  1. Replies
    0
    Views
    250

    Johnson Controls condenser

    Had a no cool call on a Johnson controls condenser connected to a Johnson Controls EMS system. Found the ems was calling for 100 percent cooling. Ambient temp was in the 80s. The part that...
  2. Thread: hussman in mass

    by chr358
    Replies
    0
    Views
    143

    hussman in mass

    Thinking of going to Hussman in Mass. Anyone know how that branch is to work for?
  3. Replies
    1
    Views
    259

    Trane RTU with power exhaust wiring

    I am starting up 8 Trane RTU,s with power exhaust and trying to figure out where to land the line voltage wires coming from the power exhaust fan. I talked with Trane and they sent me a wiring...
  4. Replies
    17
    Views
    2,482

    ice machine cleaning

    I got a new job with this co and theres a lot of ice machines in restauraunts. These guys are cleaning them with chemicals without removin the ice. I have never done this. Any thoughts. I thought...
  5. Thread: low temp drop

    by chr358
    Replies
    11
    Views
    1,260

    could be a restriction. now that im looking at...

    could be a restriction. now that im looking at the numbers
  6. Thread: low temp drop

    by chr358
    Replies
    11
    Views
    1,260

    47degree suction temp 95 degree liquid ...

    47degree suction temp 95 degree liquid on circuit#1

    43degree suction and 91 degreeliquid #2
  7. Thread: low temp drop

    by chr358
    Replies
    11
    Views
    1,260

    #1 135/355 #2 125/385 410 freon

    #1 135/355
    #2 125/385


    410 freon
  8. Thread: low temp drop

    by chr358
    Replies
    11
    Views
    1,260

    I honestly didnt check for a restriction but...

    I honestly didnt check for a restriction but havin a hard time thinkin it would cause High SH and SC
  9. Thread: low temp drop

    by chr358
    Replies
    11
    Views
    1,260

    fixed orifice

    fixed orifice
  10. Thread: low temp drop

    by chr358
    Replies
    11
    Views
    1,260

    low temp drop

    was introduced to my new problem today. brand new unit. 2 cicuits. #1 15 degree SH and 12degree SC. #2 24degree SH and 21 degree SC. Only 10 degrees across coil. I would think #1 is OK but #2 having...
  11. Thread: low temp drop

    by chr358
    Replies
    2
    Views
    491

    low temp drop

    was introduced to my new problem today. brand new unit. 2 cicuits. #1 15 degree SH and 12degree SC. #2 24degree SH and 21 degree SC. Only 10 degrees across coil. I would think #1 is OK but...
  12. Thread: 404 in a car

    by chr358
    Replies
    13
    Views
    1,547

    404 in a car

    I have a car with a leak and i have a full jug or 404. Can I use the 404 instead of 134.
  13. Thread: r12 system

    by chr358
    Replies
    40
    Views
    3,833

    Ft myers. But im in boston now

    Ft myers. But im in boston now
  14. Thread: r12 system

    by chr358
    Replies
    40
    Views
    3,833

    What about the expansion valve. I can use the...

    What about the expansion valve. I can use the same???
  15. Thread: r12 system

    by chr358
    Replies
    40
    Views
    3,833

    r12 system

    I have a 3 door reach in cooler with a bad compresor. Ive never ran into this before. Whats my options as far as putting in charge
  16. Thread: which winding

    by chr358
    Replies
    33
    Views
    2,258

    I did not do a sub cool check

    I did not do a sub cool check
  17. Thread: which winding

    by chr358
    Replies
    33
    Views
    2,258

    Yes its a semi hermetic

    Yes its a semi hermetic
  18. Thread: which winding

    by chr358
    Replies
    33
    Views
    2,258

    Sorry been busy. R404 pressures 20/220 ...

    Sorry been busy. R404 pressures 20/220 cond clean new start cap run cap potential relay. amazingly box is sill working maintaining -10. but i dont think it will last. I talked to copeland...
  19. Thread: which winding

    by chr358
    Replies
    33
    Views
    2,258

    Its a self contained masterbilt. And suction...

    Its a self contained masterbilt. And suction line is insulated
  20. Thread: which winding

    by chr358
    Replies
    33
    Views
    2,258

    Yes we did.

    Yes we did.
  21. Thread: which winding

    by chr358
    Replies
    33
    Views
    2,258

    Condenser is clean. Brand new run cap, There is...

    Condenser is clean. Brand new run cap, There is an expansion valve. And super heat was 50 degrees. I no way too high. But Thanks for confiming this to me. I will call copeland tech support in the...
  22. Thread: which winding

    by chr358
    Replies
    33
    Views
    2,258

    Yes there is a start cap. they are brand new. ...

    Yes there is a start cap. they are brand new. The comp is cooling the freezer. I believe its not going to last. The comp wasalso too hot to touch when it was slid back in. Unfortunately I am the...
  23. Thread: which winding

    by chr358
    Replies
    33
    Views
    2,258

    I understand that. What I am looking for is...

    I understand that. What I am looking for is where to take the reading exactly. When I take the reading on the line going into the head its drawing 13 amps
  24. Thread: which winding

    by chr358
    Replies
    33
    Views
    2,258

    Ya ur right. Let me rephrase the question. How...

    Ya ur right. Let me rephrase the question. How many amps should I be drawing and which wire do I put my amp probe on.
  25. Thread: which winding

    by chr358
    Replies
    33
    Views
    2,258

    which winding

    I recently ran into a problem with a single stage compressor. nameplate on compressor says 9.6 rla. The readings we are getting are 5 amps on the run winding and 13 on the common. Ivealways gone...