Leaky evap coils are famous these days
Leaky evap coils are famous these days
-
01-03-2013, 12:00 AM
- Replies
- 27
- Views
- 2,285
The outdoor TXV is stuck open, you can try...
The outdoor TXV is stuck open, you can try putting the bulb in ice water to see if TXV closes and also putting the bulb in hot water to see if it opens. Watch your suction pressure. You need to...
-
01-02-2013, 09:57 PM
Thread: "water hammer" in line set
by Huntinwalkerstyle- Replies
- 13
- Views
- 992
At 50 degrees outside there is no load on...
At 50 degrees outside there is no load on equipment and pressures will be off in cooling mode. The proper way to charge heat pump is to recover the refrigerant and weigh in the factory charge. But...
-
01-02-2013, 09:31 PM
- Replies
- 27
- Views
- 2,285
Check the Discharge line temp outside the outdoor...
Check the Discharge line temp outside the outdoor unit. If extremely hot like in the 200's the outdoor TXV is bad. I had a armstrong unit do the same thing. Run fine in cooling but in heat i had...
-
08-30-2012, 09:05 PM
Thread: York
by Huntinwalkerstyle- Replies
- 11
- Views
- 700
Trane does make a good unit, for all you trane...
Trane does make a good unit, for all you trane lovers
-
08-30-2012, 09:02 PM
Thread: York
by Huntinwalkerstyle- Replies
- 11
- Views
- 700
York themselves don't advertise its the dealers. ...
York themselves don't advertise its the dealers. Im a york dealer and i have to say what few problems we have with them york backs us 100% not like crappy trane. We use to be a trane dealer to but...
-
07-17-2012, 08:04 PM
Thread: LRA
by Huntinwalkerstyle- Replies
- 10
- Views
- 661
The LRA on the plate is what that compressor is...
The LRA on the plate is what that compressor is tested at. I have seen alot of units run past that rating but not very long.
-
07-17-2012, 08:01 PM
Thread: LRA
by Huntinwalkerstyle- Replies
- 10
- Views
- 661
If compressor is pulling LRA then it needs to be...
If compressor is pulling LRA then it needs to be replaced.
-
07-17-2012, 07:29 PM
Thread: Good story for you guys
by Huntinwalkerstyle- Replies
- 25
- Views
- 1,545
He's old school
He's old school
-
07-16-2012, 09:00 PM
Thread: Reversing valve
by Huntinwalkerstyle- Replies
- 16
- Views
- 1,079
I have seen 10 to 16 degrees at 6 inches from...
I have seen 10 to 16 degrees at 6 inches from body.
-
07-16-2012, 08:58 PM
- Replies
- 7
- Views
- 587
I agree over 150 ohms and replacing.
I agree over 150 ohms and replacing.
-
07-16-2012, 08:29 PM
Thread: just don't seem right
by Huntinwalkerstyle- Replies
- 14
- Views
- 750
Is it the right evap piston for that outdoor unit
Is it the right evap piston for that outdoor unit
-
07-15-2012, 09:37 PM
Thread: Low Subcooling Low Superheat?
by Huntinwalkerstyle- Replies
- 28
- Views
- 3,278
TXV problem
TXV problem
-
07-15-2012, 09:33 PM
Thread: york
by Huntinwalkerstyle- Replies
- 6
- Views
- 492
Sounds like its over charged
Sounds like its over charged
-
07-15-2012, 07:26 PM
- Replies
- 27
- Views
- 2,898
Its a matter of time before it fails
Its a matter of time before it fails
-
07-15-2012, 07:24 PM
- Replies
- 27
- Views
- 2,898
If its pulling high amps then condemn the...
If its pulling high amps then condemn the compressor
-
07-15-2012, 05:16 PM
Thread: Manifold hoses
by Huntinwalkerstyle- Replies
- 24
- Views
- 1,612
Just experience using different hoses
Just experience using different hoses
-
07-15-2012, 05:09 PM
- Replies
- 27
- Views
- 2,898
What is the LRA and what is the compressor rated...
What is the LRA and what is the compressor rated at? 30 plus amps sounds high in a 5 ton system.
-
07-15-2012, 04:58 PM
Thread: Manifold hoses
by Huntinwalkerstyle- Replies
- 24
- Views
- 1,612
Yellow jacket makes ball valve end hoses, they...
Yellow jacket makes ball valve end hoses, they are very nice. I think RE Michel sells them for $120.00
-
07-15-2012, 04:55 PM
Thread: Manifold hoses
by Huntinwalkerstyle- Replies
- 24
- Views
- 1,612
I used yellow jacket low loss hoses and had...
I used yellow jacket low loss hoses and had trouble with the high side too. I think the low loss ends are not made for anything above 325psi. I use there ball valve ends now and no problems
-
07-14-2012, 07:24 PM
Thread: Start Capacitor Failure
by Huntinwalkerstyle- Replies
- 5
- Views
- 798
Is the compressor pulling high amps on start up? ...
Is the compressor pulling high amps on start up? Double check the wiring at the current sensing relay.
-
07-14-2012, 10:33 AM
Thread: mini-split indoor units
by Huntinwalkerstyle- Replies
- 19
- Views
- 1,559
Mitsubishi makes a flush ceiling mount air...
Mitsubishi makes a flush ceiling mount air handler unit
-
07-13-2012, 11:02 PM
Thread: mini-split indoor units
by Huntinwalkerstyle- Replies
- 19
- Views
- 1,559
Maybe a window unit
Maybe a window unit
-
07-13-2012, 10:59 PM
Thread: Motor Temperature
by Huntinwalkerstyle- Replies
- 25
- Views
- 1,594
I have seen 115 to 125 degrees at about 95...
I have seen 115 to 125 degrees at about 95 degrees outside
-
07-13-2012, 09:52 PM
- Replies
- 39
- Views
- 2,651
You add refrigerant to raise subcool and remove...
You add refrigerant to raise subcool and remove refrigerant to lower subcool