  1. Replies
    26
    Views
    3,204

    I have two.One is working in a rendering plant...

    I have two.One is working in a rendering plant for Pilgrims Pride.Smells like death in that place.Its enough to gag a maggot.The second place is working on a Kiln drier for a lumber yard.Its 160...
  2. Replies
    56
    Views
    11,785

    My thoughts exactly!well said....

    My thoughts exactly!well said....
  3. Replies
    11
    Views
    1,371

    If you want an education,I would call the Fairfax...

    If you want an education,I would call the Fairfax Co. adault education program.I went through it about 10 years ago.Its a very good program that is highly respected in the area.If you just want to...
  4. Replies
    22
    Views
    18,574

    What's the load in the space trying to be...

    What's the load in the space trying to be cooled?What is your compressor amp draw?
  5. Replies
    14
    Views
    2,266

    15% braze is for copper to copper,or copper to...

    15% braze is for copper to copper,or copper to brass W/ white brazing flux.You can use 45% with any of it.Its just cheaper to use 15%Soft solder is not suposed to be used on any refrigeration.I know...
  6. Replies
    30
    Views
    2,880

    if its a three phase system reverse any two...

    if its a three phase system reverse any two wires.Sometimes that will break them loose when they lock up.
  7. Replies
    12
    Views
    1,263

    Your post made me smile.I remember doing jobs...

    Your post made me smile.I remember doing jobs like that.Day after day of coil washing.Changing filters for weeks at a time.My advise is get a walk man and a five gallon bucket to sit on and enjoy the...
  8. Thread: R410A

    by bjefferson
    Replies
    17
    Views
    3,511

    I know that in order to install the equipment...

    I know that in order to install the equipment with 410A in it that the manufacturers are requireing that you take their course.I took a 4 hour class through York.Once you can prove that you are 410a...
  9. Replies
    15
    Views
    2,482

    chs Member Registered: Jul 2002 Posts: 226...

    chs
    Member

    Registered: Jul 2002
    Posts: 226


    Dont think you had a short of any kind. I have a "Fluke"(good brand?) meter that is OMH STUPID below 5 omhs resitance.

    Try checking the...
  10. Replies
    15
    Views
    2,482

    Are you sure you got 0 ohms and not OL?Does'nt...

    Are you sure you got 0 ohms and not OL?Does'nt make sense that you would get those readings.That unit would have been tripping the breaker.I agree that you should have repaired the burnt wire and...
  11. Replies
    13
    Views
    2,015

    trple D is good stuff.

    trple D is good stuff.
  12. Replies
    9
    Views
    6,306

    they are gas pachage units.Thanks for the input...

    they are gas pachage units.Thanks for the input though
  13. Replies
    12
    Views
    1,834

    First thing I would like to know is what took the...

    First thing I would like to know is what took the first compressor out?Was it grounded too?Sounds to me like either a voltage problem or a slugging problem.I would install some kind of phase monitor...
  14. Replies
    9
    Views
    6,306

    Have several accounts with lennox...

    Have several accounts with lennox GCS24-813-130-1Y units on the roof.Units are 10 years old or older.Have been getting calls About no cooling.Been finding the units tripped on manual reset high...
  15. Replies
    15
    Views
    2,367

    McQuay makes a decent chiller

    McQuay makes a decent chiller
  16. Replies
    6
    Views
    1,613

    years ago I worked for Dunham Bush.I had to take...

    years ago I worked for Dunham Bush.I had to take a class in brazing before I could get the job.The way the instructor told us to braze steel to copper joints is to heat the steel first.Because it...
  17. Replies
    23
    Views
    3,051

    Like I said before.Too much sub-cooling is either...

    Like I said before.Too much sub-cooling is either an over charge or a restriction somewhere in the liquid line.You see frost where the restriction is.If its just a partial restriction you may only...
  18. Replies
    23
    Views
    3,051

    That much subcooling means either overcharged or...

    That much subcooling means either overcharged or a liquid line restriction.The restriction should be obvious.There should be a frost line.could be junk in the txv.I would try to adjust the txv if its...
  19. Replies
    31
    Views
    3,148

    I have done my share of both commercial and...

    I have done my share of both commercial and residential.I aggree with some of the others.There are good and bad to both sides.Commercial has more responsability.Residential seems to cause more...
  20. everything is junk when its broke

    I work on lots of equipment.Trane has its problems like the rest.The one thing I will say about Trane is that their tech support is great.Or has been for me.I work on a large plant that has alot of...