  1. Replies
    7
    Views
    485

    Check this page out on superheat and Subcooling. ...

    Check this page out on superheat and Subcooling.
    http://www.achrnews.com/articles/quick-facts-superheat-and-subcooling
  2. Thread: i'm 98%

    by Cmstech
    Replies
    153
    Views
    24,505

    Blue klein wire strippers.... 2% here

    Blue klein wire strippers.... 2% here
  3. Replies
    17
    Views
    1,148

    Fluctuation in superheat/sub cooling (assuming...

    Fluctuation in superheat/sub cooling (assuming metering device is good) would indicate non condensibles.
  4. Replies
    61
    Views
    3,409

    Need to convert using 407 refrigerant. Mo99 is...

    Need to convert using 407 refrigerant. Mo99 is junk. The older units are designed for r22, and when using mo99 which differs in capacity and pressures, the metering device doesn't meter properly....
  5. Replies
    48
    Views
    5,931

    In my bag, ratchet box wrenches 9/16 and 1/2....

    In my bag, ratchet box wrenches 9/16 and 1/2. Also stubby 7/16, 1/2, and 9/16. Anything bigger is worth a walk to the truck
  6. Replies
    2
    Views
    766

    Anyone know this company

    I'm looking for some information about a national company called Advanced Mechanical Services. Does anyone know anything about the company. They approached me with an offer today. I'm with CMS and...
  7. Replies
    10
    Views
    2,238

    Harris

    Harris
  8. Replies
    10
    Views
    2,238

    Nitrogen regulator

    I just bought this, loving it.

    http://www.harrisproductsgroup.com/en/About-Harris/newsroom/Nitrogen-Regulator.aspx
  9. Thread: Wire tracer

    by Cmstech
    Replies
    6
    Views
    2,319

    Wire tracer

    I deal with a lot of controls, and most of the systems we service are three phase. I feel like a wire tracer would save me a few headaches at times. What are some good wire tracers out there. Does...
  10. Thread: Wet/Dry Vac

    by Cmstech
    Replies
    11
    Views
    1,475

    Went ahead and bought a Shop-Vac 5gal 3hp with...

    Went ahead and bought a Shop-Vac 5gal 3hp with attachments. Not too heavy, not too bulky, and its got some good power
  11. Replies
    9
    Views
    1,876

    L Series specific, I've had smoke detectors trip...

    L Series specific, I've had smoke detectors trip the T1 trans, relays, and contactors. But my odd ball find on one particular L Series was within the wiring harness. Coming of the tb34 terminal block...
  12. Thread: Wet/Dry Vac

    by Cmstech
    Replies
    11
    Views
    1,475

    Wet/Dry Vac

    Who is making the best wet/dry vac these days.
  13. Thread: Tool bags

    by Cmstech
    Replies
    96
    Views
    16,106

    I like the way the custom leathercraft looks. I...

    I like the way the custom leathercraft looks. I may go with it since I'm up and down ladders all the time. My AWP backpack was decent up roof hatches until the strap broke
  14. Thread: Tool bags

    by Cmstech
    Replies
    96
    Views
    16,106

    Tool bags

    What brand, style tool bag are all tHe techs out there rockin? I got an AWP but it's wearing down so I'm looking at getting a new one. I was just trying to see what other guys liked/disliked. Thanks
  15. Replies
    27
    Views
    3,214

    I got the fluke 80PK-8 Type k pipe clamp, and the...

    I got the fluke 80PK-8 Type k pipe clamp, and the fluke 80PK-24 air probe
  16. Replies
    27
    Views
    3,214

    Best temperature reading tool

    What is everyone using to measure air temp?
    What is everyone using to measure surface temp?
  17. Replies
    1
    Views
    584

    Leave it to the rookie!!

    I went to an emergency call tonight on a reach in cooler at a well known restaurant. When I arrived I checked my notes and saw the new guy was just there this morning. The notes said added R-134a and...
  18. Replies
    48
    Views
    4,745

    Assuming the system (other than refrigerant...

    Assuming the system (other than refrigerant cycle) is running correctly. I would say recover refrig, blow nitro just in case TXV has debris, but It sounds like replacing the drier and charging unit...
  19. Replies
    22
    Views
    2,563

    Compressed air is a no no. All air has moisture...

    Compressed air is a no no. All air has moisture in it. I would recover R-22, blow nitro through it to get any debris out, flush my line set, replace liquid drier, nitro test for leaks, pull vacuum,...
  20. Replies
    23
    Views
    3,360

    I had on doing that a while back. It was a faulty...

    I had on doing that a while back. It was a faulty limit switch losing 24vlts to condenser fan contactor. I could tech across and it would be fine, then push on my terminals and it would read open....
  21. A tech gotta do what a tech gotta do sometimes, I...

    A tech gotta do what a tech gotta do sometimes, I hope that's just a temporary solution
  22. Replies
    14
    Views
    1,526

    I don't miss those calls. Rooftops don't sound so...

    I don't miss those calls. Rooftops don't sound so bad now lol
  23. Replies
    6
    Views
    1,193

    Went to site this morning, contacted Novar after...

    Went to site this morning, contacted Novar after pulling Novar module. No dc volts from module, status light constant not blinking. Bad Novar module. Quoted out new
  24. Replies
    14
    Views
    1,544

    TU = Trane up flow D = induced draft 2 = two...

    TU = Trane up flow
    D = induced draft
    2 = two stage
    C = 21" cabinet width
    080 = 80,000 btu
    A = design
    9 = 115 volts/ 60 hertz / natural gas
    V4= 4ton variable speed motor
    V= variable speed...
  25. Replies
    14
    Views
    1,544

    .

    .
Results 1 to 25 of 67