  1. Replies
    11
    Views
    339

    mismatched coils

    I have a customer who sent me a text tonight - he said that he replaced his three ton condenser with a 4 ton (I assume he still has a 3 ton air handler) - he was told he would have colder air. He...
  2. Replies
    7
    Views
    296

    Ok. Are you saying that the reason some...

    Ok. Are you saying that the reason some compressors have horsepower ratings rather than BTU (tonnage) ratings is because one compressor, say CRN-5 can have different BTU ratings - depending on the...
  3. Replies
    7
    Views
    296

    Horsepower / BTU's

    I don't understand why some compressors are rated in tons/BTU's and others (freezers, coolers, etc) are rated in horsepower.
    Is there a difference in the compressors themselves?
  4. Thread: insulation

    by tonydykes55
    Replies
    2
    Views
    231

    insulation

    I'm relocating some supply ducts - they are between studs - in the wall cavity. Since they will be encased between studs and sheetrock, will they need insulation. The ones I'm replacing did not have...
  5. Replies
    0
    Views
    167

    heil quaker

    Can anyone help me determine the size of this unit.
    I think it's a 2 ton. The house is 1000 sq.ft.
    Heil Quaker condenser model CU325AOD1C.
    Compressor nameplate - model SRC4-0020-??
  6. Thread: pump down

    by tonydykes55
    Replies
    19
    Views
    773

    thanks, this has been very educational.

    thanks, this has been very educational.
  7. Thread: pump down

    by tonydykes55
    Replies
    19
    Views
    773

    I understand. So then, in an typical residential...

    I understand. So then, in an typical residential split system for example, would I be correct in thinking that since the indoor ambient is typically 68 -74 degress, for example, there is not as much...
  8. Thread: pump down

    by tonydykes55
    Replies
    19
    Views
    773

    I see. When you say "flood back from the...

    I see. When you say "flood back from the evaporator", are you saying that without a LL solenoid, in the off cycle, as a system equalizes, liquid from the condenser migrates to the evap? And then...
  9. Thread: pump down

    by tonydykes55
    Replies
    19
    Views
    773

    pump down

    Why does freezers use a LL solenoid / pump down to kill the compressor
    via a low pressure switch rather than simply put the t-stat in series with the coil ?
    I know there is a logical reason.
  10. Replies
    2
    Views
    244

    freezer vs cooler controls

    What specifically is different in a freezer and cooler controls?
    Is it mostly in the charge / pressures?
    Defrost circuit?
    TXV?
  11. Replies
    10
    Views
    467

    People are fanning themselves, because they are...

    People are fanning themselves, because they are hot in the summer months.

    Since there are many live performances, there is a heavy lighting load on the stage - Many lights. Some vendors
    bring...
  12. Replies
    10
    Views
    467

    I will have to measure return grates, they are...

    I will have to measure return grates, they are appx. 2 1/2 to 3 ft. wide X 3 1/2 to 4 ft. tall. (not sure ???)
    Could be 2' X 3' ??? I will let you know.
    I don't think there is any make up air....
  13. Replies
    10
    Views
    467

    This theater has shows via a pull down screen....

    This theater has shows via a pull down screen. However it has a large stage - mostly live performances. No supply air on the stage. Maybe he (the owner) made a mistake by blocking off the high...
  14. Replies
    10
    Views
    467

    Supplemental Heat in Theater

    I have a customer who owns a very old theater with 2 - 30 ton rooftops. Old units. Historic building.
    Massive return air plenums - Air Handlers in the attic - one on each side of the stage....
  15. Replies
    30
    Views
    3,904

    I know this thread is long overdue. I have not...

    I know this thread is long overdue. I have not been back on this site for a few months. I was to the point of evacuating, changing the txv, and weighing in a new charge -
    as a last ditch effort....
  16. Replies
    30
    Views
    3,904

    I have not solved the problem yet. I have been...

    I have not solved the problem yet. I have been overloaded with work. Temp is holding at 20. I went back Friday morning and adjusted the charge. The suction was 46. I managed to get it down to 36 and...
  17. Replies
    30
    Views
    3,904

    I found a schematic. Very old I managed to piece...

    I found a schematic. Very old I managed to piece it together and make a copy. It's pretty legible, but it does not show
    the LL solenoid or indoor stat. I've seen some that have the indoor stat...
  18. Replies
    30
    Views
    3,904

    walk in freezer controls

    I am still learning about the controls on walk in freezers and coolers. I'm servicing one that is very old.
    the evap sometimes freezes. I have been in my school books trying to understand the...
  19. Replies
    10
    Views
    783

    Lowes doesn't sell without install. Population...

    Lowes doesn't sell without install. Population about 50K +. I'm researching this. Never heard of ducane or lennex. I will check it out. That's Lennex, not Lennox?
  20. Replies
    10
    Views
    783

    Monopolies on name Brands

    We have a local Service Company/Dealer. They sell & install Trane units. Of course they service all brands since they are a "Service Company". They do not sell to anyone but their customers/clients....
  21. Replies
    18
    Views
    1,234

    correction, I meant "open the valves" not the...

    correction, I meant "open the valves" not the gages
  22. Replies
    18
    Views
    1,234

    If it's very slow and hard to find, I pressurize...

    If it's very slow and hard to find, I pressurize both coils and then close both valves. When I come back I can tell if the evap has a leak. then I open valves and pressure will either drop or rise,...
  23. Replies
    15
    Views
    1,528

    tank has a valve on the bottom and when I...

    tank has a valve on the bottom and when I depressed it - nothing - no water, no air.
  24. Replies
    15
    Views
    1,528

    I see. simple enough. I am headed out to check it...

    I see. simple enough. I am headed out to check it out. ill repost later
  25. Replies
    15
    Views
    1,528

    exactly what is the purpose of the expansion tank

    exactly what is the purpose of the expansion tank