    I see the problem with inexperienced techs...

    I see the problem with inexperienced techs replacing a muffler with a filter/drier, but I was not aware that a hot gas line muffler could could remove moisture/contaminants.
  2. Replies
    65
    Views
    2,393

    Filter/drier in a hot gas line? Muffler in a...

    Filter/drier in a hot gas line? Muffler in a liquid line? I've never seen either of those... There shouldn't be any confusion if you know which line you're looking at right?


    Sent from my iPad...
  3. Why the condensate trap on the positive side of...

    Why the condensate trap on the positive side of the fan? Is that code where you are? Also, is that the furnace power plugged into the wall outlet?


    Sent from my iPad using Tapatalk
  4. Replies
    33
    Views
    3,246

    You know what they say... "The bigger the glob,...

    You know what they say... "The bigger the glob, the better the job..."
  5. Service Tech needed - Indianapolis, Indiana area

    CH Mechanical is a small HVAC and plumbing company looking to hire a full time service technician in the Indianapolis, Indiana area. Candidates must have 5 - 10 years experience running service for a...
  6. Replies
    5
    Views
    490

    I don't see any indication in the manual whether...

    I don't see any indication in the manual whether this is acceptable or not.
  7. Replies
    5
    Views
    490

    I agree that two stage would be better. However,...

    I agree that two stage would be better. However, I know the customer is trying to do the job as cost effectively as possible and if I submit a bid that is much higher than the other bid (adding a...
  8. Replies
    5
    Views
    490

    Trane 20 ton condenser

    Hey guys,

    I have a customer who wants me to replace a Trane R-22 20 ton condenser. The current setup is a single tin can compressor piped to a "two stage" evaporator. The suction and liquid tubing...
  9. Good point! It's amazing how many techs do not...

    Good point! It's amazing how many techs do not know this. The easiest way to see if a condenser is dirty to to feel the airflow with your hand. It's also amazing to me how many "techs" do not know...
  10. Replies
    21
    Views
    2,469

    Hey guys, at least he did one thing right - he...

    Hey guys, at least he did one thing right - he put a street 90 at the end of the vent (because it sticks out clear to the street).
    :patriot:
  11. Replies
    13
    Views
    4,619

    No, I used rigid s lock but I turned the rigid...

    No, I used rigid s lock but I turned the rigid side to the inside of the duct. I like the way it looks and I think its easier to seal. I don't usually do it on the supply duct (for obvious reasons)...
  12. Replies
    14
    Views
    2,135

    Looks familiar...

    I had a customer with a Carrier that looked kind of like this, only not as bad. (Also, it was an upflow.) The rollout switch would only open only on occasion, even though it was severely rolling out....
  13. Replies
    13
    Views
    1,477

    Alternative to limit switches

    You know, if you can't find the right limit switch, you could just instal a plain old light switch in there. That way, you could put your thermometer in one of your registers and when it gets to 120,...
  14. Replies
    13
    Views
    1,477

    Answers to your questions...

    #1. Try to reset the switch by banging it on the garage floor a couple of times. If that doesn't work, soak it in warm soapy water overnight. Be sure to let it dry before reinstalling it.

    #2. On...
  15. Replies
    13
    Views
    4,619

    The evap coil was designed with two 1-1/8"...

    The evap coil was designed with two 1-1/8" outlets for suction and two 3/8" inlets for liquid. I had to install a 1-1/8" X 1-1/8" X 1-3/8" tee in the suction line because the rest of the lineset had...
  16. Replies
    13
    Views
    4,619

    The reason for running the return duct so far was...

    The reason for running the return duct so far was primarily, ease of access to filters. This unit was in an industrial plant where they were very stringent on safety rules and cleanliness. Since the...
  17. The first line inside the box says that the...

    The first line inside the box says that the publication is for cooling-only applications.
  18. Thanks for the link, that is good information....

    Thanks for the link, that is good information. I've never seen that before. I'm going to hold onto that file. Thanks again!
  19. Replies
    6
    Views
    914

    Sometimes there is a sensor that cycles the fan...

    Sometimes there is a sensor that cycles the fan on the basis of refrigerant pressure, although they are not common on residential units. If you have one such component, on a 42 degree day, the fan...
  20. Carrier recommends 3/8"

    If I were you, I would not deviate from Carrier's installation manual. They recommends a 3/8" liquid and 7/8" suction for this unit. A smaller liquid line will almost surely give you problems. Also,...
  21. Replies
    13
    Views
    4,619

    It was either 090 or 120. I can't remember for...

    It was either 090 or 120. I can't remember for sure...it's been a while ago.
  22. Replies
    13
    Views
    4,619

    It was design build. Basically they showed me the...

    It was design build. Basically they showed me the space, and said "make something that will heat and cool this place."
  23. Replies
    13
    Views
    4,619

    First spiral duct installation

    These are pictures of my first experience with spiral duct. There's not a lot of it but I still like the way it turned out. The biggest challenge was getting it straight and level.

    The return duct...
  24. Replies
    10
    Views
    1,402

    Disconnects galore!

    I found this unit on a discount/dollar store while doing PMs. Notice that there are no less than three (count them) disconnects associated with this unit. The one that is being used is about 5 feet...
  25. Right. My mistake. The ductalator that I have at...

    Right. My mistake. The ductalator that I have at home is not the one that I am used to using in the field.

    :oops:

    Sorry for the bad info.