  1. Replies
    18
    Views
    906

    Looks great....Your metal always looks good. ...

    Looks great....Your metal always looks good. Does the ICP have a PSC or ECM? Have you ever used a zone handler on a zone system? They work nice instead of having to install a by-pass.
  2. Replies
    12
    Views
    557

    If you want to slow the circ. speed and the drive...

    If you want to slow the circ. speed and the drive the speed up when htg or cooling then a Fanhandler is the only way to go.
    www.fanhandler.com/
  3. Replies
    6
    Views
    1,283

    We lose more helpers that way!

    Was wiring in my A/C breaker when I saw this. How would you like to be the one to draw the short straw. I think it powers the floor sander?!!?
  4. I've been using the kick start as well KS-1 is...

    I've been using the kick start as well KS-1 is good to 5 tons
  5. Replies
    22
    Views
    1,841

    You have to where a lot of "hats" and I work long...

    You have to where a lot of "hats" and I work long hours but I don't think that I could go back to work with people that say close enough or can't see it from my house ever again.
  6. Maybe not but you could service one as soon as...

    Maybe not but you could service one as soon as tomorrow.
  7. In my area I was told the supply pressure before...

    In my area I was told the supply pressure before the regulator is 75#. Then regulated down to 7" W.C.
  8. Replies
    16
    Views
    560

    Whiskey ..... Drink it don't put it in your eyes!

    Whiskey ..... Drink it don't put it in your eyes!
  9. Replies
    16
    Views
    560

    I welded for years and had multiple flash burns....

    I welded for years and had multiple flash burns. Extreamly painful and there is nothing you can do. Flash burn is when the cornea is burned off your eye and it takes 24 hrs to regenerate
  10. Replies
    22
    Views
    1,841

    Thanks.......I do that on every furnace/coil that...

    Thanks.......I do that on every furnace/coil that I have room for.
  11. Replies
    22
    Views
    1,841

    Lol...waitng for sparky to run a wire over then I...

    Lol...waitng for sparky to run a wire over then I will wire it up.
  12. Replies
    22
    Views
    1,841

    Tape first so it doesn't indent the armor flex?...

    Tape first so it doesn't indent the armor flex? Not a bad idea I may use that. As far as the vanes they were extra but I had already figured the TEL for the system with out them.
  13. Replies
    22
    Views
    1,841

    Thank you. It's nice to be in the club.

    Thank you. It's nice to be in the club.
  14. Replies
    22
    Views
    1,841

    They probably look long in the pic, but the...

    They probably look long in the pic, but the intake and exhaust are about 30' of pipe and the equivalent length of the fittings is 14'. The manual says I can go 135', plus I have found if I keep the...
  15. Replies
    22
    Views
    1,841

    The new energy code......ducted supply AND return.

    The new energy code......ducted supply AND return.
  16. Replies
    22
    Views
    1,841

    Thank you. The idea for the riser is better air...

    Thank you.
    The idea for the riser is better air flow and for me an easy place I can check the heat exchanger from above. I also put turning vanes in the return elbow before the filter and a...
  17. Replies
    22
    Views
    1,841

    New Bryant Evolution Zone System

    This is a new construction house. It is zoned upstairs/downstairs. It will be getting the connex wi-fi control when the painters leave and a smart sensor for upstairs. One of the challenges on...
  18. With more people circulating the fan I think it's...

    With more people circulating the fan I think it's more benifical to have the grill at the top. Pulls warm air in the winter off the ceiling and circulates it. Summer it pulls warm air and conditions...
  19. If I can get a bigger grill say it was a 14x6 and...

    If I can get a bigger grill say it was a 14x6 and I can make it a 14x10 I will do that but I was just a 2 recent jobs where all the base grills were covered by furniture. TESP was 1.3" after I move...
  20. Yes I have moved grills up and on new...

    Yes I have moved grills up and on new construction I put the return high. It has a couple of benefits.
    1- I will increase the grill size for better air flow/ less noise. Typically the base return...
  21. Replies
    18
    Views
    1,128

    X2 I try to learn ahead of the problem so I know...

    X2 I try to learn ahead of the problem so I know what to do when it happens.
  22. Replies
    22
    Views
    994

    X3

    X3
  23. Replies
    18
    Views
    1,002

    A common mis conception is the friction rate #'s...

    A common mis conception is the friction rate #'s are static press. Very few people know how to use the ductulator properly.
  24. It makes more sense than a modulating furnace!...

    It makes more sense than a modulating furnace! I'm not old school and I like the concept of a modulating furnace but if you put a combustion analyzer on a mod you would have a different opinion. I...
  25. Thread: Brazing

    by perfectionist
    Replies
    25
    Views
    1,308

    [QUOTE=mario tonzelli;18011401]Flow meter I have...

    [QUOTE=mario tonzelli;18011401]Flow meter I have and I try to keep the pressure at a min. It does make sense that the gas has to vent .As an example , Your installing a new system . You have your...