Search:

Type: Posts; User: thermojohn

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    58
    Views
    3,230

    As an employer, much of this thread hits home to...

    As an employer, much of this thread hits home to a dynamic that many employers face with their employees, as well as their customer base.

    I have to commend jrbenny for standing up, and speaking...
  2. Replies
    34
    Views
    2,481

    Waterfurnace nightmare!!! Help!!

    When you said Gulf Coast..... We are an hour from Pensacola, but too far away from your area.

    Really need to see what is going on to make a determination as to your problem.

    Good communication...
  3. Replies
    34
    Views
    2,481

    Where are you located?

    Where are you located?
  4. There are many many more features that an...

    There are many many more features that an iComfort stat has over any other WiFi tstat. As a dealer, I can program the blower speed from it, fine tuning it to match your heating, and cooling CFM much...
  5. Interesting... An underground home. Anyways,...

    Interesting... An underground home.

    Anyways, pressures and temps are within range for your indoor and outdoor temps. With your outdoor temp, there is just enough heat in the air to give you your...
  6. If you plan to incorporate zoning, then that is...

    If you plan to incorporate zoning, then that is the right air handler for sure.

    As I mentioned earlier, the iComfort stat is a great companion to that air handler. If you go zoning, it as well as...
  7. A CBX32 air handler, and the iComfort tstat just...

    A CBX32 air handler, and the iComfort tstat just go together like peas and carrots.

    So you got the Cadillac air handler, with the 14HPX.... Why?

    Your lockout on head pressure could involve...
  8. My Gawd, Tips..... Ass cream. :putergreet:

    My Gawd, Tips..... Ass cream. :putergreet:
  9. The bypass in a zone system is to reduce the...

    The bypass in a zone system is to reduce the noise associated with an increased air volume through a lower number of outlets. Damage caused by reducing the bypass? Not necessarily.... But how can...
  10. If that return is only for the bypass, then the...

    If that return is only for the bypass, then the filter serves only to restrict airflow. The air going into the furnace is already filtered, right?

    Most installation manuals recommend installing...
  11. Manufacturer of the zone controller? Is the...

    Manufacturer of the zone controller? Is the return with the bypass also another return from the house? Is the furnace two stage heat by chance? And lastly, the bypass damper usually (but not...
  12. Did you check this one...

    Did you check this one out? We have installed many of these with great benefit and results.

    Also agree on low RH to combat dust mites.
  13. Replies
    37
    Views
    1,345

    Joe, you can take them back..... Just dig out...

    Joe, you can take them back..... Just dig out the potato chip slurry that has gotten inside them, and try for a full refund. :grin2:
  14. Replies
    9
    Views
    681

    Requires 24 hrs sitting idle to indoor temp at...

    Requires 24 hrs sitting idle to indoor temp at 70*, if it has been operating.
  15. Replies
    17
    Views
    553

    Well, many will have varying opinions on RH...

    Well, many will have varying opinions on RH set-point but I try to keep it at 48% or 49%. The DEH 3000 control that is used in conjunction with the Ultra-Aire units has a 3% threashold on either...
  16. Replies
    17
    Views
    553

    Whole house dehumidifier

    Well....

    I don't know who you are, and I don't know of your experience.

    There are a lot of sales gimmicky salesmen in the trade, and I certainly am not one of them. Many here who have known...
  17. Replies
    17
    Views
    553

    http://m.dictionary.com/definition/shoulder%20seas...

    http://m.dictionary.com/definition/shoulder%20season
  18. Replies
    17
    Views
    553

    Whole house dehumidifier

    Thought you were looking for input on these, and I shared what I experience, and can relate to. They work very well, and address a very real problem with tight construction.

    So your point with...
  19. Replies
    17
    Views
    553

    Nope.... The air conditioner is sized for the...

    Nope.... The air conditioner is sized for the load as always, and the DH is sized for the square ft of the conditioned space.

    The a/c handles the sensible load, and the majority of the latent...
  20. Replies
    17
    Views
    553

    Whole house dehumidifier

    We install a good number of them, and have had one in my house for 2 years.

    Installed with a separate return tied into the supply works very well. Need a backdraft damper in between the DH, and...
  21. Replies
    9
    Views
    681

    Are you in the trade? This AOP forum is reserved...

    Are you in the trade? This AOP forum is reserved for those not in the trade to ask questions.

    Right off the bat, these machines are not for DIY. What is you involvement with them?
  22. Replies
    9
    Views
    681

    The low side (r-23) circuit is always charged to...

    The low side (r-23) circuit is always charged to a static pressure.... And not while it is running like all the other refrigerants we are used to.
  23. Replies
    7
    Views
    725

    Man.... That is deep, but very true.

    Man.... That is deep, but very true.
  24. Replies
    12
    Views
    781

    It gets be not about the $$$$ anymore. Sanity,...

    It gets be not about the $$$$ anymore. Sanity, and safety are important factors too.

    Looks like its time for the Co. to invest in putting another man and a truck on the road. Growth is a good...
  25. Replies
    15
    Views
    776

    http://ecuheatrecovery.com/pages/faq.html

    http://ecuheatrecovery.com/pages/faq.html
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine