  1. First of all you need to determine why you have...

    First of all you need to determine why you have such a large heat loss and correct that issue. Secondly, increasing the size of the unit is worthless unless the duct work is sized and installed...
  2. Yes the Greenspeed unit is considerably more...

    Yes the Greenspeed unit is considerably more money but it has an HSPF of 13 and the savings are amazing. One of our dealers installed 2 in his 5900 sq ft house and his highest bill, winter or summer,...
  3. Replies
    4
    Views
    355

    Over 40 years ago when I got into the union in...

    Over 40 years ago when I got into the union in Los Angeles I took all the tests, interviews etc. and then got a letter telling me I was number 4 on the " Caucasian" list. I called them up and said...
  4. Replies
    34
    Views
    1,368

    That is exactly the idea. Carrier wants those...

    That is exactly the idea. Carrier wants those units out of the field and is trying to make it as appealing to the ho to purchase a new unit.
  5. Replies
    34
    Views
    1,368

    Give me the model and s/n and I will tell you...

    Give me the model and s/n and I will tell you what the correct options are. Basically, if you decide on a new comp. it shouldn't cost you anything because Carrier will provide the comp., start...
  6. Replies
    11
    Views
    558

    The liq line should have been 3/8 as stated. That...

    The liq line should have been 3/8 as stated. That being said the real issue with the larger line size is the extra refrigerant in the line will cause the compressor to start under a heavier load (...
  7. Replies
    34
    Views
    1,368

    As of today (April 1, 2014 ) Carrier bulletin...

    As of today (April 1, 2014 ) Carrier bulletin SMB14-0025-1 gives the homeowner the option to have the compressor, and related start components, etc. replaced and the dealer gets $ towards the labor...
  8. Replies
    18
    Views
    1,203

    A few companies used line sets that were...

    A few companies used line sets that were corrigated at the ends to flex for installations and they were teflon lined inside. These worked ok for several years as cooling systems but, then people...
  9. Replies
    13
    Views
    827

    Carrier will not warrant it. Seen too many failed...

    Carrier will not warrant it. Seen too many failed compressors in the past couple of years when MO99 was used in dry, or repaired, units. Most techs here have taken it off their trucks and only use...
  10. Replies
    8
    Views
    611

    When the comp shuts off the high pressure is...

    When the comp shuts off the high pressure is feeding back into the shell of the compressor because the " toilet seat" or discharge flapper valve is letting the pressure flow back. Install a check...
  11. Replies
    38
    Views
    1,643

    Years ago when this was a more common issue...

    Years ago when this was a more common issue Carrier would not warrant the system unless both evap and cond unit and lineset were all replaced. Once the green slime is in the system it is almost...
  12. Replies
    23
    Views
    2,223

    Personally I would never use that crap. Heard of...

    Personally I would never use that crap. Heard of too many compressor failures afterwards. I have never had a leak in a system I could not locate and either repair or replace that component. All that...
  13. Replies
    8
    Views
    426

    If the noise is only on start up and then goes...

    If the noise is only on start up and then goes away I would say you need a cc htr. And if it is one of the Bristol comp. units I would make sure there is no floodback, especially when it shifts from...
  14. Replies
    16
    Views
    1,037

    There is a screw on the back of the H10 that...

    There is a screw on the back of the H10 that adjusts the heat sensor and you can turn it clockwise till it stops and then use it on R410. When finished, return it to its previous setting. Don't leave...
  15. Yep, wet rags AND cool gel.

    Yep, wet rags AND cool gel.
  16. Replies
    14
    Views
    1,356

    We have been selling the Truesteam units since...

    We have been selling the Truesteam units since they came out. They have made improvements that have cut down on the service calls however, if your have hard water and you ARE NOT using an RO system...
  17. Replies
    2
    Views
    827

    Charge it like you would any other system using...

    Charge it like you would any other system using either sub-cool if a txv system or superheat if a fixed orifice...or weigh it in and check both. Beware of the new r-22 some have butane/propane...
  18. Sounds like its just going into defrost and you...

    Sounds like its just going into defrost and you get cold blow. Are you sure the strip heaters are coming on during defrost? Put an amp meter on and check it.
  19. Have seen this occur before.May or may not be...

    Have seen this occur before.May or may not be something you did. Could have been a poor connection that finally lost continuity when you pressed a button or it could have just failed. Electronic...
  20. Replies
    11
    Views
    1,132

    Contact your Carrier dealer and have him install...

    Contact your Carrier dealer and have him install a mass dampner as a first step and then add vibration eliminators or pipe in an inverted U in the refrig. line if the dampner doesn't resolve it. Done...
  21. Replies
    3
    Views
    608

    The resistance should be close on all 3 legs....

    The resistance should be close on all 3 legs. Shorting any two leads simulates a short and will cause the rotor to either lock up or be very hard to rotate. Most issues with the ECM are with the...
  22. Replies
    93
    Views
    11,125

    After reading a few replies I decided not to read...

    After reading a few replies I decided not to read all of them and just jump to the end and add my 2cents worth. One of the very first things I was taught over 40 years ago was that the only way a...
  23. Have you shut the fan off and watched how the...

    Have you shut the fan off and watched how the frost forms on the coil? It should form a nice frost pattern across the coil surface and if there are areas without frost you have a restriction in that...
  24. Do you get any fault codes on your Infinity user...

    Do you get any fault codes on your Infinity user interface control? You say it is 73 degrees inside during the day when it is 90+ outside and 73 deg. at night. Sounds like the system is working okay...
  25. Thread: im in love

    by woody19
    Replies
    11
    Views
    1,225

    Threw my H10 away !!!!

    Threw my H10 away......





    after 35 years it stopped working....


    sent it in for repairs and .....