they hook you up with a company and you have set raises, schooling, ride along experience etc...

    i have...
  2. Replies
    11
    Views
    1,386

    sorry for all the misunderstanding

    i always try to upsize the return in retrofits. often we will encounter a house with one return 10 feet inside the house from a garage air handler. often we will run a second flexline say a 12" to a...
  3. Replies
    11
    Views
    1,386

    terminology...

    I guess i used the wrong terminology. i'm trying to say volume of the round flex duct at .1" for example if i lay out a duct system for a 2.5 ton system at 400 cfm per ton i like to have the total...
  4. Replies
    11
    Views
    1,386

    i would reccomend at least 20% more return cfm...

    i would reccomend at least 20% more return cfm than supply.
  5. u.s.a jacksonville beach, fla.

    u.s.a
    jacksonville beach, fla.
  6. Replies
    15
    Views
    1,271

    ditto. mitsubishi, fujitsu, both are excellent,...

    ditto. mitsubishi, fujitsu, both are excellent, customers love them.
  7. Replies
    21
    Views
    2,010

    very interesting... i was an american standard...

    very interesting... i was an american standard dealer for six years until i was offered the chance to become a trane dealer. the trane name is far and away more recognized. it makes things much...
  8. Replies
    88
    Views
    5,129

    31 in jax beach, fl.

    31 in jax beach, fl.
  9. Thread: new name

    by flyin'gator
    Replies
    44
    Views
    3,076

    looks great

    looks great
  10. Replies
    17
    Views
    1,518

    i would highly reccomend you get a manual j heat...

    i would highly reccomend you get a manual j heat load calculation done on this structure. the energy saving improvements you have listed will have a dramatic effect on the amount of a/c tonnage...
  11. yes.

    yes.
  12. asking 11k and located in jacksonville beach,...

    asking 11k and located in jacksonville beach, fl.33250
  13. Replies
    21
    Views
    2,203

    i agree, carrier and goodman tanks go bad often....

    i agree, carrier and goodman tanks go bad often. unless the unit is 8 yrs or older or has a bad coil, we typically do not condemn the unit. we replace the tank, pull hard vacuum, check for additional...
  14. i'm going to use a covered trailer for the...

    i'm going to use a covered trailer for the largest condensers. the other two vans can handle everything else. when the motor blew in dec. i couldn't sell it without a fresh engine.
  15. pics of boxvan

    pics of boxvan
  16. pics as requested.

    pics as requested.
  17. i will attempt to post pics today.

    i will attempt to post pics today.
  18. Replies
    19
    Views
    3,621

    telling a customer to replace those coils is...

    telling a customer to replace those coils is highly unethical. and people wonder why dateline is always out to get us....
  19. abatement tech. duct cleaning set up for sale

    c17-185gh air sweep compressor with 9hp honda motor less than 52hours used
    h2500c hepa vac w/ 52.06 hours run time on it
    heat seal nozzles,air guns,and agitation whips with flexible rods
    5 foot...
  20. 99' gmc 14' boxvan w/ new motor and tranny

    i bought it as a ryder truck in 2001 w/ 80k miles. now she has 135k. new transmission 12000 miles ago in april of '06. new 5.7 engine installed last week with 12 month unlimited miles warranty....
  21. Replies
    57
    Views
    7,578

    definately sounds like a lazy tech. a leak check,...

    definately sounds like a lazy tech. a leak check, repair, vacuum drawdown, and filter dryer is the only way to prevent yourself from constantly throwing away money to both the ac company and the...
  22. Thread: rotobrush

    by flyin'gator
    Replies
    11
    Views
    5,968

    rotobrush is simply not effective. try the...

    rotobrush is simply not effective. try the abatement 2500 and air sweep compressor- that combination actually works and provides value for your customer.
  23. Replies
    15
    Views
    2,222

    in florida we always try to have at least 30%...

    in florida we always try to have at least 30% more return than supply area in retrofit applications. in new construction the energy code has a stipulation that for pass thru ducts you must have 150%...
  24. Replies
    24
    Views
    3,424

    here in jacksonville beach i pay $20-$24 for...

    here in jacksonville beach i pay $20-$24 for five years experience as a tech/installer and start em at $10 with no experience. after ninety days i pay for their health insurance as well. we are a...
  25. Replies
    2
    Views
    511

    sometimes the branch ducts that are closest need...

    sometimes the branch ducts that are closest need some variable damper scoops to catch a little more airflow. of course, this is assuming that you have a properly sized and sealed duct system.