    TAC's ASD driver has an object (labelled PSI)...

    TAC's ASD driver has an object (labelled PSI) that has to be installed in the station for PSI to work on the ASD bus.
  2. Replies
    281
    Views
    40,025

    Windows XP was the last version of windows that...

    Windows XP was the last version of windows that any software was made for Network 8000.
  3. Replies
    11
    Views
    1,115

    The K-factor is a fudge factor to get correct air...

    The K-factor is a fudge factor to get correct air flow. It will be different for identical vav boxes because of the ducting. In real life you do not find the recommended 5 to 10 duct diameters of...
  4. Replies
    10
    Views
    1,374

    Where can I find a copy of NUDL?

    Where can I find a copy of NUDL?
  5. Replies
    3
    Views
    409

    Control Man, That may all be well & good, I...

    Control Man,
    That may all be well & good, I realize all good (and not so good things) must come to an end. I don't thing my ex boss was bsing me. He tends to be a bit colorful in his descriptions....
  6. Replies
    3
    Views
    409

    Another Network 8000 Request

    I worked for an Invesys distributor 4 or 5 years ago. My new employer has a number of sites with Network 8000 & wants me to take care of them. I tried contacting the local Shneider Electric dealer,...
  7. Replies
    10
    Views
    1,149

    When I was working at Siemens I would use the...

    When I was working at Siemens I would use the following procedure.
    1. Set P to a large & probably outrageous value, I & D set to zero.
    2. Adjust P down until you get the smallest P value without...
  8. Replies
    9
    Views
    1,198

    Can't find my old CD's

    I can't find my old Insight CD's :(, I haven't worked for Siemens in a quite a while, but I was able to look up the application guide for VAV TEC's on the internet & point 58 is the point to change...
  9. Replies
    9
    Views
    1,198

    Depends on the TEC Application

    What application is the TEC using? Check the application point list. If you can change the action there will be a binary point to change the action. You should then be able to change the action from...
  10. Replies
    6
    Views
    1,337

    Probably Low On RAM

    I haven't worked on Siemens equipment in 5 years now & I haven't worked on their BACNet equipment :rolleyes: but what you describe sounds like the panel is low on RAM. The panel is probably rebooting...
  11. Replies
    13
    Views
    840

    Extra Code

    Check to see if there is an object called PSI in the R2. This is required because the ASD driver did not allow for PSI (as a second master) originally. I'm not sure if it is required for tunneling...
  12. Replies
    18
    Views
    1,235

    Your com port should be COM1 or COM2. PSI is a...

    Your com port should be COM1 or COM2. PSI is a DOS program & so can only see those 2 com ports.
  13. Replies
    7
    Views
    839

    GCM Conversion

    You might want to look at Smartware Tech. They are a TAC (formally Invesys, ect. dealer). The claim to be able to convert your GCM database to a R2 data base, for a fee of course. It would be...
  14. Replies
    7
    Views
    772

    RS-485 Driver

    Since your system originally had a GCM & the problem has been around since the UNC was installed, it could be an ASD wiring issue. When Invensys gave Tridium their specs for the RS-485 hardware in...
  15. Replies
    15
    Views
    2,307

    A Possibility

    There is a possibility you have a corrupted node table. It has been a few years since I was at Siemens but let me see if I can explain it. If any of the MEC's & PCX were added to the BLN from one of...
  16. Replies
    2
    Views
    429

    Need the point list

    You need the point list from McQuay. Alerton is bacnet so they do not control the points McQuay chooses to show the system. The board might be a gateway from McQuay's proprietary communications &...
  17. Thread: Siemens FLN

    by Ex-Man
    Replies
    4
    Views
    1,206

    TEC & UC's Oh My

    Siemens TECs have their programs burned into EEPROM at the factory & you can't change them. They use a points list of 0-99. Included are the TEC address, the application number, and the rest are...
  18. Too Old?

    It could be they don't want to deal with a front end as old as yours. Since you mention Powers I am guessing your front end is using at best Win95, more likely Win3.1. They may not have anyone...
  19. Replies
    281
    Views
    40,025

    Network 8000 Programming Manuals

    I have a job coming up that will be replacing 2 GCM's with Jaces using the ASD driver. I need a copys of the GCM, MicroZone2 & PEM programming manuals. Can anyone help me here. I worked for an...
  20. Replies
    7
    Views
    1,433

    In the GCM

    Everything you see on the Signal screen is happening in the GCM. You need to figure out your GCM programming to figure out what is going on.
  21. Replies
    7
    Views
    1,433

    You may be SOL

    There is nothing you can do to program the micronet controllers from Signal. The terminal program is emulating a terminal to the GCM. To program a micronet controller you need the MNET software and a...
  22. Replies
    3
    Views
    523

    What you need

    If you are connecting directly to the MicoZone II what you need is an RS-232 to RS-485 converter. You will also need a cable to convert it to a 6 conductor RJ-11 connection. If you are connecting to...
  23. Replies
    4
    Views
    827

    Try TAC

    Try your local TAC contractor. TAC bought the division that supported RobertShaw from Invensys about 2 years ago. That would be the place to start.
  24. Thread: Siemens apogee

    by Ex-Man
    Replies
    12
    Views
    1,320

    Good Luck

    Siemens is a proprietary system:nopity:. Any interfacing is through them and their gateways. The only option is if the card is set up for their FLN protocol, which I would doubt. You may be better...
  25. Thread: Siemens VFD

    by Ex-Man
    Replies
    11
    Views
    783

    Keep Hoping

    I took care of a site, in another life, that had Siemens VFD's installed. In the 2 years I was there 3 were replaced and at least 2 others before I got there. So all I can tell you is keep...