    Update..... Seem logical to you guys or do you...

    Update..... Seem logical to you guys or do you recognize any potential unresolved problems?

    The controls team came out to the unit this morning and looked into
    alternative control methods to...
  2. Replies
    40
    Views
    1,684

    Koolaid, the controls that were installed took...

    Koolaid, the controls that were installed took total control of the unit, even bypassing the units ability to monitor the system pressures. We fought to get the safeties directed back to the control...
  3. Replies
    40
    Views
    1,684

    Update...it seems the root cause of the problem...

    Update...it seems the root cause of the problem occurs when a few employees enter the building after hours or on Saturday and Sunday, depress the temporary occupied option on a the sensors. The...
  4. Replies
    40
    Views
    1,684

    You tell me why they would do that. Maybe the...

    You tell me why they would do that. Maybe the helper charged it? Most likely scenario that I can visualize enough liquid to prevent lubrication to destroy the bearings so quickly? I would expect the...
  5. Replies
    40
    Views
    1,684

    Yes, it has equalization line connecting the 2...

    Yes, it has equalization line connecting the 2 compressors. I lean towards the 30 lbs of refrigerant having been charged into the suction line, however I may never know for sure. Some enlightening...
  6. Replies
    40
    Views
    1,684

    It was our service manager and a helper that...

    It was our service manager and a helper that replaced the previous compressor. I believe the old compressor was open windings.
    Silfos was the solder used on the replacement compressor.
    The new...
  7. Replies
    40
    Views
    1,684

    Thanks for the reply! Suction filters are on...

    Thanks for the reply! Suction filters are on order and unit will not be ran until they are installed.
  8. Replies
    40
    Views
    1,684

    Compressor failure.

    A few of our techs replaced a compressor, and it lasted about 10 days. Then short to ground failure. Carrier 2 compressor circuit. 2nd compressor in this circuit mega ohms at 20 megs.
    Pulled...
  9. Replies
    22
    Views
    795

    My daily driver also. Only use the amp clamp, and...

    My daily driver also. Only use the amp clamp, and the temperature head. Good meter!
  10. Replies
    9
    Views
    380

    If the check valve is restricted in the indoor...

    If the check valve is restricted in the indoor unit, how does that make the suction pressure pump down? That would just ensure the refrigerant flows through the indoor metering device.
    By the way...
  11. Replies
    12
    Views
    688

    X2... My coworkers are buying a lot of Fieldpiece...

    X2... My coworkers are buying a lot of Fieldpiece now, go figure!
  12. Replies
    58
    Views
    1,512

    If they were to get paid, and at a full time...

    If they were to get paid, and at a full time position, then would not the employer be responsable for health insurance as well as pay? Would this apply to all athletes? How about the journalists that...
  13. Replies
    25
    Views
    1,135

    Horizontal evap coil installed in a vertical...

    Horizontal evap coil installed in a vertical configuration? You just may be getting more experience than you think out of this favor...
  14. Replies
    11
    Views
    971

    I think you would be better off making a resume...

    I think you would be better off making a resume and offering a company $10,000 to let you work for them for a few months.
  15. Replies
    3
    Views
    334

    Did the pressure switch get water in it? I would...

    Did the pressure switch get water in it? I would look closely at the presssure switch.
  16. Replies
    9
    Views
    659

    Don't let that valuable tool just sit there...

    Don't let that valuable tool just sit there unused. Give them a call and see about getting it repaired or replaced. Great service!
  17. Replies
    9
    Views
    659

    Talked to James today. Amazing service. Thank you...

    Talked to James today. Amazing service. Thank you Fieldpiece, I think I just might upgrade to the Sman4!
  18. Replies
    9
    Views
    659

    What happened to my SMAN3

    Charging up a heatpump, add a pound, go test register temperatures. Come back and my sale says 1lb 7oz...:eek2:...
    I Take a look at my gauge and see frost on the back.
    I guess my manifold leaks...
  19. Replies
    58
    Views
    3,230

    I do not have a boss... Only customers. I do seem...

    I do not have a boss... Only customers. I do seem to have another goat in the herd though.

    You gain customers by word of mouth. Provide timely, professional service, priced rationally, treating...
  20. Replies
    58
    Views
    3,230

    Use... The act or practice of employing someone...

    Use... The act or practice of employing someone or something
    Used...having had a previous owner
    Elite, as far as education, affirmative. Pandering, negative.
  21. Replies
    58
    Views
    3,230

    I think Benny has himself a customer loyalty...

    I think Benny has himself a customer loyalty complex. Those are MY CUSTOMERS Benny, they just currently make the check out to you. They are MY customers as the face of YOUR company.
  22. Replies
    5
    Views
    394

    Thank you.

    Thank you.
  23. Replies
    5
    Views
    394

    4twr3060a1000ab is the model. I am trying to...

    4twr3060a1000ab is the model. I am trying to learn where the defrost control sends out the 24 v that I can use to send to w2 to pull in the heat strip contactor to temper the indoor air durring...
  24. Replies
    5
    Views
    394

    Trane defrost board

    Where does a cnt 5001 demand defrost board send out a 24 volt signal that I can use to turn on the strip heat to temper the indoor air during the defrost cycle? Heading to one first thing in the...
  25. Replies
    8
    Views
    1,038

    You can pull the clip out of the top hex, and...

    You can pull the clip out of the top hex, and lift off the upper assembly. Then you can get a clear shot into the orifice with a whisker and then I use some co2 from the bottom/pilot tube assembly up...
Results 1 to 25 of 316
Page 1 of 13 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event