  1. Thread: Tool chest

    by t2
    Replies
    6
    Views
    620

    Chevy express, old school

    Chevy express, old school
  2. Thread: Tool chest

    by t2
    Replies
    6
    Views
    620

    Tool chest

    Anyone have a tool chest on there van and how did you mount it.
  3. Replies
    18
    Views
    1,001

    Anyone have a ex tech Megomhmeter

    Anyone have a ex tech Megomhmeter and if so how are they.
  4. Thread: Micron Gauge???

    by t2
    Replies
    176
    Views
    7,684

    Thermal is the way to go especially on that York...

    Thermal is the way to go especially on that York yt yk
  5. Thread: Micron Gauge???

    by t2
    Replies
    176
    Views
    7,684

    It's the only guage I trust on a 900 ton chiller

    It's the only guage I trust on a 900 ton chiller
  6. Thread: Micron Gauge???

    by t2
    Replies
    176
    Views
    7,684

    Imperial Eastman sells them

    Imperial Eastman sells them
  7. Thread: Micron Gauge???

    by t2
    Replies
    176
    Views
    7,684

    Thermal, just buy the thermal,none of the digital...

    Thermal, just buy the thermal,none of the digital ones last
  8. Replies
    5
    Views
    429

    I have a uei but nothing is better than calling a...

    I have a uei but nothing is better than calling a air balancer in.
  9. Thread: Flooded condenser

    by t2
    Replies
    4
    Views
    813

    Flooded condenser

    Single fan condensing unit with p66 fan control and sporlan lac valve. Is it ok to have both and what is the best way to charge without measuring the piping. 410a system.
  10. Thread: Mini rosebud

    by t2
    Replies
    2
    Views
    1,000

    Mini rosebud

    Anyone have the unwield mini rosebud micro 6000
    Says it does up to 1 5/8
  11. Thread: Cap n hook

    by t2
    Replies
    8
    Views
    1,586

    Will the smith fit a unwield 71 handle

    Will the smith fit a unwield 71 handle
  12. Thread: Cap n hook

    by t2
    Replies
    8
    Views
    1,586

    Cap n hook

    Anyone use a cap n hook brazing tip and how are they
  13. Thread: 10,000 ohm meters

    by t2
    Replies
    27
    Views
    2,742

    Sensors

    Sensors
  14. Thread: 10,000 ohm meters

    by t2
    Replies
    27
    Views
    2,742

    10,000 ohm meters

    What meters have a 10 k ohm scale, it seems a lot of the fluke don't
  15. Replies
    17
    Views
    1,624

    Best meter for control work

    What is the best multimeter or clamp meter for control work.
  16. Replies
    2
    Views
    617

    Tracer summit mystery

    Went on a call for a tracer summit that has been mysteriously putting voyagers to unoccupied. Customer also said they get question marks occasionally and power cycle the bcu. I found the bcu time and...
  17. Thread: a32 vs oxy

    by t2
    Replies
    9
    Views
    1,145

    a32 vs oxy

    For unsweating and brazing 2 1/8 a32 or oxy rosebud replacing a 2 1/8 discharge tee
  18. Replies
    6
    Views
    755

    Changing both compressors, I know the tee is a...

    Changing both compressors, I know the tee is a oil separator tee. If you look inside it looks orificed or bushed down. When they tried to u sweat it it snapped off. Going to call trane parts. I know...
  19. Replies
    6
    Views
    755

    Trane intellipak compressor manifold

    Is the tee in the suction manifold to tandem compressors special. I noticed it is bushed down inside . Could it be replaced with a regular tee. Can it be ordered from trane parts or do you have to...
  20. Replies
    3
    Views
    1,240

    Brush or brushless impact drill driver

    Brushed or brushless 12 v impact driver
    Looking at the Milwaukee m12 fuel vs m12 regular both are impact drivers not wrenches or drills.
    The small lithium battery would fit well in my back pack...
  21. Replies
    11
    Views
    1,464

    Johnson system technician

    What would it be like working as a systems technician for Johnson.
  22. Thread: Tracer summit

    by t2
    Replies
    1
    Views
    438

    Tracer summit

    15 ruts voyagers with reliatel none of the economizer modules have return air temp or humidty hooked up one of the rtus has diagnostics for the sensor in the more details section of the summit none...
  23. Thread: Trane yhd300

    by t2
    Replies
    0
    Views
    564

    Trane yhd300

    Newer yhd300 with reliatel tracer summit showing ra humidity and ra temp Neither sensor are wired to the Econ module. It's a trane on top of the motor not a Honeywell
    There are 15 other rtus with...
  24. Replies
    20
    Views
    2,815

    Micromanaging service manager

    Just got a new micromanaging God complex irrogant truck tracking opsessed service manager. 8 guys have walked since his invasion of a laid back profitable company. Some guys with 19 years. Was going...
  25. Replies
    27
    Views
    3,362

    Gps has ruined good company's by micromanaging...

    Gps has ruined good company's by micromanaging service managers chasing guys out the door over stopping for a coffee when the guy was out 4 hours the night before on call. The office pukes play on...
  26. Replies
    27
    Views
    3,362

    i am on my 5th company since 1997. One company...

    i am on my 5th company since 1997. One company went out of business the others had crazy turnover rates due to low pay . Been we're I am at for 10 years. The current company is obsessed with gps so...
  27. Thread: Testo died

    by t2
    Replies
    1
    Views
    861

    Testo died

    My testo 327-1 will not turn on screen just blank even when plugged in any thoughts.
    Time to send it out for service.
  28. Thread: Nice dirty boiler

    by t2
    Replies
    12
    Views
    4,551

    Lochinvar makes a cleaning kit it is a basically...

    Lochinvar makes a cleaning kit it is a basically a long drill exstenstion with a nylon brush and a cover for the rear refractory. I have cleaned a bunch of them . Combustion test it by pulling flue...
  29. Thread: Lochinvar squire

    by t2
    Replies
    1
    Views
    604

    Lochinvar squire

    lochinvar squire leaking at sensor well anyone seen this
  30. Thread: Vfd contactor

    by t2
    Replies
    21
    Views
    3,113

    The contactor would only open in a freeze stat...

    The contactor would only open in a freeze stat trip
  31. Thread: Vfd contactor

    by t2
    Replies
    21
    Views
    3,113

    Vfd contactor

    Is it ok to have a contactor inbetween the vfd and motor. This contactor would not open if there was a low limit freezestat trip otherwise it would be closed. The drive is in a mechanical rm and this...
  32. Replies
    2
    Views
    862

    Trane tracker varitrac

    When on a call for a complaint of cold air. 40 deg outside. All zones 70 to 73. Tracker calling for cooling. Hooked up labtop with software and enable supply air tempering and raised cooling...
  33. Thread: 40+year Building.

    by t2
    Replies
    28
    Views
    4,293

    If you don't know what to do with a boiler like...

    If you don't know what to do with a boiler like that then don't touch it . Things that are bad- co, explosions etc etc
  34. Thread: 40+year Building.

    by t2
    Replies
    28
    Views
    4,293

    Brush and vac boiler, change oil filter , oil...

    Brush and vac boiler, change oil filter , oil pump strainer ,burner nozzle,clean set electrodes, combustion test with testo, co,co2,draft, etc within manufactors specs. Check lwc, flame safety...
  35. Replies
    6
    Views
    742

    I had to copy and paste the dmp file in procomm...

    I had to copy and paste the dmp file in procomm and load it into the cmx.
    I don't see the occ3 value in any of the controllers files the rest off the controllers are lcx 800 . The only thing I have...
  36. Replies
    6
    Views
    742

    I got in there was a problem with customers com...

    I got in there was a problem with customers com port driver. I already have the default password. Rusty on this programming. building is a vav system with chiller steam boiler and mod con boiler. Was...
  37. Thread: Andover cmx 220

    by t2
    Replies
    0
    Views
    470

    Andover cmx 220

    Anyone still work with andovers cmx-220
    Have a building with one error light is on and can't access controller. Usually use hyper terminal or procomm . Any idea on if the service tool is still...
  38. Replies
    6
    Views
    742

    Andover cmx pro com plus

    Customer pressed the reset button on a Andover cmx. The front end has pro com plus. I sent the backup file for the cmx from pro com to the cmx. The amber receive data light is on while it receives...
  39. Thread: Round duct part 2

    by t2
    Replies
    5
    Views
    741

    I am becoming a fan of the round duct . The one I...

    I am becoming a fan of the round duct . The one I saw in the basement had the 14 to 12 trunk line close to the side wall ahu was placed a ft off wall the flex was tucked up against fl I between joist...
  40. Thread: Round duct part 2

    by t2
    Replies
    5
    Views
    741

    Round duct part 2

    Last service call I went on was a 2100 sq ft house with a 2 ton attic split and a 2 ton basement split. Both the attic system and basement system were ducted with a square to round off Ahu then 14 in...
  41. Thread: Round duct

    by t2
    Replies
    0
    Views
    391

    Round duct

    I have been seeing more round duct sytems with a square to round transition and round 16 in to 14 to 12 trunk line then saddle taps and flex runs. I guess it's better than a flex bomb 4 ft plenum...
  42. Thread: Lochinvar squire

    by t2
    Replies
    4
    Views
    577

    I knew about the thread problem but this one was...

    I knew about the thread problem but this one was from the top under the cover possibly on a weld the other 2 I noticed water on the bottom.
  43. Thread: Lochinvar squire

    by t2
    Replies
    4
    Views
    577

    Lochinvar squire

    I have come across 3 leaking lochinvar squire indirect tanks. Anyone else seen any leakers. The tanks are stainless steel.
  44. Thread: 30 ton voyager 3's

    by t2
    Replies
    10
    Views
    1,009

    30 ton voyager 3's

    My employer just picked up a maintenance contract on 30 over 30 ton voyagers by undercutting the completion . It is bid for 2 guys one day. How am I supposed to check heat exchangers in this time....
  45. Replies
    5
    Views
    1,257

    No air balance report up to customer. Could be...

    No air balance report up to customer. Could be ductwork issues
  46. Replies
    6
    Views
    651

    Maybe a blown fuse or popped transformer

    Maybe a blown fuse or popped transformer
  47. Replies
    5
    Views
    1,257

    Vav sytem airflow tracer sc

    Trane voyager vac with reliatel 18 trane vavs with electric reheat.
    Rtu runs in full economizer with return air damper shut all the time this time of year except for morning warmup. Some Boxes not...
  48. Thread: tracer sc slooowww

    by t2
    Replies
    3
    Views
    645

    Hui. I will try chrome on Monday. Laptop is...

    Hui. I will try chrome on Monday. Laptop is windows xp Internet exployer 8. Somewhere around 5 years old.
  49. Thread: Voyager vav airflow

    by t2
    Replies
    4
    Views
    738

    Voyager vav airflow

    In a vav system would cfm to the boxes be reduced if the rtu was economizing and return air damper closed. 18 vavs with electric reheat and sometimes airflow switches on 3 boxes are not making. The...
  50. Thread: Trane Package unit

    by t2
    Replies
    5
    Views
    1,061

    There is a book you can get at trane parts about...

    There is a book you can get at trane parts about voyagers. It is a black book. The voyage continues. It has some good electronic troubleshooting in it. I think it's 40 dollars.