  1. Replies
    44
    Views
    4,293

    Correct...but i really think theres a problem in...

    Correct...but i really think theres a problem in the board.Im thinking if there is a voltage drop its probabley in the board...SWAG approach...
  2. Replies
    44
    Views
    4,293

    We are currently in the process of just wiring...

    We are currently in the process of just wiring everything in a more mechanical fashion...will see what happens...kinda like the older model Traulsen reach ins
  3. Replies
    44
    Views
    4,293

    This unit has a split evap with 2 txv's...way...

    This unit has a split evap with 2 txv's...way more complicated then it needs to be.Traulsen is way more simple...
  4. Replies
    44
    Views
    4,293

    Timebuilder to answer your question this unit...

    Timebuilder to answer your question this unit does pump down...it has a LLS...
  5. Replies
    44
    Views
    4,293

    Delfield 3 dr reach in model # SLF72-S serial...

    Delfield 3 dr reach in model # SLF72-S serial #397171-T....its diffecult to test head pressure on second start up cause it dont stay on long enough cause it hums and trips breaker.There fore...
  6. Replies
    44
    Views
    4,293

    Sorry been busy...i will post model # and serial#...

    Sorry been busy...i will post model # and serial# today
  7. Replies
    44
    Views
    4,293

    Basically what's happening is unit runs nd starts...

    Basically what's happening is unit runs nd starts fine.I can here it pump down then shuts off comp.Whem it cycles back on the comp tries to start,hums and trips breaker.I have even unplugged it...
  8. Replies
    44
    Views
    4,293

    I want to thank all of you for your time on your...

    I want to thank all of you for your time on your input.I have considered a voltage problem and also a chance of the comp trying to start on high head pressure.I have tried it on separate circuit and...
  9. Replies
    44
    Views
    4,293

    I'm thinking it might be the valve cause after a...

    I'm thinking it might be the valve cause after a short time the compressor (semi hermetic) starts with no problem.Then pulls down shuts off then when I goes to start hums a trips breaker.It also has...
  10. Replies
    44
    Views
    4,293

    Yes it has LLS valve...it's a three door...

    Yes it has LLS valve...it's a three door commercial freezer
  11. Replies
    44
    Views
    4,293

    Delfield freezer

    I have a Delfield freezer I'm working on.Its a 404A system.When I got to the call I found a tripped breaker.I reset the breaker and it started no problem.I proceeded to take my pressures and temps.I...
  12. Take an hvac electric fundamentals class at a...

    Take an hvac electric fundamentals class at a community college or a trade school...They help...when i first started i didnt know squat about electricity...it helped me a whole bunch...and yes they...
  13. Replies
    4
    Views
    376

    Well im not a DIY im actually in the hvac...

    Well im not a DIY im actually in the hvac trade...i just wanted some more imput thats it...not all of us are blessed with "old school guys in the field". I actually had to go to trade school to learn...
  14. Replies
    4
    Views
    376

    Advice please on change out

    I'm ready to do my own change out.I have a old 70% in a closet space.I'm unsure if I should do an attic install or install my new 80% furnace wright in the same closet space?All gas and electric...