    Carrier 5 ton systems that qualify: ARI#...

    Carrier 5 ton systems that qualify:

    ARI# 3344656
    25HCB561A30
    FX4CN(B,F)060

    ARI# 3344695
    25HCB561A30
    FV4BNB006
  2. Replies
    16
    Views
    1,140

    You can not compare an option on a car to an...

    You can not compare an option on a car to an option on a HVAC system because you are not asking for the same information.

    A option on a car is an additional item or system such as a brake package...
  3. If you were replacing the units then I wouldn't...

    If you were replacing the units then I wouldn't see a problem as long as the installation company followed the manufactures long line application guide which would call for additional accessories and...
  4. R410A Phase down????

    R410A phase down? :confused:
  5. Replies
    16
    Views
    1,140

    a) Will be in tonnage on the A/C side of things. ...

    a) Will be in tonnage on the A/C side of things. You can purchase the software yourself if you really wanted to but its not cheap software.

    b) Would you ask the Toyota dealer to itemize each item...
  6. Is this a National Account for Carrier?

    Is this a National Account for Carrier?
  7. Replies
    8
    Views
    648

    Congrats!!!

    Congrats!!!
  8. Replies
    13
    Views
    1,818

    Wow... never came across one that bad!

    Wow... never came across one that bad!
  9. Replies
    0
    Views
    315

    Penske to buy Saturn

    DETROIT A person briefed on the deal says General Motors Corp. will sell its Saturn brand to former race car driver and dealership chain owner Roger Penske.

    GM has scheduled a 9 a.m. EDT...
  10. As Ryan said... you have two options for the...

    As Ryan said... you have two options for the Federal Tax Credits.

    Option 1) Use a A/C System that has an ARI number with 16 SEER 13 EER or a HP System with 15 SEER 12.5 EER 8.5 HSPF (FAU does not...
  11. Replies
    35
    Views
    1,822

    3/4" is required in So Cal... some cities want...

    3/4" is required in So Cal... some cities want more
  12. How are you getting a HSPF number when this isn't...

    How are you getting a HSPF number when this isn't a heat pump system? Since this isnt a HP you need to meet the 16 SEER 13 EER requirements. Also, the 24APA5 is not a two stage condensing unit.
  13. See if your contractor has access to the ADP "C"...

    See if your contractor has access to the ADP "C" coils. If so you can use a standard type FAU with the following ARI combination #3325427:

    24ANA148A31
    C60A***C336
    58CV(A,X)090-16

    This will...
  14. Replies
    6
    Views
    834

    Carrier is still producing the Commercial Splits...

    Carrier is still producing the Commercial Splits in R22, the R410 versions have not been released yet.
  15. Either 2,200 or 2,000 CFM. The model number with...

    Either 2,200 or 2,000 CFM. The model number with the 20 is incorrect. The current model numbers are 58CVA155---1--22 or 58CVA135---1--22. The only 2,000 CFM is the 58CVA110---1--20.
  16. I have had the same problem with Trane, York, and...

    I have had the same problem with Trane, York, and Carrier. National accounts for equipment drive the profit margins for the contractors way down. :mad:
  17. On commercial projects?

    On commercial projects?
  18. Why not? He is bringing world peace through his...

    Why not? He is bringing world peace through his glorious works!
  19. I heard he hung himself.... very sad.

    I heard he hung himself.... very sad.
  20. Replies
    39
    Views
    5,520

    I'm already a fatty.... but none of that looks...

    I'm already a fatty.... but none of that looks appealing to me. :(
  21. Replies
    5
    Views
    1,494

    That right there is funny no matter who you are

    That right there is funny no matter who you are
  22. Are you are talking about the new "C" evap coils?...

    Are you are talking about the new "C" evap coils? They are good... built better than previous ADP coils. Just take the sizes in consideration when installing them. The upflow coils are 31.5" tall.
  23. Replies
    67
    Views
    7,340

    I went on a estimate a few years ago with a...

    I went on a estimate a few years ago with a backyard that actually had more can and bottles than this one. I was walking on top of bags of trash to get to the unit. When I got to the unit I decided...
  24. Thread: NASCAR

    by StarStripes00
    Replies
    15
    Views
    901

    This past weekend my wife and I went to an...

    This past weekend my wife and I went to an outdoor mall and sat outside enjoying people watching. We were sitting there for maybe 30 minutes or so; across from us was the valet which had a Yellow...
  25. Replies
    12
    Views
    542

    We suck! I'm still trying to figure out why I...

    We suck! I'm still trying to figure out why I haven't left this state yet... :mad:
  26. California has been doing this for years......

    California has been doing this for years... welcome to the Golden State!
  27. Replies
    16
    Views
    1,040

    So if I'm reading this correctly, the Amana...

    So if I'm reading this correctly, the Amana dealer is going to replace both units with (1) 5 ton? What is he doing with the ductwork?

    Have any of them completed a Manual J to see what the true...
  28. Replies
    10
    Views
    2,471

    The pans on fan coils don't usually have a...

    The pans on fan coils don't usually have a problem.... so why would you stock a part you don't ever sell?
  29. The factory portion basically covers the...

    The factory portion basically covers the equipment itself and not the installation costs. Make sure that the FAD completes all the proper paperwork required by Carrier.
  30. Replies
    20
    Views
    1,466

    Very simple solution... ask him for the AHRI...

    Very simple solution... ask him for the AHRI certificate for the combination that he is offering.

    You can even look it up yourself.
    ...
  31. Replies
    7
    Views
    1,085

    You will also see this in some of the AHRI...

    You will also see this in some of the AHRI numbers to increase the efficiencies to meet the Tax Credit standards.
  32. Replies
    3
    Views
    2,752

    Thanks for the help... found that it's a FIOP...

    Thanks for the help... found that it's a FIOP option for a high static motor
  33. Replies
    3
    Views
    2,752

    Carrier Model Number?

    I have most of the information on this model number... but what is included in the option code?

    48TJD006---601GA

    48TJ Gas/Electric
    D Low Heat
    006 5 tons
    - No Controls
    - ...
  34. Replies
    3
    Views
    1,676

    If wanting a HP you can go with the Carrier 50VT....

    If wanting a HP you can go with the Carrier 50VT. This a Performance series level HP that qualifies for the Federal Tax Credit.
  35. This depends on what you are wanting to get out...

    This depends on what you are wanting to get out of the new condensing unit. If you are looking for a higher efficiency system that qualifies for the Federal Tax Credit and be eligible for Carrier...