  1. Thread: A/C renew

    by burto
    Replies
    17
    Views
    953

    I went to johnstones to get some and a 4 oz....

    I went to johnstones to get some and a 4 oz. bottle is $106 . you got to kidding me
  2. Replies
    9
    Views
    363

    installing humidifires on second floors

    the company i work for has gotten into residential to keep business going and is doing a great job. one thing
    that scares me is installing humidifires on second floors. some of these houses look...
  3. remember when I was cutting my teeth we did a lot...

    remember when I was cutting my teeth we did a lot of bar rooms and restaurants and would carry a jug of refrigerant and just blast out condensing units. using a map book was a drag especially trying...
  4. Replies
    4
    Views
    230

    its for a hot water loop in a wicked dated...

    its for a hot water loop in a wicked dated apartment building. there's a old carrier chiller for the chilled water in summer
  5. Replies
    28
    Views
    1,305

    show us some pics

    show us some pics
  6. Replies
    4
    Views
    230

    economite conversion burner sighting

    was cutting thru mechanical room and saw a nice surprise. was amazed how well they where still running.
  7. Replies
    2
    Views
    283

    Ancient HB Smith #34 Boiler

    Have a boiler that heats up a bunch of suspended unit heaters. I wish I took a pic of the steam traps. I think their bucket traps. Are theses the only thing that returns the condensate to the boiler...
  8. Thread: sweet bee hive

    by burto
    Replies
    9
    Views
    1,621

    sweet bee hive

    Has anyone come across these lately. Always a nice surprise after taking off a panel.
  9. Replies
    6
    Views
    437

    hadn't seen them but will definitely try thanks....

    hadn't seen them but will definitely try thanks. like the idea of a different manufacturer.
  10. Replies
    6
    Views
    437

    noisey ductless split pumps

    513491513501513511513521

    had to install a bunch of these pumps and have had nothing but trouble.my biggest...
  11. Replies
    8
    Views
    490

    Put one in recently on a motion picture movie...

    Put one in recently on a motion picture movie trailer {115 volt model} and was very impressed. Indoor section was very light and the condencer seemed well thought out. I haven't had to call tech...
  12. Replies
    14
    Views
    792

    I've had trouble with those CLO's. If all else...

    I've had trouble with those CLO's. If all else fails if you jump out the CLO it still uses the safties but wont lock out.
  13. Replies
    5
    Views
    432

    good idea I will look them up, a second opinion...

    good idea I will look them up, a second opinion would be great. wish I could have gotten that bypass going.
  14. Replies
    3
    Views
    359

    the times there a changing vfd's

    trying to stay current in this field is like a part time job. been hanging in there my whole career but knew these vfd's would get me eventually. took a day class from Honeywell but that's not...
  15. Replies
    5
    Views
    432

    its about 15 yrs old and we just inherited it....

    its about 15 yrs old and we just inherited it. tried powering on and off but nothing. not much you can do when it goes blank. the control side of vfd"s has always giving me trouble .the whole speed...
  16. Replies
    5
    Views
    432

    vfd with blank display on voyager

    hi guys, I have a trane m-TED600AEBE s-C99H14449M rtu. vfd has a blank display and the fault light is on. it has a bypass but cant even get that to come on. the vfd is a telemecanique m-atv66d16m2...
  17. Replies
    14
    Views
    955

    475251475261 What a difference with the new...

    475251475261

    What a difference with the new burner plate.
  18. Replies
    14
    Views
    955

    Ignitor and inducer are good.Will check orifice...

    Ignitor and inducer are good.Will check orifice tomorrow. Bringing out new burner plate.Never changed one before,hope that's it.
  19. Replies
    14
    Views
    955

    trane ych120 backfiring badly

    Hi Guys, Worked on a M- YCH120B3HODB S- J4B102135D RTU that when it starts it almost explodes.Once it gets going everything checks out fine. pressure is -.20 . The burner plate with...
  20. Replies
    0
    Views
    221

    old honeywell floating t-stat question

    Hi Guys,

    I have some old fan powered boxes with electric reheat and some vav`s with straight cooling. They were controlled with honeywells T641A1003 and T874C1018 floating...
  21. Replies
    1
    Views
    319

    Repairing a Testo 550

    Hi guys, I have a Testo 550 that just started leaking internally on the high side.Has anyone ever ran into this and has anyone ever tried opening their 550 up?
  22. checking charge on aircooled heat pumps in winter

    Hi guys, I can remember checking the refrigerant on air cooled split heat pumps in winter with the factory charge chart
    they used to print on the inside of the panels. Besides weighing in the...
  23. Replies
    19
    Views
    1,434

    Don't know why but when a condencer fan motor...

    Don't know why but when a condencer fan motor goes on a aaon your better off getting repl. directly from aaon. Had a summer when I tried everything then someone from talk straightened me out,almost a...
  24. Replies
    0
    Views
    440

    BAC COOLING TOWER

    Hey Guys,
    Have a BAC Cooling Tower M#VTO-102-MMXR S#U013301602 Center bearing is making some pretty good noise.My question is do i have to rebuild entire fan section or can i just do center...
  25. Replies
    8
    Views
    1,613

    Got it,If I put in 300psi and return in a day or...

    Got it,If I put in 300psi and return in a day or two and temps are ten degrees of each other,what do you think 5psi give or take?
  26. Replies
    8
    Views
    1,613

    Leak testing with nitrogen

    I always thought nitrogen stayed the same pressure in a system even if ambient temps change from one day to another.Do you guys see this to be true?
  27. Thread: blown 5 amp fuse

    by burto
    Replies
    12
    Views
    2,460

    Bet its the economizer.If the factory molex style...

    Bet its the economizer.If the factory molex style plug is still there you could bypass it for now.
  28. Replies
    8
    Views
    729

    Usually when I see a bypass from the supply to...

    Usually when I see a bypass from the supply to help control static it just dumps up in the ceiling,not connected to return,doesnt seem very efficient though.
  29. Replies
    11
    Views
    1,733

    ICM makes a nice Leed/Lag control thats easy to...

    ICM makes a nice Leed/Lag control thats easy to install,havnt had any trouble yet.
  30. Replies
    6
    Views
    1,005

    I used to like using the old Ranco pres. controls...

    I used to like using the old Ranco pres. controls to control pressures but dont see manafacturers recommending them anymore.
  31. Replies
    6
    Views
    1,005

    motor master install

    Hey guys, Have some basic A C condencing units and where installing motor-masters to control head preasure. Was wondering who leaves the factory sleeve bearing motors in and who puts in ball bearings...
  32. Replies
    14
    Views
    2,399

    that makes alittle sence.was working in a school...

    that makes alittle sence.was working in a school and the control guy said on his end (building automaition)they dont ground the common,something to do with interference.
  33. Replies
    14
    Views
    2,399

    floating ground ?

    hey guys, been a hvac tech for awhile but never heard of this before.if i come across a 24 volt transformer in say a rtu one side of secondary is grounded,in the control world sometimes you dont have...
  34. Thread: trane tam7 ahu

    by burto
    Replies
    1
    Views
    691

    trane tam7 ahu

    model-tam7a0c42h31sba serial-12212n8tav

    was wondering if this unit comes with any info on the computer board.
    tried starting one late friday and noticed board has lots of l.e.ds incuding police...
  35. Replies
    2
    Views
    667

    having all that stuff in the attic would be kind...

    having all that stuff in the attic would be kind of noisey,any chance of
    zoning the basement unit?
  36. Replies
    75
    Views
    9,095

    verbally should be fine,leaving a notice is...

    verbally should be fine,leaving a notice is good,dont burn any bridges
    its a small a/c world out there.
  37. Replies
    9
    Views
    1,867

    definely still out there ,ran into a m# 800 n 33...

    definely still out there ,ran into a m# 800 n 33 today.
    800k output, and purring like a kitten.
  38. Replies
    12
    Views
    1,045

    jinxed myself, came back in tonite. will try all...

    jinxed myself, came back in tonite.
    will try all these suggestions tomorrow.:gah:
  39. Replies
    12
    Views
    1,045

    ended up putting one of the large white-rogers...

    ended up putting one of the large white-rogers universal glow coils in
    and so far so good.
  40. Replies
    12
    Views
    1,045

    goodman 90+ intermit. locking out

    have a 6yr. old goodman 90+ locking out [1 flash ]
    m# gms90904cxs s#0409798428 cleaned sensor and
    replaced glow coil. the 1 flash on the panel is kind of vague,
    anyone come across this?
  41. Thread: Tool Storage

    by burto
    Replies
    40
    Views
    6,469

    ive been carrying tool boxes for years and my...

    ive been carrying tool boxes for years and my right shoulder was junk because of it.
    tried a cheap bag with a shoulder strap and im a new man, wish i thought of it sooner.
    alot safer climbing...
  42. Replies
    23
    Views
    2,386

    if you pull the comb. blower assembly out you can...

    if you pull the comb. blower assembly out you can
    see the screen,right before heat exchanger.
  43. Replies
    11
    Views
    1,324

    found out why this american standard kept locking...

    found out why this american standard kept locking out.
    they had a bulletin with certain ignition modules that
    were doing this and recommended on the molex plug
    terminal five is left blank to...
  44. Replies
    32
    Views
    3,700

    if its a heat pump its probably got a accumulator...

    if its a heat pump its probably got a accumulator right before
    compressor thought,I wonder if theres too much oil in system.
  45. Replies
    48
    Views
    8,486

    couple guys from work have drawer type chests and...

    couple guys from work have drawer type chests and like them,
    I like job boxes, they hold the big stuff and the bad guys cant
    get your stuff as easy.
  46. Thread: Sewer smell

    by burto
    Replies
    11
    Views
    1,745

    had similar problem at fancy restraunt like...

    had similar problem at fancy restraunt like you,soon as you get out
    of your vehicle you start smelling it .they had a septic issue,even
    after being pumped out it stunk.
  47. Replies
    11
    Views
    1,324

    the REP for AMER. STAND. says even if a limit...

    the REP for AMER. STAND. says even if a limit trips the main board
    can blink twice . wish it didnt the module has its own failure codes
  48. Replies
    11
    Views
    1,324

    it does but the ignition modules not telling me...

    it does but the ignition modules not telling me whats it
    going off on it just tells the main board and it blinks twice,ign.failure
  49. Replies
    11
    Views
    1,324

    gas pres. was -.24

    gas pres. was -.24
  50. Replies
    11
    Views
    1,324

    RTU ignition failure

    have a american standard RTU that keeps locking out on ignition
    failure.the main board shows the problem not the ignition module
    itself.just replaced glow coil and inducer assembly.blocked off two ...