    Compatibilty Issue???

    I have a Carrier M/N 50TCQA05A2A5A0A0A0,
    Thermostat is a White Rodgers
    1F85-277
    What's happening is when I make it call for heat it doesn't de-energize the reversing valve, so it continues to...
  2. Replies
    26
    Views
    3,664

    J/C H-10 followed up with Big Blue!

    J/C H-10 followed up with Big Blue!
  3. Replies
    6
    Views
    1,021

    Got the system up and running, Charged 5.5 oz of...

    Got the system up and running, Charged 5.5 oz of R414B and everything looks good! The "bad" compressor was due to the valves bad on it.
    Thanks for everybody's response. You guys definitely make this...
  4. Replies
    6
    Views
    1,021

    R-12 replacement

    I have an Reach down refer box that was used as a "Coca-Cola" service box made by Cornelius and It has a bad compressor. And what I wanted to know only because I have a cylinder of it, Can R-414B be...
  5. Thread: Tool List

    by refer1
    Replies
    19
    Views
    3,840

    Tool List

    Never had this asked before until another Contractor friend had one of his tech's truck broken into, wiped out all the tools companies and personal.

    Do you think there is a basic tool list every...
  6. Replies
    10
    Views
    1,318

    Good luck with this one

    Have had good luck with this Recovery unit:

    CPS Products CR700
    Cyclone Oil-Less Refrigerant Recovery Machine
  7. Thread: low suction

    by refer1
    Replies
    7
    Views
    1,324

    eek!

    kinda what alot of us look like after all those drive-thru McDonald egg-McMuffins!

    Interesting to see what an oil analysis would show on that!
  8. Replies
    1
    Views
    672

    check this out

    It would be great if you had even the a couple of digits of the model number. If you get them try this website.
    You might just have to go through lot of literature but hope this helps.
    ...
  9. Replies
    108
    Views
    10,085

    Star Test

    Took the test last year. passed it but no change in status, still journeyman.
    Company pushes the fact that they have Star Certified techs.
    I heard that some guys that had a Serviceman 5 or 1 status...
  10. Replies
    7
    Views
    1,813

    TurboCor Inside!

    That Mcquay chiller has the TurboCor compressor, I seen a demonstration on it. It truly is an amazing compressor.
    www.turbocor.com
  11. Replies
    11
    Views
    2,746

    Hitachi Compressor in a Mammoth

    This 6002SC-H is in a Mammoth unit M/N VVW-801-GXL

    Not so much of a problem as inquiry of how to properly charge this system.
    I called ACCS which they told me based on a superheat from 9-27...
  12. Replies
    3
    Views
    2,110

    What is the amount of POE oil for a complete...

    What is the amount of POE oil for a complete charge on a 6005 SC-Z take?

    Thanks for your help!
  13. Replies
    23
    Views
    6,808

    I see the 3-wheeler is locked up! You need to put...

    I see the 3-wheeler is locked up! You need to put a chain on that unit or it might disappear on you too!!!