  1. Replies
    4
    Views
    104

    http://www.acca.org/standards/speedsheets...

    http://www.acca.org/standards/speedsheets
    ==================================

    THAT IS WHY
    ......... I developed MY CALC
    .... SIMPLE, QUICK, VERSATILE &
    Can be used with Existing building...
  2. Replies
    4
    Views
    104

    THE DEVIL IS IN - THEE DETAILS..!..!!

    ==============
    What type of glass?
    U-factor?
    S.H.G.C.: 0.2 to 0.8?

    What is Solar Insolation Value (SIV) in each direction?
    ... THROUGHOUT THE DAY

    http://solarinsolation.org/
  3. 220 Cooling Degree Days in Seattle might...

    220 Cooling Degree Days in Seattle might translate to ONLY 180 full operating hours.
    ............................................... -------------- i.e. -- 35 DAYS for ~5 hours /day
    Local WA...
  4. http://www.nonoise.org/library/sndbasic/sndbasic.h...

    http://www.nonoise.org/library/sndbasic/sndbasic.htm#5

    Rules of Thumb

    WHEN A SOUND INCREASES BY 10 DECIBELS, THE SUBJECTIVE RESPONSE IS A DOUBLING OF LOUDNESS
    Example: 60 decibels to 70...
  5. TRANE XR14 SPEC ...

    TRANE XR14 SPEC

    https://www.trane.com/content/dam/Trane/Commercial/global/products-systems/equipment/unitary/split-systems/split-systems-1-1-2-to-5-tons/22-1765-10%204TWR40.pdf
  6. TRANE model number 4 TWR 4030 .... 4:...

    TRANE model number 4 TWR 4030

    .... 4: Refrigerant R-410A
    TWR: Heat Pump
    ....4: 14 SEER
    030: 2.5 Ton from 30,000 /12,000 = 2.5
  7. Thread: Lost my Wife

    by dan sw fl
    Replies
    143
    Views
    3,571

    May GOD & some true forms of PEACE BE WITH YOU. ...

    May GOD & some true forms of PEACE BE WITH YOU.

    I don't cry even once every year it seems,
    but this news of your loss moves me to tears.

    Sincerely, Dan

    -------------------

    Take kindly...
  8. HEAT PUMP is Required in Brandon.

    HEAT PUMP is Required in Brandon.
  9. Air flow should be > 1,000 CFM . It Very Likely...

    Air flow should be > 1,000 CFM .
    It Very Likely is sufficient because A/C system SEEMS TO BE OPERATING PERFECT.

    2.5 TON Unit is operating Very Well & meeting design values.
    102'F -74'F ...
  10. Is that a knee wall to a small attic space Where...

    Is that a knee wall to a small attic space Where it says should this be cut.?
  11. S.H.G.C. = Solar Heat Gain Coefficient = a Tint...

    S.H.G.C. = Solar Heat Gain Coefficient = a Tint index

    Updated Manual J models

    Sunrooms will generally make the system requirements much more complex.


    ATTACHMENTS
  12. Replies
    25
    Views
    638

    LOAD CALC and Electric Use

    IT APPEARS THAT YOUR ELECTRIC USE FOR COOLING & HEATING IS < 50% OF THE TOTAL USE.
    ____ < 6,700 kW of the 13,411 for the last 12 months

    The high kw/hour rate tells me your electric utility is...
  13. Replies
    25
    Views
    638

    What IS your MONTHLY Use for each of the last 24...

    What IS your MONTHLY Use for each of the last 24 months?

    i.e.
    If you are using $80 in the months Other than the cooling season,
    the cooling electric use would be $80 ( $160 June 2016 - $80 off...
  14. IF one has to ask, Maybe Not. ?..!..!!

    IF one has to ask, Maybe Not. ?..!..!!
  15. https://nest.com/support/pro/article/Help-with-ins...

    https://nest.com/support/pro/article/Help-with-installation-and-set-up#!

    Do you Still wish to install a NEST.?..??

    [ SOMETIMES, i t may come with Hornets].
  16. 46,900 BTU/HR ATTACHMENT

    46,900 BTU/HR

    ATTACHMENT
  17. Two Floors? Lots of windows .... Qty. 26 or...

    Two Floors?

    Lots of windows .... Qty. 26 or 41?
    U-Factor < 0.3?
    S.H.G.C. < 0.35?

    Without starting a Manual J calc.,
    I would have to guess Heat Loss might be in th range of 43,000 BTU/HR
  18. Sizing per ACCA MANUAL J & Operating Costs?

    1. NO.

    2. I would investigate CARRIER Heat Pump

    Heating dominant locale
    Heating & Cooling Degree Days
    . - - - - ATTACHMENT
  19. I believe the Total glass area would be nearly...

    I believe the Total glass area would be nearly 430 square feet.

    WINDOW TINTING Value (S.H.G.C.) and overhang lengths for South & West facing glass are needed.
    Additional tinting of South and West...
  20. Replies
    11
    Views
    290

    Heat strips are somewhat similar to Electric...

    Heat strips are somewhat similar to Electric clothes dryer operation.

    3-Ton, 2-stage Heat Pump with 10-KW (5kw* 2) total heat strips would be more than adequate
    for Central N.C. ( 3,500 Heating...
  21. Replies
    4
    Views
    219

    Is there a Question in that Statement.. ?

    Is there a Question in that Statement.. ?
  22. Replies
    11
    Views
    290

    My preliminary Operating Cost analysis indicates...

    My preliminary Operating Cost analysis indicates that one using 800 gallons AT ~$2,400
    would be able to heat with a heat pump and strips for ~$750.
  23. Replies
    11
    Views
    290

    DUAL FUEL IS A HUGE BENEFIT. If the system is...

    DUAL FUEL IS A HUGE BENEFIT.
    If the system is able to be very well designed and installed, the option of Heat Strips with a heat pump should be evaluated.

    N.C. has a rather mild winter...
  24. What is the "Corresponding Inside Unit ".? AHU...

    What is the "Corresponding Inside Unit ".?

    AHU - Air Handling Unit
    Carrier probably has AT LEAST a half dozen AHU options.
  25. AN INTERMITTENT A/C CONTROL ISSUE can NOT be...

    AN INTERMITTENT A/C CONTROL ISSUE can NOT be Solved via an Internet forum.

    HANDS-ON Service by Very knowledgeable Technicians = PROCESS SOLUTION
  26. HEAT GAIN ESTIMATE

    Your house might be Somewhat represented as in the Load Calc.

    ATTACHMENT
  27. A Reasonably WELL BUILT house in S FL may be...

    A Reasonably WELL BUILT house in S FL may be adequately cooled with a 4-ton system.

    I would run an independent return trunk to air handler and branch to Each bedroom. .

    How old is your...
  28. SET THE THERMOSTAT TO 75'F. The electric usage...

    SET THE THERMOSTAT TO 75'F. The electric usage may be reduced >> 30%.
  29. Calc per Manual D is probably not useful for...

    Calc per Manual D
    is probably not useful for most installed ductwork.

    Measure:
    1. Total air flow
    2. E.S.P. - External Static Pressure

    Total air flow needs to be
    1,050 CFM Minimum for ...
  30. The Rules-of-D(th)umb are applicable to a...

    The Rules-of-D(th)umb are applicable to a specific location and type of residence.
    The design process is to accurately apply the ACCA Manual J and D process
    ,,, ................. for equipment...
  31. Replies
    14
    Views
    596

    No.

    No.
  32. ACCA MANUAL J = SIZING PROCESS

    /////////////////////////////////////////////////
    2,400 SQ FOOT COLONIAL built in 1998
    Northern MA

    2.5 TON
    60,000 BTU/HR

    ATTACHMENT ...

    -------- MANUAL J -------
  33. You mean to say it is actually better to pay for ...

    You mean to say it is actually better to pay for Natural Gas instead of using "semi-free electricity" ?
  34. NEAR PERFECT ALREADY.!

    2-Ton, two Stage Heat Pump with your UA70H Dehumidifier would be Very Good selection.
    I doubt you would Actually Need a furnace. 40,000 BTU/HR modulating furnace would Much More than adequate.
    ...
  35. Replies
    6
    Views
    295

    Good windows (SHGC < 0.25, U-Factor< 0.5, V.L.T....

    Good windows (SHGC < 0.25, U-Factor< 0.5, V.L.T. > 0.45) with appropriate overhangs,
    Air Handling Unit {evaporator } + All Duct inside conditioned space,
    R- 18 Walls,
    R-30 ceiling,
    TIGHT...
  36. Replies
    6
    Views
    295

    Two zones downstairs is going to be an $,$$$...

    Two zones downstairs is going to be an $,$$$ increase.
    You may wish to pursue TRANE XR17 or similar ... about 3 ton, 2-stage downstairs.
    At 900 Square feet upstairs including an Office, the...
  37. Replies
    12
    Views
    348

    I suspect that heat gains and losses could be...

    I suspect that heat gains and losses could be larger than shown in OP #1 statement.

    BASED ON PRESUMPTIONS OF:
    ... < 20 YEAR OLD RESIDENCE
    ... Eastern NC locale

    ~ 28,000 BTU/HR

    ATTACHMENT ...
  38. Replies
    12
    Views
    348

    Furnace selection is obviously Very Poor. ...

    Furnace selection is obviously Very Poor.
    Cooling equipment selection is highly questionable.

    Apparently, you are in Eastern N.C. given a VERY LOW heating load (accurate ?)

    ZIP?
    Age of...
  39. We don't know any specifics about your _ THERMAL...

    We don't know any specifics about your _ THERMAL BUILDING ENVELOPE _ either UPstairs or the 1st Level.!..!!
    ----------------------------

    http://www.c2es.org/technology/factsheet/BuildingEnvelope...
  40. Upgrades: - All windows will be Low E-366, Argon...

    Upgrades:
    - All windows will be Low E-366, Argon gas, UF 0.26-0.29, SGHC <0.2, VLT 0.37 - 0.49
    - Air-tightness
    - New windows above
    - Attic air leaks (two options, need to choose between them)
    -...
  41. Replies
    4
    Views
    235

    http://www.hvac.com/media/manuals/specification/BR...

    http://www.hvac.com/media/manuals/specification/BRYANT226ANA036.pdf
  42. Replies
    10
    Views
    413

    47,700 BTU/HR @ 3'F with basement as noted...

    47,700 BTU/HR @ 3'F
    with basement
    as noted in ATTACHMENT
  43. Replies
    10
    Views
    413

    Radically Over-sized 30+ Years Ago

    What is Your (or previous owner) MONTHLY Natural Gas use?

    60,000 BTU/HR Furnace 90% should be adequate.
    54,000 BTU/HR Output
    ~ 1,000 CFM blower capacity.
    __ :whistle: __________
    -----------
    ...
  44. Replies
    27
    Views
    1,108

    In cathedral ceiling area, I suspect attic...

    In cathedral ceiling area, I suspect attic temperature could Easily be 40'F > Outside.
  45. Replies
    27
    Views
    1,108

    TOTAL AIR FLOW ___________ > 1,120 cfm? ...

    TOTAL AIR FLOW
    ___________ > 1,120 cfm?

    Window type?
    .. Blinds ?
    .. Tinted ?

    Improve window shading AND
    ... " ... duct to R-8.
  46. Replies
    33
    Views
    993

    Logical Enhancement to Building Envelope and Ducts

    42,230 BTU/HR; As-Is

    Moderate Renovation : 2,100 Square Feet, 2 Story
    97'F
    75'F
    45% R.H.

    Q.sensible = 29,450 BTU/HR
    with East West windows TINTED
    and R-8 Duct in Attic
  47. Replies
    4
    Views
    194

    http://www.nwclimate.org/reviews/best-digital-humi...

    http://www.nwclimate.org/reviews/best-digital-humidity-meters/
  48. Replies
    4
    Views
    194

    Typical variability might be 4%. LaCrosse Tech...

    Typical variability might be 4%.

    LaCrosse Tech has some good, Cheap hygrometers.
    However, CHEAP could mean useful life is < ~ 20 months.

    -------------------------------
    My 14 year-old ...
  49. Replies
    15
    Views
    508

    http://www3.lennox.com/pdfs/brochures/Lennox_EL296...

    http://www3.lennox.com/pdfs/brochures/Lennox_EL296E_Gas_Furnace.pdf

    What is the rated air flow for 045 furnace?
    It could be < 700 CFM.

    Given your situation,
    Without knowing the
    house size...
  50. You likely need 8 tons currently for 100'F. ...

    You likely need 8 tons currently for 100'F.

    That can be reduced to 5 tons with change in windows as stated, less infiltration and R-40 attic.
    Also, duct in attic should be R-8.

    Spray Foam on...