Search:

Type: Posts; User: genesis

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    23
    Views
    857

    Quit carrying a while back before I quit running...

    Quit carrying a while back before I quit running service calls. Running service in some of the worst areas in Dallas, Houston, San Antonio, New Orleans and El Paso I would get a bit jumpy sometimes...
  2. Replies
    23
    Views
    857

    Quit carrying a while back before I quit running...

    Quit carrying a while back before I quit running service calls. Running service in some of the worst areas in Dallas, Houston, San Antonio, New Orleans and El Paso I would get a bit jumpy sometimes...
  3. Nate not sure if I am late on the subject here. I...

    Nate not sure if I am late on the subject here. I have air tested hundreds of buildings with Aircuity in the last ten years. With the advent of variable speed blowers for residential furnaces. You...
  4. Replies
    14
    Views
    585

    A T-Clip analysis needs to be preformed to remove...

    A T-Clip analysis needs to be preformed to remove liabilities for disposal of hazardous waste material as per 40CFR-T61 EPA.
    For operations your carbon media manufacture should have available life...
  5. I don't watch this site much any more surprised...

    I don't watch this site much any more surprised to see this thread brought out of the cellar. I am running air samples at the new terminal at JFK airport this week. Was checking out a surgical center...
  6. If a pure TIO2 Catalyst isn't encompassing the...

    If a pure TIO2 Catalyst isn't encompassing the entire airstream you are only oxidizing a small percentage of it. You do the math.
  7. Replies
    5
    Views
    897

    Check your PM Box I have equipment at the Kansas...

    Check your PM Box I have equipment at the Kansas City Zoo and the New Humane Society in Topeka in your area. We also have equipment at the Lackland AFB MP Canine Training Facility which is the...
  8. Over 2 million dehumidifiers recalled for fire risk

    Dehumidifiers have been linked to 46 fires, no injuries

    More than 2 million dehumidifiers are being recalled because they can overheat, smoke and catch fire.

    The Consumer Product Safety...
  9. They all work out of the box. You have to be...

    They all work out of the box. You have to be religious on you maintenance or an EAC system can do more harm than good to your HVAC system. Personally I would prefer a 4 to 6 inch Merv 13 to 16 filter...
  10. Replies
    67
    Views
    41,757

    Might check your math Teddy. At 500fpm that's...

    Might check your math Teddy. At 500fpm that's quite a distance down the duct. Just saying :.02:
  11. http://stratics.com/community/data/images/smilies/...

    http://stratics.com/community/data/images/smilies/popcorn.gif
  12. Replies
    67
    Views
    41,757

    If you have a lamp that is producing a light wave...

    If you have a lamp that is producing a light wave below 254nm you would have ozone. Most of the lamps are in the 80% range on UVC the other 20% is above 254nm to produce the blue light so you can see...
  13. Thread: IAQ Monitors

    by genesis
    Replies
    2
    Views
    554

    Tom what you should be looking at is Aircuity....

    Tom what you should be looking at is Aircuity. They have portable and permanently installed systems. Unfortunately I have never seen a sensor yet that didn't have to be calibrated over some schedule...
  14. Replies
    6
    Views
    604

    Aircuity has the Optima 500 which is portable....

    Aircuity has the Optima 500 which is portable. Check out some of the groups on Linked In
  15. Replies
    6
    Views
    604

    Spark, the Airadvice is a good option for an HVAC...

    Spark, the Airadvice is a good option for an HVAC shop the only other viable data logger out there is the Aircuity which is what we use, the also do spore trap sampling. There are many annual...
  16. Thread: IAQ Certs

    by genesis
    Replies
    6
    Views
    634

    Check IAQA

    Check IAQA
  17. Replies
    2
    Views
    779

    I hate to be the one to tell you. If you are...

    I hate to be the one to tell you. If you are laying in a surgery room all opened up. And it takes 30 to 6o minutes to oxidize MRSA, TB or C Di,f you will probably be already infected. The HVAC system...
  18. Replies
    22
    Views
    3,016

    You need to pressurize your apartment so the VOCs...

    You need to pressurize your apartment so the VOCs don't infiltrate your space.
  19. Replies
    19
    Views
    5,226

    Gentlemen UVGI lamps are an excellent selection...

    Gentlemen UVGI lamps are an excellent selection for surface irradiation. But a bad selection for IAQ. Their simply isn't enough time to deactivate a biologic moving at 500 fpm. If installed correctly...
  20. Here is an updated link. I started this post a...

    Here is an updated link. I started this post a while back.
    https://www.jstage.jst.go.jp/article/jts/35/6/35_6_929/_pdf
  21. Might ought to re think your stance.

    Bi Polar Ionization produces ions which in turn produces airborne hydroxyl radicals. These radicals attack the DNA of the contaminate. What makes you believe that they can tell the differance between...
  22. Replies
    8
    Views
    2,387

    I did one many moons ago and dropped a return in...

    I did one many moons ago and dropped a return in the space with a merv 13 filter I think I was running about 500cfm. For whats its worth its been operating like that for over 12 years with no issues.
  23. Thread: UV Lights

    by genesis
    Replies
    66
    Views
    37,003

    Irascible, well said. At 500 fpm the air is...

    Irascible, well said. At 500 fpm the air is moving 8.3 feet per second. I don't even believe a lite tan was in order. I would like to know where the 5800 micro watts seconds/cm squared came from....
  24. Replies
    29
    Views
    4,585

    I was at Trane's factory in Clarksville last...

    I was at Trane's factory in Clarksville last week. I watched them make a microchannel coil. They will be the norm in the next 5 years.
  25. The one percent can cost you more money in...

    The one percent can cost you more money in litigation that all the profits put together from the other 99%
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event