  1. Replies
    18
    Views
    15,364

    Hi travis, I too would be interested in a copy if...

    Hi travis, I too would be interested in a copy if possible, my email is in my profile.

    Thanks
    Dazza
  2. Replies
    119
    Views
    16,087

    There is also a V2 Easyio30P that has a better...

    There is also a V2 Easyio30P that has a better processor and more memory; it can easily recognised by a blue run light instead of green.

    My experience is that using the modbus comms on the...
  3. Replies
    47
    Views
    6,915

    Yes you would have to replace it, noone is going...

    Yes you would have to replace it, noone is going to develop a programming tool that can miraculously program anyones devices from the past but moving forward I would epect all players will develop...
  4. Replies
    47
    Views
    6,915

    This is exactly where the Sedona framework comes...

    This is exactly where the Sedona framework comes in; 1 tool (I mean software tool not the person programming is a tool )to program multi vendor products. I dont even have to use a Jace with my...
  5. Thread: Sedona framework

    by azzad
    Replies
    4
    Views
    1,257

    Its not what I would call programming its more...

    Its not what I would call programming its more configuring, you get menu's with the different types of functions, each function is numbered and each input/output/parameter is numbered.

    You then...
  6. Thread: Sedona framework

    by azzad
    Replies
    4
    Views
    1,257

    EasyIO are great controllers they have 3 differnt...

    EasyIO are great controllers they have 3 differnt firmware files (Bacnet, Modbus or Sedona). With the Modbus firmware they can be programmed with a web browser; this is how I started using them. I...
  7. Replies
    7
    Views
    1,216

    IMHO there is no way of acurately estimating...

    IMHO there is no way of acurately estimating savings without studying how the system operates now.

    My bean counters have asked me to do the same thing numerous times and I will never give them...
  8. Replies
    11
    Views
    1,350

    Hi, first things first you need a seperate power...

    Hi, first things first you need a seperate power supply for the 7798 and the SCU.

    Your address on the SCU is 5.
    You need DIP sw 6 on to have double address mode

    Have you loaded a bin file to...
  9. Thread: First Bacnet

    by azzad
    Replies
    47
    Views
    3,492

    I have just read through this thread and I got...

    I have just read through this thread and I got caught out with the exact same thing with the modbus card on the Johnson/Eaton VFD. The + and - terminals are back to front.

    I worked it out whils...
  10. Thread: TCP/IP

    by azzad
    Replies
    46
    Views
    3,834

    I have just installed some 50 odd Sedona...

    I have just installed some 50 odd Sedona controllers that are all IP based. We ran in a new standalone network and all necessary infrastructure to support it.

    Dazza
  11. Replies
    31
    Views
    1,969

    I didnt even thik of those at CSI we used a...

    I didnt even thik of those at CSI we used a sensor that they called a lini-temp and I believe it was something very similar to the item suggested by Bob.

    Dazza
  12. Replies
    31
    Views
    1,969

    I am not sure if I have missed something but is...

    I am not sure if I have missed something but is there a reason why you decided you couldnt use a 0-10v DC temperature sensor instead?

    Dazza
  13. Replies
    31
    Views
    2,687

    Rellufnalla/Crabmaster This is the kinda thing...

    Rellufnalla/Crabmaster

    This is the kinda thing I intend on setting up, I just need to chase up the tower design information.

    Dazza
  14. Replies
    31
    Views
    2,687

    Its not likely I will ever get 12C condensor...

    Its not likely I will ever get 12C condensor water anyway but I can certainly relate the tower setpoint to chilled water entering.

    This is a variable orifice machine as well.

    Have you done...
  15. Replies
    31
    Views
    2,687

    I understand the differance but that type of...

    I understand the differance but that type of system is extremely rare here; hence the question.

    Dazza
  16. Replies
    31
    Views
    2,687

    I had it verbally confirmed again today, I have...

    I had it verbally confirmed again today, I have asked for it in writing, from the supplier/manufacturers "engineer" that 12C water is optimimum for this machine?

    Dazza
  17. Replies
    31
    Views
    2,687

    What has fee cooling and mechanical cooling got...

    What has fee cooling and mechanical cooling got to do with a cooling tower?

    I have seen a few systems where the cooling tower is coupled to the chw loop through a heat exchanger as the first stage...
  18. Replies
    31
    Views
    2,687

    I dont understand the logic behind this for a...

    I dont understand the logic behind this for a cooling tower. Dewpoint can be very important for chilled water temperature so you are not dehumidifying at your cooling coils; but that is a different...
  19. Replies
    31
    Views
    2,687

    This is exactlly what I am trying to avoid and...

    This is exactlly what I am trying to avoid and now that I have sensors setup and am logging wet bulb I agree there is no chance I will achieve wet bulb.



    Its an old Muller tower which I believe...
  20. Replies
    31
    Views
    2,687

    Its a York YK 1550 kW with VSD, VGD, IGV and hot...

    Its a York YK 1550 kW with VSD, VGD, IGV and hot gas bypass ;)

    I was categorically told the lower the condenser water temp the better and that 12 was considered the minimum.

    But going on the...
  21. Replies
    31
    Views
    2,687

    What I have been told is the colder the better...

    What I have been told is the colder the better and going on the design data that has been provided at different condensor water temperature they are correct.

    Dazza
  22. Thread: Oscilloscope

    by azzad
    Replies
    17
    Views
    2,277

    What about one of these?...

    What about one of these?

    Sainsmart DSO0203

    Dazza
  23. Replies
    25
    Views
    6,039

    CSI was merged with TAC some time ago and is now...

    CSI was merged with TAC some time ago and is now owned by Schneider Electric.

    The Inet product is still actively sold and supported in my part of the world.

    What experiance do you have with BMS...
  24. Replies
    8
    Views
    829

    Check out Infocon's EasyIO30P, great value for...

    Check out Infocon's EasyIO30P, great value for money controller, that can be programmed with sedona or direct via a web browser.

    Dazza
  25. Replies
    31
    Views
    2,687

    Efficient Cooling Tower Control

    I am after others thoughts on efficient cooling tower control. I have a chiller that the manufacturers tell me can handle down to 12 C condensor water. When I installed the chiller I added VFD...