Search: Search took 0.01 seconds.

  1. Replies
    6
    Views
    220

    has anyone verified the blower is on?

    has anyone verified the blower is on?
  2. Replies
    542
    Views
    67,275

    if it meant that much to you, why dont you call...

    if it meant that much to you, why dont you call at lunch time. Time zone excuse sounds lame.
  3. Replies
    9
    Views
    979

    I would of run a pump up and then back down but...

    I would of run a pump up and then back down but water will find its own level. Meaning the water leaving the unit is above 3 ft the water to the drain is only a inch or two above the floor it will...
  4. DWB898 get off the caps lock. That is considered...

    DWB898 get off the caps lock. That is considered YELLING.
    Second thing: break up your wording, this will make it easier for people to follow along.

    Insulting people is not a good thing.
    might...
  5. Also note the stuff out now is a higher content...

    Also note the stuff out now is a higher content of THC then we had in the 60's or 70's
  6. Replies
    7
    Views
    725

    when you overheat the copper or brass it will not...

    when you overheat the copper or brass it will not cavitate or pull in the liquid it will just drip off. stop cool down the pipe and use less heat or a rosebud for more surface area get in get out. if...
  7. Replies
    12
    Views
    902

    also make sure not to put the sensor in a direct...

    also make sure not to put the sensor in a direct leak like one off a tank of refrigerant to test. great way to kill the heater.
    Bruce
    p.s the heaters are not priced to bad. more than likely that...
  8. Replies
    17
    Views
    1,282

    the condensor fan out or dirty coil causing head...

    the condensor fan out or dirty coil causing head pressure to raise which raises suction pressure? clean everything the chech again. another check would be to pull the evap fan and see how it frost up...
  9. Replies
    8
    Views
    660

    What about 408a and 409 depending on the...

    What about 408a and 409 depending on the aplication? We use it. not cheap but works pretty good.
  10. might be the txv power head causing it to act...

    might be the txv power head causing it to act closed. start there
  11. Replies
    7
    Views
    821

    why not consider the digicool ak900 I have this...

    why not consider the digicool ak900 I have this and it is solid built. UEI also sells it, and it comes with the clamps already. Great unit. Just Saying..
    Bruce
  12. Thread: My accident...

    by N2fords
    Replies
    56
    Views
    10,090

    Lol

    Lol
  13. Replies
    5
    Views
    503

    nice the picture is really small hard to see but...

    nice the picture is really small hard to see but I can tell it pulled out nicely to access the condensor parts.
  14. Thread: My accident...

    by N2fords
    Replies
    56
    Views
    10,090

    running on empty and taking a picture of his hand...

    running on empty and taking a picture of his hand will driving 30 plus miles per hour. must be looking for another accident
  15. Replies
    43
    Views
    1,407

    i can say that if the water was not draining then...

    i can say that if the water was not draining then that is why you had high humidity. thats why they asked if the line was clear. now you should be ok. ps do not turn the cold control knob to 9 as it...
  16. Replies
    43
    Views
    1,407

    the hun calling people jerks when clearly you are...

    the hun calling people jerks when clearly you are in the wrong forum, is not our problem. we are professionals and these guys bend over backwards to help most people. The 20 you are reading is air...
  17. Replies
    35
    Views
    1,266

    Not only that but also which 2 legs control the...

    Not only that but also which 2 legs control the transformer.
  18. Replies
    2
    Views
    522

    always Replace like for Like when possible. Are...

    always Replace like for Like when possible. Are we talking robbing peter to give to paul? if so i makes no sense to me.
  19. Replies
    35
    Views
    1,266

    3 phase delta or why he did not say if its 208 or...

    3 phase delta or why he did not say if its 208 or 240 3 ph. might be the problem right there.
  20. Replies
    9
    Views
    649

    Just a thought, Is the Lp tank Low? whats your...

    Just a thought, Is the Lp tank Low? whats your pressure before the gas valve and after and will running does it drop off. maybe moister in the line?
    Bruce
  21. Replies
    37
    Views
    1,975

    is the distributor tubes after the TXV clogged?...

    is the distributor tubes after the TXV clogged? Just a thought?
  22. Replies
    53
    Views
    2,701

    is the door sealing up. I have seen bad gaskets...

    is the door sealing up. I have seen bad gaskets or door alignment issues cause this in a hot kitchen.
  23. Replies
    7
    Views
    555

    Like I said cool tool. I have all kinds of...

    Like I said cool tool. I have all kinds of expensive tool and might even add this to my pockets. Just making a point for new to the trades of money watchers how to use a small screw driver or the...
  24. Replies
    7
    Views
    555

    cool tool but my pocket screw driver will feel...

    cool tool but my pocket screw driver will feel the magnetic field if the coil is operating.
    Bruce
  25. Thread: Scotsman

    by N2fords
    Replies
    6
    Views
    563

    does it have the black box? I read somewhere the...

    does it have the black box? I read somewhere the new Eyes are only for the new box and doesnt play well with the black box after a month! hope this helps
  26. helioson do you work for Market Equipment or Doc/...

    helioson do you work for Market Equipment or Doc/ I lived many years there and recieved my degree in Spokane community back in 2000.
    Bruce
  27. Replies
    26
    Views
    2,751

    I have the 116 and the 16 as well good meters

    I have the 116 and the 16 as well good meters
  28. Replies
    26
    Views
    2,751

    Fluke true RMS I have 3 or four fluke RMS meters...

    Fluke true RMS I have 3 or four fluke RMS meters and love them all . 2 are clamp type. which is i think 324 its my carry around meter! hope this helps
  29. Replies
    23
    Views
    2,446

    I just use my Ak900 Digicool close off the 1/4...

    I just use my Ak900 Digicool close off the 1/4 turn to the suction side so I can set my input pressure from my nitrogen tank and then let it flow at 1.5 psig allow it to flow through the entire sytem...
  30. Replies
    21
    Views
    1,560

    That was back in the 90's can't remember the amps...

    That was back in the 90's can't remember the amps but temp was over 3000f
  31. Replies
    21
    Views
    1,560

    Carbon electrodes the size of my thighs 5 ft...

    Carbon electrodes the size of my thighs 5 ft long. 3 each of course
  32. Replies
    21
    Views
    1,560

    Worked as a furnace operator melting Cast Iron...

    Worked as a furnace operator melting Cast Iron and 4160 3 phase was our flavor or electricity. powerful stuff. Dangerous yes to the untrained. it was some fun times there in Washington State.
  33. Replies
    10
    Views
    848

    it also matters what type of education or job...

    it also matters what type of education or job experience you had prior to submitting for pro membership. I was I Jet Mechanic who went to Embry Riddle Areonautical Unv. Also an AAS Degree in HVAC/R...
  34. Replies
    10
    Views
    887

    Not trying to start anything but I have had great...

    Not trying to start anything but I have had great luck with Paragon digital and seen many Grasslins fail.Why not just carry the paragons and if power goes out time is always correct on the paragons
  35. Replies
    14
    Views
    2,855

    Do a Google search it is used to keep the...

    Do a Google search it is used to keep the Acetylene stable that's why you keep the bottle upright.
  36. Replies
    14
    Views
    2,855

    the bottle is straight up right? otherwise you...

    the bottle is straight up right? otherwise you could be pulling in acetone!
  37. Replies
    7
    Views
    1,590

    I wish they would of had the kindle when I first...

    I wish they would of had the kindle when I first started this bussiness for about 79 bones you can get one. it will be your bible with all the pdf's you can load for controllers equipment wiring...
  38. Replies
    69
    Views
    3,145

    Said that already many times

    Said that already many times
  39. Replies
    69
    Views
    3,145

    It doesn't..

    It doesn't..
  40. Replies
    69
    Views
    3,145

    If both sides where sucking where is the...

    If both sides where sucking where is the refrigerant
  41. Replies
    69
    Views
    3,145

    Its would still go right past the broke discharge...

    Its would still go right past the broke discharge reed into the high side even if CSP tube was clogged
  42. Replies
    69
    Views
    3,145

    When the discharge valve is bad it won't build up...

    When the discharge valve is bad it won't build up compression but the gas in the system will still be at static pressure for temperature
  43. Replies
    69
    Views
    3,145

    If there is refrigerant in the system it would...

    If there is refrigerant in the system it would read on the high side period. Now if he's not seeing it then it could he is not depressing the Schrader or the ref is gone. If he shuts off the...
  44. Replies
    69
    Views
    3,145

    I am going to let you ponder that thought for a...

    I am going to let you ponder that thought for a while.
  45. Replies
    69
    Views
    3,145

    The refrigerant has to go and be somewhere.

    The refrigerant has to go and be somewhere.
  46. Replies
    69
    Views
    3,145

    No way high side is zero

    No way high side is zero
  47. Replies
    69
    Views
    3,145

    Zero vacuum with a bad pump really

    Zero vacuum with a bad pump really
  48. Replies
    69
    Views
    3,145

    I too enjoyed the video.

    I too enjoyed the video.
  49. Replies
    69
    Views
    3,145

    maybe he has his high side hose on backwards no...

    maybe he has his high side hose on backwards no depressor to push schrader open.
  50. Replies
    69
    Views
    3,145

    Chances are the captube is plugged at the filter...

    Chances are the captube is plugged at the filter drier.
    Did you change the filter drier?
    I cut the cap tube back when i replace the filter drier and always, use nitrogen to enter on the low side to...
Results 1 to 50 of 222