    This is caused by residual refrigerant gas in the...

    This is caused by residual refrigerant gas in the sensor port. Next time you see this happen, gently blow a little air into the port, and you'll see the gauge go to Hi-P immediately.

    This is not...
  2. Replies
    186
    Views
    21,619

    There are not a lot of pieces....what did you...

    There are not a lot of pieces....what did you discover?
  3. Replies
    38
    Views
    2,009

    Yes, that came across quite a bit more snarky...

    Yes, that came across quite a bit more snarky than I intended. My apologies to Russell.
  4. Replies
    38
    Views
    2,009

    The zip case was specifically designed to throw...

    The zip case was specifically designed to throw over your shoulder so you can carry your other tools up the ladder at the same time. The scale needs no additional protection. I have been known to...
  5. Replies
    38
    Views
    2,009

    Hi, Anthony. I didn't see this thread until...

    Hi, Anthony.

    I didn't see this thread until today. I am the designer and manufacturer of the BluVac and the DS-220R scale. Thank you for your purchase.

    I hope you like it. If you have any...
  6. Thread: BlueVac Problem

    by joeyd
    Replies
    12
    Views
    537

    This sounds like a problem with the keypad. Call...

    This sounds like a problem with the keypad. Call me on Monday to arrange repair.
  7. Thread: BlueVac Problem

    by joeyd
    Replies
    12
    Views
    537

    klee7013, The behavior you described is not...

    klee7013,

    The behavior you described is not normal. Keep an eye on it. If it happens again, call me at my shop and I'll repair it for you. The number is on my website http://accutools.com.
    ...
  8. Replies
    32
    Views
    1,289

    I appreciate the compliment, hvac5646. Thanks!

    I appreciate the compliment, hvac5646. Thanks!
  9. Replies
    32
    Views
    1,289

    FYI, the BluVac sensor can be completely dried of...

    FYI, the BluVac sensor can be completely dried of alcohol immediately (within a few seconds) by pulling a vacuum on it.

    Also, as you said, the BluVac sensor is rated for 500psi overpressure...
  10. Replies
    32
    Views
    1,289

    Sorry, Moparmyway. The freezer trick works only...

    Sorry, Moparmyway. The freezer trick works only with the BluVac...
  11. Replies
    186
    Views
    21,619

    No, we private-label the scales for them as well....

    No, we private-label the scales for them as well. In exchange, we get access to their substantial distribution network.



    Your original suggestion is still on my white board (along with dozens...
  12. Replies
    186
    Views
    21,619

    The UEI DMG100 and DMG200 gauges are built...

    The UEI DMG100 and DMG200 gauges are built side-by-side with the BluVac and BluVac LTEs in our factory. Except for the color, they are the same.
  13. Replies
    75
    Views
    3,449

    Thanks, Gravity, but it makes no matter to me...

    Thanks, Gravity, but it makes no matter to me whether one buys a BluVac/BluVac LTE or a UEI DMG 200/100. For those who shop only at J-Mart, the yellow one is currently their only choice!
  14. Replies
    186
    Views
    21,619

    The BluVac port is a standard 1/4 male flare. It...

    The BluVac port is a standard 1/4 male flare. It should interface with pretty much all standard 1/4 female flare connections with a rubber seal. The only connectors I would stay away from are...
  15. Replies
    186
    Views
    21,619

    You may get some interference with the schrader...

    You may get some interference with the schrader depressor. If so, just pull it out.
  16. Replies
    186
    Views
    21,619

    Looks good to me.

    Looks good to me.
  17. Thread: bluvac

    by joeyd
    Replies
    21
    Views
    1,932

    Hi, Jared. It sounds like you have been...

    Hi, Jared.

    It sounds like you have been putting excessive torsion on the plastic body of the BluVac when connecting/disconnecting the gauge. Over time, this will cause the plastic to stress and...
  18. Replies
    34
    Views
    3,283

    I don't toot my own horn much, but I thought this...

    I don't toot my own horn much, but I thought this was worth sharing, especially in this thread.

    I was contacted a few days ago by a university student doing post graduate work involving deep...
  19. Replies
    34
    Views
    3,283

    A sincere 'thank you' for the compliment! ...

    A sincere 'thank you' for the compliment!



    The BluVac operates at a *very low* temperature compared to other gauges. This is one of the reasons why it has such a long battery life. The sensor...
  20. Replies
    34
    Views
    3,283

    Not entirely true. Yes, since the thermal...

    Not entirely true. Yes, since the thermal conductivity sensors are exposed directly to the atmosphere being measure, all TC base micron gauges lose accuracy over time. But, the BluVac is the *only*...
  21. Thread: Testo gauges.

    by joeyd
    Replies
    24
    Views
    2,051

    As you indicated in your correction above, 945 to...

    As you indicated in your correction above, 945 to 1055.
  22. Thread: Testo gauges.

    by joeyd
    Replies
    24
    Views
    2,051

    As you indicated in your correction above, 945 to...

    As you indicated in your correction above, 945 to 1055.
  23. Thread: Testo gauges.

    by joeyd
    Replies
    24
    Views
    2,051

    The BluVacs' rated accuracy is +/- 5% (of...

    The BluVacs' rated accuracy is +/- 5% (of reading) +/- 5 microns from 10°F to 122°F (-12°C to 50°C).

    Additionally, the BluVacs can be recalibrated to factory specifications simply by placing it in...
  24. Thread: Testo gauges.

    by joeyd
    Replies
    24
    Views
    2,051

    Hi, Ice. Looking at the Testo 557 datasheet,...

    Hi, Ice.

    Looking at the Testo 557 datasheet, it rates vacuum accuracy as +/- 1% FS (Full Scale) +/- 1 digit (at 22C).

    This is a helluva way to rate a micron gauge! I don't know what they...
  25. Replies
    26
    Views
    3,232

    You are correct, Juan. Which is one of the...

    You are correct, Juan. Which is one of the reasons the BluVac is special: you can recalibrate it to factory specifications yourself simply by placing it in the freezer.