  1. Replies
    4
    Views
    580

    Now that I think about it. I think it was a 90...

    Now that I think about it. I think it was a 90 bar that blew. Wouldn't ant to be around the 120.
  2. Replies
    4
    Views
    580

    It goes without saying but check the rating on...

    It goes without saying but check the rating on whatever components you are using. Allot of the Transcritical components max out at 120-140 bar working pressure. I guess theoretically you could test...
  3. Replies
    13
    Views
    2,052

    You might have one at the shop

    You might have one at the shop
  4. Thread: rack issues

    by cousteau
    Replies
    45
    Views
    2,553

    Be careful lowering these set points too much. ...

    Be careful lowering these set points too much. Defrost and liquid flow are your primary concerns. Remember your mainly trying to keep this system limping along under less than ideal conditions. You...
  5. Thread: rack issues

    by cousteau
    Replies
    45
    Views
    2,553

    if you think you have too much condenser now that...

    if you think you have too much condenser now that you have reduced load you could try change rotation on first fan (backwards spin will move less air) and/or apply cardboard...that said i think there...
  6. Replies
    7
    Views
    2,071

    Hydronics is Hydronics. (More or Less) Since...

    Hydronics is Hydronics. (More or Less)
    Since these systems seem to be taking off in our industry I am going to put a small workshop together for supermarket techs that explains the fundamentals of...
  7. Replies
    12
    Views
    769

    Call a broker. Personally I would ship it. If...

    Call a broker.
    Personally I would ship it.
    If you want to take it across yourself make sure all your paperwork is in order before you go.
    If you are flagged at the border it makes it harder to...
  8. Replies
    16
    Views
    1,289

    I have had some bad experience with Russell...

    I have had some bad experience with Russell condensing units and high head problems.

    Lots of undersized condenser motors. They never trip the internal when you are there.:mad:

    I had one...
  9. Replies
    473
    Views
    20,628

    OK. I was staying out of this since it seems to...

    OK. I was staying out of this since it seems to have been beaten to death. But for anyone that’s still reading here is my 2cents.

    People are generally more comfortable surrounding themselves with...
  10. Replies
    473
    Views
    20,628

    So... 18 pages in and no ones showing their work?...

    So... 18 pages in and no ones showing their work?
    Possibly a new thread;)
  11. Replies
    101
    Views
    7,091

    My 2 cents for what its worth as an employer that...

    My 2 cents for what its worth as an employer that has a fairly large tattoo although it's covered with a short sleeve shirt.

    Keep yours covered for the interview. If your asked be honest and show...
  12. Replies
    23
    Views
    1,775

    I'm not sure if you can buy them. I have a few...

    I'm not sure if you can buy them. I have a few that have just always been around and I have made a few.
  13. Replies
    23
    Views
    1,775

    Funny. I have been off the tools over 10 years...

    Funny. I have been off the tools over 10 years and I still do this. Even when I am grocery shopping. Old habits die hard! :)

    Another vote for the Jr here. With the Scoop.
  14. Replies
    5
    Views
    623

    I use mostly Allen Bradley but there are lots of...

    I use mostly Allen Bradley but there are lots of others that should work fine
    Good luck!
  15. Replies
    5
    Views
    623

    I had a customer that we did this for in their...

    I had a customer that we did this for in their fish coolers. We had trouble as the box temp was too close to the ice temp and it was finicky to set up.
    We replaced the stats with photo eyes and had...
  16. Replies
    10
    Views
    1,057

    I cant seem to get the document to load. Here are...

    I cant seem to get the document to load. Here are the highlits on this topic.
    Come by the office and I will print you the rest.

    6. Pipe the water side using unions, since water cooled condensers ...
  17. Replies
    10
    Views
    1,057

    Oilburner, This is one of those topics that...

    Oilburner,

    This is one of those topics that seems to trigger lots of debate.

    Here is some reading for you from the manufacturer of the condenser.

    I this case I would say go with what they...
  18. Replies
    39
    Views
    8,330

    You have mail.

    You have mail.
  19. Replies
    39
    Views
    8,330

    If you want put your email address in you profile...

    If you want put your email address in you profile and I will send you an email.
    I am always looking for the "right" people and may have some openings coming up in construction.
  20. Replies
    5
    Views
    483

    Thanks Benncool. And all the best to you guys...

    Thanks Benncool.
    And all the best to you guys South of our border on the 4th.:)
  21. Thread: comtrol

    by cousteau
    Replies
    8
    Views
    1,946

    These should keep you busy for a while :D I have...

    These should keep you busy for a while :D
    I have more detailed ones that are too big to post. If you dont get them from someone else here let me know and I will email em.
  22. Replies
    7
    Views
    1,277

    If I dig way deep in my brain I remember working...

    If I dig way deep in my brain I remember working on some Hussmann racks years ago that used LED's for status indicator lights on the rack panel. There were circuit boards associated with powering...
  23. Replies
    11
    Views
    2,576

    You might be thinking about Enviroguard version 1...

    You might be thinking about Enviroguard version 1 where the mechanical SPR is more of a regulator style valve hooked up to a "bulb" or sensor under the condenser. There is a formula for converting...
  24. Replies
    7
    Views
    923

    It might be worth checking the calibration on her...

    It might be worth checking the calibration on her Thermometer and stat.
    I might be off track here.. :confused:but are you asking if this needs a defrost timer. If you are. It does.
  25. Thread: pizza crust

    by cousteau
    Replies
    34
    Views
    5,117

    I spent a few weeks in Italy a couple years ago....

    I spent a few weeks in Italy a couple years ago. The place I stayed at had a book on Pizza. Long story short they use a real simple sauce.
    I just pick up some good quality tinned whole tomatoes. The...
  26. Replies
    29
    Views
    2,178

    Hey Wulfbane, Stick with it you have made a good...

    Hey Wulfbane,
    Stick with it you have made a good choice if trades is what you want to do.
    As a refrigeration mechanic in BC you will be one of the highest paid trades in the country.
    If you excel...
  27. Replies
    11
    Views
    2,576

    Here is a link with the Tyler manulal that...

    Here is a link with the Tyler manulal that explains Enviroguard fairly well.

    www.tylerrefrigeration.com/mechanical/5806448_TylerMSD-ISManual-lowrez.pdf

    You have Enviroguard version 3 which...
  28. Replies
    7
    Views
    846

    I emailed you a manual. Hopefully you get it this...

    I emailed you a manual. Hopefully you get it this file is kind of big.
    I agree with these guys. Sounds like a good opportunity to propose some upgrades.
    Good Luck:)
  29. Replies
    8
    Views
    853

    Are you looking for something specific? I have a...

    Are you looking for something specific? I have a fair bit...but not all.
  30. Replies
    8
    Views
    853

    Here it is And in case anyone is wondering. I am...

    Here it is
    And in case anyone is wondering. I am am not that old. Just have the book.:D
  31. Replies
    8
    Views
    853

    I emailed you a spec sheet. Sombody tell me how...

    I emailed you a spec sheet.
    Sombody tell me how to post PDFS and I will post it.
  32. Thread: help

    by cousteau
    Replies
    20
    Views
    1,325

    Thanks for the reply. I think I am all good so I...

    Thanks for the reply.
    I think I am all good so I will keep waiting patiently.
  33. Thread: help

    by cousteau
    Replies
    20
    Views
    1,325

    Hey Admin, Sounds like you guys are swamped with...

    Hey Admin,
    Sounds like you guys are swamped with this.
    I was not going to bug you but since we are on topic how long does it usually take.
    I applied a few weeks ago.
  34. Replies
    17
    Views
    1,646

    Your setting actually sound close to me if this...

    Your setting actually sound close to me if this system is designed to run at this head pressure and it may be.
    That said I am not familiar with the Encore controller and don't fully understand your...
  35. Replies
    4
    Views
    1,695

    Just a suggestion but you might want to make sure...

    Just a suggestion but you might want to make sure what you are looking at is actually an equalizer line.
    Some Tyler racks have a hot gas return manifold that needs to be piped up to the condenser....
  36. Replies
    20
    Views
    2,284

    Hey RackTech, Hats off to you for sticking with...

    Hey RackTech,
    Hats off to you for sticking with this an putting in a good effort to try and get it fixed but honestly I think your starting spin your wheels here and a fresh pair of eyes might help....
  37. Replies
    10
    Views
    1,915

    The power of ice formation never ceases to amaze...

    The power of ice formation never ceases to amaze me.
    I have a few samples of pipe here that I keep from past failures to show new guys. Its hard to believe until you actually see it.
    Not sure if...
  38. Well I can t say I agree with you guys but I will...

    Well I can t say I agree with you guys but I will leave it at that.
    I suppose the important thing is the common pressure. The flow through the 2vales will probably never be 50/50 no matter how you...
  39. Here is the link. ...

    Here is the link.

    http://www.parker.com/literature/Literature%20Files/Parker.com/Literature/Sporlan/Sporlan%20pdf%20files/Sporlan%20pdf%20090/SD-126.pdf

    And a note quoted from the instructions...
  40. OK. Either I am missing something here or you...

    OK. Either I am missing something here or you guys just do it different than I would.
    I am assuming the following so ignore everything I say if the setup is something different than this.
    These are...
  41. I am curious as to what you would consider the...

    I am curious as to what you would consider the factory setting to be?
    Also I based my comment assuming that these are on the same circuit and piped in parallel for increased capacity.
  42. The important thing is to turn them both the same...

    The important thing is to turn them both the same amount of turns.
    Turn them both all the way in and count the turns as you back them off keeping them the same.
  43. Replies
    13
    Views
    1,607

    Agreed. Seems to be the common opinion here and...

    Agreed.
    Seems to be the common opinion here and I remember so well having this beat into me when I went to school way back when.
  44. Replies
    3
    Views
    875

    I get this question almost every time I hire a...

    I get this question almost every time I hire a new mechanic so I will tell you what I tell them.
    There is no one book that is going to tell you all you need to know.
    The problem is there are so...
  45. Replies
    20
    Views
    2,284

    Its good that you checked all those valves for...

    Its good that you checked all those valves for correct operation but you may have found it easier to take a pressure dop reading on the system when it is in defrost. For that matter take some when...
  46. Replies
    20
    Views
    2,284

    Oops Double post

    Oops Double post
  47. Replies
    20
    Views
    2,284

    Two things I would check. Make sure you have the...

    Two things I would check.
    Make sure you have the pressure differential across actual system. There may be a local system valve or check valve hanging up not giving you the full differential across...
  48. Replies
    18
    Views
    1,197

    A while back (way back)I had some trouble with...

    A while back (way back)I had some trouble with these type of valves. Store wanted to run a couple months without loading the cases. The valves would not settle down with such a light load and a cool...
  49. Replies
    29
    Views
    6,229

    How about a MIG...Just Kidding:D

    How about a MIG...Just Kidding:D
  50. Replies
    29
    Views
    6,229

    Just a guess here but probably a good one....

    Just a guess here but probably a good one.
    Workers dont like the cold air blowing on them so they block the coils with cardboard.

    No air flow
    Floodback
    Liquid Slug
    Bang Bang Bang