Search: Search took 0.00 seconds.

  1. Replies
    2
    Views
    664

    PTM6.EMK Modules Apogee System

    I am looking to find a dealer or somehow a stock for PTM6.EMK modules. These modules are parts of Apogee system and seems to be discontinued.
    Any information will be helpful.
  2. Replies
    161
    Views
    32,210

    Στέλιο γεια.. Αν χρειαστείς κάτι επιπλέον για...

    Στέλιο γεια..
    Αν χρειαστείς κάτι επιπλέον για την διασύνδεση με την daikin στείλε μου email.
  3. Replies
    161
    Views
    32,210

    The same exist for you Nickh,

    The same exist for you Nickh,
  4. Replies
    161
    Views
    32,210

    Volgarixon just send you a copy of the specific...

    Volgarixon just send you a copy of the specific software, hope this help
  5. Replies
    4
    Views
    1,502

    Hello Kev I know that Siemens has a gateway...

    Hello Kev

    I know that Siemens has a gateway (PXC00-U) which supports integration between the legacy systems (like AS1000 or pronto) to BACnet over Lon or IP. I don't know if the same exist for...
  6. Replies
    161
    Views
    32,210

    Hi steve You will receive an email from...

    Hi steve

    You will receive an email from sendspace. I attached all the documents and programs that i had for DAIKIN D-BACS.
    Hope that these will help
  7. Replies
    161
    Views
    32,210

    Hi Steve If you did not manage to find...

    Hi Steve

    If you did not manage to find SetupBACnet send me an email to attach you the software.
  8. Replies
    7
    Views
    2,310

    I have already enabled this function. It will...

    I have already enabled this function.
    It will be much helpful if this setup tool had more options for event notification like editing the recipient list.
  9. Replies
    7
    Views
    2,310

    Thanks picnik i just add my email

    Thanks picnik i just add my email
  10. Replies
    7
    Views
    2,310

    Thank you very much for your help. Today i tried...

    Thank you very much for your help.
    Today i tried to modify the recipient list property but with no lack.
    I was getting a general error message.
    The string that i was tried to write was:
    ...
  11. Replies
    7
    Views
    2,310

    Daikin VRV BACnet Gateway

    Does anyone knows how to edit Event notification recipient registration in a DMS502B51 DBacs Daikin Gateway.
    The SCADA software is Desigo Insight and communicates direct with this device.
    The...
  12. Replies
    19
    Views
    1,951

    waldoverkill thank you for your asnwer. I have...

    waldoverkill thank you for your asnwer.
    I have the following questions for the Insight Bacnet Server.
    Do this version support P2 protocol from V1.xx firmware MBCs?
    Is it possible to upgrade the...
  13. Replies
    19
    Views
    1,951

    Thank you for the link information. I will try a...

    Thank you for the link information. I will try a contact with them.

    Many years ago here in Greece Landis&Gyr installed some legacy S600 systems and for the moment are still working fine.
    My...
  14. Replies
    19
    Views
    1,951

    The problem is that Greece does not have dealers...

    The problem is that Greece does not have dealers and of course technical support for Tridium and Aletron systems, so no matter how many the benefits of those systems are, technical and material...
  15. Replies
    19
    Views
    1,951

    MatrixTransform this world is not perfect. We...

    MatrixTransform this world is not perfect. We just trying to be flexible....
  16. Replies
    19
    Views
    1,951

    Thanks for the suggestion MatrixTransform. This...

    Thanks for the suggestion MatrixTransform.
    This is quite difficult for 35 MBCs in a building.
  17. Replies
    19
    Views
    1,951

    I think that this solution is only for TEC...

    I think that this solution is only for TEC devices (not a P2 protocol).
  18. Replies
    19
    Views
    1,951

    Thank you for your answers. I know that Siemens...

    Thank you for your answers.
    I know that Siemens USA has a solution but they do not support european partners.
    The problem is that we have several installations of S600 system in Greece, where there...
  19. Replies
    19
    Views
    1,951

    S600 P2 protocol to BACnet

    Hello everyone

    Is there any solution, like a hardware gateway, for mapping P2 protocol datapoints to BACnet objects.
    The concept is to integrate an old S600 Landis&Gyr System in a BACnet system....