  1. Replies
    11
    Views
    522

    Nice to see that they recommend my bandaid to...

    Nice to see that they recommend my bandaid to their piss poor design. I think the first solution I provided still results in a lot less frustration...

    Some day one of these systems will dump a...
  2. Replies
    13
    Views
    519

    You plumbers have such a great sense of humor.

    You plumbers have such a great sense of humor.
  3. Replies
    13
    Views
    519

    None that I know of here. Even at a few local...

    None that I know of here. Even at a few local unions shops, the techs are not.
  4. You may have to rethink your requirements. Any...

    You may have to rethink your requirements.

    Any of these transducers will need power to work. Either you need a 3rd source of power to supply the transducer power....or it will have to steal it...
  5. Thread: JAVA AGAIN???

    by orion242
    Replies
    9
    Views
    550

    Then.....rinse, wash, and repeat for every PC...

    Then.....rinse, wash, and repeat for every PC they use.
  6. Thread: JAVA AGAIN???

    by orion242
    Replies
    9
    Views
    550

    Did you RTFM on AX v3.8? How about the lengthy...

    Did you RTFM on AX v3.8?

    How about the lengthy thread here about it?

    You need to install some obscure java addon from a long list of files on Oracle's website to make 3.8 work. And of course...
  7. Replies
    43
    Views
    3,031

    I'm not talking about contractors stock piling...

    I'm not talking about contractors stock piling controllers, its a hell of a lot easier for a OEM to stock a few reels of a key component that is about to be EOL. A single reel can hold 1,000+ ICs...
  8. Replies
    17
    Views
    790

    LOL! Its valuable advice like this that keeps me...

    LOL! Its valuable advice like this that keeps me reading this forum.
  9. Replies
    43
    Views
    3,031

    There is little reason OS changes require a rip...

    There is little reason OS changes require a rip out and replace. The manufacture can rework and update their OWS software if they feel motivated to. Just because dos is dead doesn't mean win7 can...
  10. Thread: Fluke Connect

    by orion242
    Replies
    2
    Views
    219

    Fluke Connect

    Any use the connect software on their phone yet? Find the app useful or not?

    Looking at getting the ir3000 for my 289. Things are getting a bit more strict here with the arc flash nonsense, and...
  11. Replies
    7
    Views
    289

    I would get the local Trend guy out there to fix...

    I would get the local Trend guy out there to fix it at this point. Continuing to mess around with it is likely going to turn it into a paper weight.
  12. Replies
    7
    Views
    289

    Is there a reason your backing up the strategy? ...

    Is there a reason your backing up the strategy? Its going to be useless as far forward your attempting to go.

    You will need to upload, convert for the new firmware, and download. This backup...
  13. Replies
    3
    Views
    225

    Your a funny guy... Good luck with that.

    Your a funny guy...

    Good luck with that.
  14. Replies
    7
    Views
    289

    Better be careful or you will hose it up. use...

    Better be careful or you will hose it up.

    use IQ3 / guest for the user name password on the firmware upgrade. I would take the unit to v2 before going all the way to v3. Seems to me v2 improved...
  15. Replies
    9
    Views
    396

    You not going to... Unless you can write a...

    You not going to...

    Unless you can write a whole bacnet driver for this system.
  16. Replies
    5
    Views
    269

    They are crap, known to fail often, and a real...

    They are crap, known to fail often, and a real PITA to deal with if they didn't put the access hatch on the box.

    Do yourself and the customer a favor and recommend retro fitting them with a normal...
  17. Replies
    6
    Views
    429

    https://www.downloads.siemens.com/download?A6V1023...

    https://www.downloads.siemens.com/download?A6V10230212

    They offer exposed or concealed adjustment.
  18. Replies
    34
    Views
    1,481

    Well that half looks like crap. If it were me, I...

    Well that half looks like crap. If it were me, I would continue to divide that half at its midpoint and check again. Continue this until you find out exactly where this junk is coming from.
  19. Replies
    2
    Views
    258

    Shhhhhhht! My bots are half way through my...

    Shhhhhhht!

    My bots are half way through my l33t PW dictionary already....

    Just connecting that naked to the internet allows a handful of search engines to index it. At that point, its a target...
  20. Replies
    34
    Views
    1,481

    I would agree, using two probes is the only way...

    I would agree, using two probes is the only way to get good consistent readings and eliminate any grounding issues.

    Here is some good info on looking at bacnet waveforms.
    ...
  21. Replies
    34
    Views
    1,481

    What your calling the negative of the probe is...

    What your calling the negative of the probe is most likely earth grounded, unless your running of battery at the time. So connecting it this way is the same as grounding one leg of your trunk to...
  22. Replies
    34
    Views
    1,481

    How did you have your probe connected to the...

    How did you have your probe connected to the trunk?
  23. Replies
    11
    Views
    599

    So do you have some constructive thoughts, or...

    So do you have some constructive thoughts, or just the next plumber playing controls tech today?
  24. Replies
    11
    Views
    599

    I would have asked Mr Hutchey why the heck some...

    I would have asked Mr Hutchey why the heck some of controllers from HW previously included MOVs on the outputs and why he / HW feels the need to shove this crap on my plate now.

    While I don't...
  25. Replies
    11
    Views
    599

    ...this really grinds me. I'm sure this ME had...

    ...this really grinds me. I'm sure this ME had gotten burned by poorly designed controller and is now pushing this crap on everyone... The fact is, if your controllers die anytime lighting strikes...