09-08-2009, 09:56 PM
Thread: FX Server Software
by mikey_9- Replies
- 9
- Views
- 567
Is this that querk where the user needs to be...
Is this that querk where the user needs to be administrator on the local machine (not a network user)?
-
09-07-2009, 11:21 PM
Thread: server room auto dialer
by mikey_9- Replies
- 9
- Views
- 1,068
We make these inhouse. ...
We make these inhouse.
http://www.planetcontrols.com.au/products.php?content=crems
Comes with 4 hour battery backup, 24VDC/AC powered, SMS, Email, SNMP, etc. Not sure how it goes price wise or... -
08-04-2009, 04:04 AM
- Replies
- 39
- Views
- 2,457
Can I bother you for 1 also? :)
Can I bother you for 1 also? :)
-
Are you using the NRM? In Oz the NRM is way...
Are you using the NRM? In Oz the NRM is way expensive ($100AUD +) so I altered the program to take a 1KNi sensor with a push button for After Hrs or a 10K sensor configurable with the MUI.
It... -
07-27-2009, 05:54 AM
Thread: AX Email Through Exchange?
by mikey_9- Replies
- 7
- Views
- 496
I did this the other day..Check out the Help in...
I did this the other day..Check out the Help in workbench. Its a bit obscure but manageable. :D
-
07-25-2009, 05:28 AM
Thread: Green Bldg Cert/Energy Cert.....
by mikey_9- Replies
- 25
- Views
- 1,063
Man, I thought NAtive BACNET was peer to peer. I...
Man, I thought NAtive BACNET was peer to peer. I was commenting on this to a Delta Tech and he told me that Delta was P2P. :confused:
-
07-22-2009, 07:23 AM
Thread: Standalone FX-07
by mikey_9- Replies
- 3
- Views
- 317
You'll need FX builder to configure the program. ...
You'll need FX builder to configure the program. Setting up the scheduling is very messy.
-
07-22-2009, 07:02 AM
Thread: AX to Outlook
by mikey_9- Replies
- 14
- Views
- 763
Why not try to re-educate them into using the...
Why not try to re-educate them into using the schedule for the room as the reservation system rather than Outlook? :confused:
-
07-13-2009, 03:11 AM
Thread: String Conversion
by mikey_9- Replies
- 5
- Views
- 331
I'm thinking it should be an enum also...
I'm thinking it should be an enum also...
-
07-13-2009, 03:04 AM
Thread: Carrier GX30 Chiller Modbus Registers
by mikey_9- Replies
- 4
- Views
- 1,631
Thanks heaps. :)
Thanks heaps.
:) -
07-05-2009, 09:27 PM
Thread: Carrier GX30 Chiller Modbus Registers
by mikey_9- Replies
- 4
- Views
- 1,631
Thanks
Thanks
-
07-05-2009, 08:49 PM
Thread: Carrier GX30 Chiller Modbus Registers
by mikey_9- Replies
- 4
- Views
- 1,631
Carrier GX30 Chiller Modbus Registers
I have a Carrier 30GX chiller with a HLI into a Trend XNC. The Trend has died and I have a Jace6 (FX-60) on site. I have been trawling the internet I have found that the chillers came with a RS485...