Search:

Type: Posts; User: pelican

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    43
    Views
    3,162

    unit way overcharged lol let some gas out so it...

    unit way overcharged lol let some gas out so it can start
  2. Replies
    8
    Views
    699

    anyone have a clear understanding of the program...

    anyone have a clear understanding of the program pertaining to a/c and heat pumps ?
  3. Replies
    8
    Views
    699

    1500.oo rebates federal

    If the customer does not have a tax liability are they still eligable for the rebate for high efficient equiptment?
  4. Replies
    23
    Views
    1,820

    just what we need another customer up our...

    just what we need another customer up our assthinking they know something.close this thread or move it to pro
    please ?
    Residential HVAC Questions and discussions pertaining to HVAC for the home. No...
  5. Replies
    19
    Views
    1,957

    They pay you in sunshine!Not much more.

    They pay you in sunshine!Not much more.
  6. Replies
    23
    Views
    1,820

    go ahead blow the guy up.move to pro please

    go ahead blow the guy up.move to pro please
  7. Replies
    41
    Views
    6,097

    anybody?

    anybody?
  8. Replies
    41
    Views
    6,097

    Sounds like the condenser motor should be...

    Sounds like the condenser motor should be replaced as well ie. freeze ups in winter and high head in summer.
  9. Replies
    23
    Views
    1,820

    burned off eye brows eye lashed and bald spot is...

    burned off eye brows eye lashed and bald spot is no fun.
  10. Replies
    41
    Views
    3,792

    and what did he say about wire size and adding a...

    and what did he say about wire size and adding a heater ?oh thats right you dont need a permit heck put 15kw heat in then.
  11. Didja get shocked?lol OR CALL YOUR CONTRACTOR...

    Didja get shocked?lol

    OR CALL YOUR CONTRACTOR ANS SIT BACK AND RELAX
    :couch:
  12. Replies
    41
    Views
    3,792

    ok if you went from a water to air to a air to...

    ok if you went from a water to air to a air to air heat pump it is considered a NEW installation that would call for a PERMIT and INSPECTION.Good luck my vc2 cents are spent!
    p.s. alum wire not used...
  13. Replies
    41
    Views
    3,792

    on another not you refered to the cold blast when...

    on another not you refered to the cold blast when in defrost .make sure it is set to 90 minutes .If frosting is not a big issue in your area you may be able to bypass it by removing
    defrost sensor...
  14. Replies
    41
    Views
    3,792

    minimum circuit amp will determine fuse size in...

    minimum circuit amp will determine fuse size in some states others want proper size breaker.What about the permit for the work and the city inspection?didc they tell you you dont need 1?its...
  15. Replies
    41
    Views
    3,792

    Jim yo need the smaller breaker per code and no...

    Jim yo need the smaller breaker per code and no the wire is too small to add heat strip.
  16. Replies
    41
    Views
    3,792

    ADD 30 TO THEN NUMBER TO GET TOTAL AMPS WITH...

    ADD 30 TO THEN NUMBER TO GET TOTAL AMPS WITH HEATER FOR THAT UNIT
    YOU WILL FIND IT IS TOO SMALL A BREAKER
    5 KW ABOUT 22 AMPS AT 240V AND FUSED AT 30 AMPS ALONE.
    #8 ALUM WIRE 35 AMPS#6 WIRE ALUM...
  17. Replies
    41
    Views
    3,792

    YOU GAVE US A MINIMUM CIRCUIT AMPS AS 28WHAT IS...

    YOU GAVE US A MINIMUM CIRCUIT AMPS AS 28WHAT IS THE MAX FUSE OR BREAKER LISTED ON THE 3 1/2 TON HEAT PUMP?"New Trane WCH042C100A HP just in stalled by local company. Trane specs call for min. 28A....
  18. Replies
    23
    Views
    1,313

    You can learn a great deal at this site .It is a...

    You can learn a great deal at this site .It is a great resource!Sorry fore the sarcastic remark but i know the rules and you had 1 post.Registration is easy{if you are in the field}so please feel...
  19. Replies
    23
    Views
    1,313

    are you the home owner? furnace?

    are you the home owner?
    furnace?
  20. Replies
    23
    Views
    1,313

    Arcoair new gas furnice inside. Everybody so far...

    Arcoair new gas furnice inside. Everybody so far says look at your low voltage side. Furnace works fine. buy more fuses duh?
  21. Replies
    6
    Views
    785

    how cold is the condenser water?does it have a...

    how cold is the condenser water?does it have a sea cock that you can throttle down the water to see if you can get your head up?What happens when you add a little more gas?
    How much did you put...
  22. Replies
    35
    Views
    2,613

    small reach ins i use a duct iron.

    small reach ins i use a duct iron.
  23. Replies
    7
    Views
    805

    And just how much oil are you adding to these...

    And just how much oil are you adding to these little compressors???????????
  24. Replies
    5
    Views
    548

    PLUG IT IN IN A DIFFERENT RECEPTCLE SEE IF IT...

    PLUG IT IN IN A DIFFERENT RECEPTCLE SEE IF IT STILL SHOCKS YOU.ELIMINATE THE REFER FROM THE REAL PROBLEM.
  25. Thread: traulsen help

    by pelican
    Replies
    12
    Views
    1,950

    It is a RS485 port available as a means of...

    It is a RS485 port available as a means of retrieving information from the stored data .72 hours is stored such as alarms,door open cycles , defrost cycles and records cabinet air temp every 6...
  26. Replies
    26
    Views
    2,335

    have you checked the vent pipe chart for proper...

    have you checked the vent pipe chart for proper sizing?something doesnt look right there?Sinsle wall pipe?where is the b-vent?
  27. Replies
    6
    Views
    874

    Hi Berg ,I work for a local co here in clearwater...

    Hi Berg ,I work for a local co here in clearwater doing resteraunt refrigeration ,alot of McD's burger kings as well as mall work.
  28. Replies
    6
    Views
    874

    where you at berg?

    where you at berg?
  29. Replies
    6
    Views
    874

    ITS NOT ENTRY LEVEL ITS THE PAY SCALE HERE IN...

    ITS NOT ENTRY LEVEL ITS THE PAY SCALE HERE IN FLORIDA!ITS A VERY LOW PAY AREA.SUNSHINE IS PART OF YOUR BENEFIT PKG.
  30. Replies
    11
    Views
    594

    12-21 -2012 the end is near google it.

    12-21 -2012 the end is near google it.
  31. Thread: Part time job

    by pelican
    Replies
    6
    Views
    914

    A tough way to make a living any more.If you fall...

    A tough way to make a living any more.If you fall behind on child support here in Florida they take your drivers license .how f-ed up is that?Ineed to do something soon,I recently switched to...
  32. Thread: Part time job

    by pelican
    Replies
    6
    Views
    914

    Part time job

    Anyone working a part time job while things are slow in the hvac regular job?How do you handle the one week on call rotation?Can you tell your part time employer "hey i gotta go catch a service call...
  33. Replies
    16
    Views
    1,368

    'My career has been very humbling and rewarding...

    'My career has been very humbling and rewarding at times to say the least and I am glad to find a community of people that I can bounce things off of.
    Remember us "little guy's when you get great...
  34. Thread: Helmer Hlf125

    by pelican
    Replies
    10
    Views
    1,361

    sounds like its working right as it is.coil clear...

    sounds like its working right as it is.coil clear after 5 or 10 minutes .
  35. Thread: Helmer Hlf125

    by pelican
    Replies
    10
    Views
    1,361

    to answer your question yes.a 3wire clikson...

    to answer your question yes.a 3wire clikson switch attached to the evap coil controls defrost termination by temp and energizes a coil in the timer to terminate or stop defrost .usually the x...
  36. Replies
    33
    Views
    2,941

    carful boxes converted to txv subject to...

    carful boxes converted to txv subject to spontanious combustion and melt down!:eek:
  37. Replies
    15
    Views
    3,913

    o

    o
  38. Replies
    15
    Views
    3,913

    is there a fire damper closed in the duct work?...

    is there a fire damper closed in the duct work?
    Is the condensate comming fron the inside or the outside of the duct?you said a 5 story building,does it rise 5 stories to exhaust?Is FAN TURNING IN...
  39. Replies
    16
    Views
    2,022

    cash it before 2 tomorrow .dont deposit it,:)

    cash it before 2 tomorrow .dont deposit it,:)
  40. Replies
    5
    Views
    1,155

    please feel free to donate said info to our...

    please feel free to donate said info to our education forum as well.
  41. Replies
    11
    Views
    830

    use to use them alot in the warhouse cold storage...

    use to use them alot in the warhouse cold storage 20 years ago, .havent seen thje first 1 here with the new company.could be my niche part.call today major chain rest. dropped leg blew fuse to both...
  42. Replies
    11
    Views
    830

    use to use them alot in the warhouse cold storage...

    use to use them alot in the warhouse cold storage 20 years ago, .havent seen thje first 1 here with the new company.could be my niche part.call today major chain rest. dropped leg blew fuse to both...
  43. Replies
    11
    Views
    830

    3 PHASE MONITORS

    Are you guys using phase monitors on any of your units or package refrig systems?
  44. Replies
    16
    Views
    2,022

    unless the amount you charged caused the heart...

    unless the amount you charged caused the heart attack .:D
  45. Replies
    16
    Views
    2,022

    cash it now dead men write no checks you did the...

    cash it now dead men write no checks you did the work get paid 4 it.
  46. Replies
    9
    Views
    1,934

    sometimes you have to settle with what ya got...

    sometimes you have to settle with what ya got wish we could make em all perefect
  47. Replies
    9
    Views
    1,934

    Is there a head master on the condensing...

    Is there a head master on the condensing unit?with the temperature change it could be bypassing the coil and a little low on charge,compressor runs warmer too i have found.
  48. Thread: copeland comp

    by pelican
    Replies
    18
    Views
    1,598

    could be a stuck potential realay on the start...

    could be a stuck potential realay on the start capacitor.you opened the discharge valve right?check your amp draw,sounds like a miswire
  49. Thread: copeland comp

    by pelican
    Replies
    18
    Views
    1,598

    what is your experiance installing these units ?

    what is your experiance installing these units ?
  50. Thread: copeland comp

    by pelican
    Replies
    18
    Views
    1,598

    how is it wired?did you install new start...

    how is it wired?did you install new start components? will it do it when you put in the third compressor?>its not the not the voltage being high.
Results 1 to 50 of 138
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event