09-06-2012, 01:10 PM
Thread: EPA Reward
by maustin- Replies
- 13
- Views
- 1,970
Poll: Do you work for the county and their operation is...
Do you work for the county and their operation is being checked or is the county conducting the investigation? Either way as long as you have your log book you should be good to go.
-
05-08-2012, 01:46 PM
Thread: Danfoss VLT Micro drive
by maustin- Replies
- 3
- Views
- 918
Thanks, looks like a good source for replacements...
Thanks, looks like a good source for replacements too.
-
04-25-2012, 05:49 PM
Thread: EPA Reward
by maustin- Replies
- 13
- Views
- 1,970
Poll: I spoke with an EPA compliance agent last year....
I spoke with an EPA compliance agent last year. He told me that the EPA is "disinterested" in pursuing reports of venting. The effort they do put forth on the subject is directed toward appliance...
-
04-17-2012, 05:40 PM
Thread: Torque spec for york
by maustin- Replies
- 3
- Views
- 556
75 if its 3/4" studs.
75 if its 3/4" studs.
-
03-19-2012, 01:45 PM
Thread: Modified Hussmann TD System - Current
by maustin- Replies
- 21
- Views
- 2,396
How about the Dolphin? Is it working?
How about the Dolphin? Is it working?
-
03-01-2012, 06:06 PM
Thread: Signal generator?
by maustin- Replies
- 10
- Views
- 921
Check with Mitchell Instruments, they have a line...
Check with Mitchell Instruments, they have a line of process loop calibrators.
I picked up one of their low end units, $400, and it works great to provide either a 0-10V or 4-20 ma signal.
You... -
01-28-2012, 06:39 PM
Thread: pneumatic compressor
by maustin- Replies
- 5
- Views
- 393
There is likely an alternating relay. If so then...
There is likely an alternating relay. If so then the pressure switch with the higher setpoint will normally operate the alt relay and thus the starter for the lead compressor. If the lead compressor...
-
10-18-2011, 09:48 AM
Thread: Operation Theater Room Spesification
by maustin- Replies
- 9
- Views
- 3,105
Try searching the VA website. They have a...
Try searching the VA website. They have a comprehensive set of specs available online.
-
04-26-2011, 03:29 PM
Thread: Danfoss VLT Micro drive
by maustin- Replies
- 3
- Views
- 918
Danfoss VLT Micro drive
Does anyone have any experience setting one of these units up? Got one to use on a cooling tower fan. The programming manual is pretty vague and not very intuitive.
Any constructive input is... -
04-21-2011, 11:48 AM
Thread: What CFM vacuum pump
by maustin- Replies
- 12
- Views
- 1,189
My new JB eliminator, 5 cfm I believe, with a...
My new JB eliminator, 5 cfm I believe, with a 1/2" hose just pulled a 600 ton centrifugal from atmospheric to 750 microns in 24 hours. I changed the oil once before I went home for the night.
... -
03-11-2011, 02:44 PM
- Replies
- 6
- Views
- 807
Run the pump when the forecast calls for...
Run the pump when the forecast calls for temperatures that you expect to cause freezing in the attic.
We run about 30% +/- glycol solution in our chilled water loops, if I recall that is good down... -
03-10-2011, 02:34 PM
Thread: York compressor Z style
by maustin- Replies
- 3
- Views
- 613
Try http://www.cmpcorp.com
Try http://www.cmpcorp.com
-
01-18-2011, 03:20 PM
- Replies
- 32
- Views
- 1,359
Read the manuals that are available on this site,...
Read the manuals that are available on this site, there are tons of them! I may be considered a junkie, but I'll read a manual for the fun of it.
-
01-12-2011, 01:20 PM
Thread: Three wire pressure transducer
by maustin- Replies
- 11
- Views
- 1,436
I've seen that or a very similar message on the...
I've seen that or a very similar message on the one line marquee type display when the machine had air in it. Check your condenser approach and purge rate. Maybe York56 will chime in here.
-
01-12-2011, 01:15 PM
Thread: Pace air handlers
by maustin- Replies
- 3
- Views
- 1,661
Air Handler Services Inc. 16933 S. Hattan Rd....
Air Handler Services Inc.
16933 S. Hattan Rd.
Oregon City, OR 97045
503-631-7560
Don't remember the fellas name there, but he quoted some shafts and wheels for us a few years ago on a early... -
01-10-2011, 05:43 PM
Thread: Three wire pressure transducer
by maustin- Replies
- 11
- Views
- 1,436
Are you getting a message to the effect of "evap...
Are you getting a message to the effect of "evap pressure tranducer out of range" ?
-
12-21-2010, 11:09 AM
Thread: Electric boiler issues
by maustin- Replies
- 9
- Views
- 672
overcurrent
overcurrent
-
09-30-2010, 10:56 AM
Thread: problem w/ cornelius ice maker
by maustin- Replies
- 5
- Views
- 894
Is it an XWC 530? Is it showing harvest fail?
Is it an XWC 530?
Is it showing harvest fail? -
09-21-2010, 09:57 AM
Thread: Oh....thanks for your business.
by maustin- Replies
- 18
- Views
- 989
When I owned my shop my philosophy was "I can...
When I owned my shop my philosophy was "I can make nothing doing nothing"
:couch: -
07-14-2010, 02:13 PM
- Replies
- 4
- Views
- 650
Search this section, there are a ton of factory...
Search this section, there are a ton of factory manuals that members have provided. Download them and start reading.
-
04-06-2010, 12:48 PM
Thread: Need 7.5 ton 2 stage split unit
by maustin- Replies
- 18
- Views
- 1,899
We just put one in.
We just put one in.
-
04-06-2010, 10:49 AM
Thread: Need 7.5 ton 2 stage split unit
by maustin- Replies
- 18
- Views
- 1,899
ICP CAE090GHC, is the 208 volt, 3 phase model....
ICP CAE090GHC, is the 208 volt, 3 phase model. Dual copeland scrolls, GE fan motor. I've havent had any trouble with them. $2500 out the door at United Refrigeration. Its a single circuit though.
-
02-27-2009, 10:46 AM
Thread: 600 amp breaker???
by maustin- Replies
- 8
- Views
- 909
If the breaker serves just the 359 amp compressor...
If the breaker serves just the 359 amp compressor NEC table 430.52 says that the breaker can be sized at 250% RLA. If the breaker serves the machine with more than 1 359 amp compressor, it would be...
-
02-20-2009, 01:33 PM
Thread: Are you getting the incentive yet ?
by maustin- Replies
- 11
- Views
- 656
These are the times that make me glad that I gave...
These are the times that make me glad that I gave up being a field tech years ago and hired on with a state agency as an in house hvac tech at a large institution. I've read a lot bashing of the "in...
-
11-18-2008, 10:30 AM
- Replies
- 12
- Views
- 766
I just changed out an old 30GB055 and an ALR060...
I just changed out an old 30GB055 and an ALR060 with a new YCAL134. I don't know where you are located but I used vinyl jacketed styro foam insulation and applied embossed aluminum skin that came...
Results 1 to 25 of 129