  1. Replies
    4
    Views
    279

    Yes that is correct. I believe you could also use...

    Yes that is correct. I believe you could also use dew point. The spec I had to follow was what I had stated, but there was a second reason for the 62 degree underfloor temp. Each cubicle in this open...
  2. Replies
    3
    Views
    190

    I feel like I have spent half my life waiting for...

    I feel like I have spent half my life waiting for an iq3 to release a dropped connection to a vcnc. I also usually give up waiting and cycle power to the controller. I am guessing 10 minutes if you...
  3. Replies
    4
    Views
    279

    Typically under floor systems are designed to...

    Typically under floor systems are designed to have supply air delivered to the underfloor plenum no colder than around 62 degrees. Since a 62 degree supply air temp set point would result in poor...
  4. Replies
    31
    Views
    4,414

    Got It. Thanks!

    Got It. Thanks!
  5. Replies
    31
    Views
    4,414

    Could I get a copy of this module? I was about to...

    Could I get a copy of this module? I was about to ask how I could create global set points without access to the Vykon module but this will make things much easier.
  6. Replies
    14
    Views
    999

    Thanks for the detailed reply. It sounds like AAM...

    Thanks for the detailed reply. It sounds like AAM is much more bacnet compliant than our current line which is more of a bacnet overlay over a proprietary program. Things like bacnet loops,...
  7. Replies
    14
    Views
    999

    Thanks for the reply Osiyo. That is just the kind...

    Thanks for the reply Osiyo. That is just the kind of details I am looking for. My company may have an opportunity to become a dealer and I wanted to get the inside story from a field guy like myself....
  8. Replies
    14
    Views
    999

    Thanks for the reply. I was curious about the...

    Thanks for the reply. I was curious about the Smartones controllers. It looks like they took the aam asc controllers, put a new label on them and made them available over the counter to purchase....
  9. Replies
    14
    Views
    999

    American Auto-Matrix

    I am looking for opinions of the American Auto-matrix line of native bacnet controls. I have searched the forum on this subject, but most of the posts are from the 2009 and older era....Sage, pup,...
  10. Replies
    4
    Views
    293

    Numeric schedule

    I would use an enumerated schedule instead. You can output the numbers the same way, but you can assign facets that will display "occupied" etc. If you are connecting the schedule to a numeric...
  11. Replies
    10
    Views
    823

    Thanks for the replies. These are the older...

    Thanks for the replies. These are the older microtel boards. I put in place what willf650 suggested today and it is working well. I created my own occupied and unoccupied set points in the jace and...
  12. Replies
    10
    Views
    823

    Trane Voyager via Comm 4 Driver

    I am integrating a few constant volume trane voyagers into a jace using a comm 4 driver. These are older voyagers before reliatel boards. There are numeric writable points for occupied set points...
  13. Replies
    11
    Views
    1,145

    Thanks for this post. Glad to see some resolve to...

    Thanks for this post. Glad to see some resolve to this issue. I may try out this solution on the job I posted about that does not have the isolation relays. I've lost a few more triacs here since I...
  14. Replies
    54
    Views
    8,831

    Novar

    "Unit 1" would be the main executive module which has lost it's database. A download of the site database will need to be performed (load change download) using ess.32 software. Iscope cannot...
  15. Replies
    6
    Views
    659

    I agree. I would use an inexpensive controller...

    I agree. I would use an inexpensive controller such as a 211 or 212. It seems I was told that you can leave the address switches at 0 and it will be invisible on the network but will still act a...
  16. Replies
    11
    Views
    1,145

    Spyder and Varitrane

    I retrofitted a building with about 120 varitranes a couple of years ago using Trend's IQ-eco vav controller which looks identical to a Honeywell spyder (both made by Honeywell). I used the triacs...
  17. Replies
    9
    Views
    1,098

    Transit Connect

    I have a Transit Connect with about 40,000 miles on it. I love working out of it because I can reach everything from the back without climbing inside. I also have an extra set of shelves that are in...
  18. Replies
    13
    Views
    1,186

    Simultaneous web users

    Funny you should mention KMC. KMC was named specifically as the reason that this spec was added. Also I know that Trends web based front end is sold with the ability for three simultaneous web users....
  19. Replies
    13
    Views
    1,186

    Simultaneous Web Users in Ax

    I know. The spec is ridiculous. I posted the question on the Niagara Central and they replied that there is no limitation to simultaneous web users but the memory of the jace as well as how much...
  20. Replies
    13
    Views
    1,186

    Simultaneous Web Users in Ax

    I am trying to match a spec that requires a web based front end with an unlimited number of simultaneous web users. Does anyone know how many web users can be signed on to the web UI interface of a...
  21. Replies
    9
    Views
    3,103

    TU Service Tool

    Trane does have a free version of this software to download from their site. The software is called "Tracer Bacnet Setup Tool." It is a dumbed down version of TU Service Tool that only lets you do a...
  22. Replies
    7
    Views
    1,080

    Intellipak BCI-I

    I see that evaporator and saturated refrigerant temps are listed as read points in the BCI-I literature. I these are the ones in your spec, then bacnet integration should work.
  23. Replies
    5
    Views
    857

    Thanks for the idea. This should work. It is...

    Thanks for the idea. This should work. It is possible to write a space temperature to the intellipak as a bacnet point. If i leave the daytime warmup setpoints set at the Hi keypad, I can manipulate...
  24. Replies
    5
    Views
    857

    Trane BCI-I and Daytime Warmup

    Thanks for the reply. I suspect that the Daytime warmup terminate setpoint provided as a bacnet point is just a tease. It seems useless without the intiate point available. I feel bad telling the...
  25. Replies
    5
    Views
    857

    Any Trane experts out there?

    Any Trane experts out there?