  1. Replies
    28
    Views
    2,407

    I respectfully disagree with Beenthere about the...

    I respectfully disagree with Beenthere about the minimal SEER increase by adding a TXV valve. I indeed find that with those cheaper, very small condensor 10 SEER systems the efficiency gain is lower,...
  2. Replies
    28
    Views
    2,407

    Add TXV valve

    You can also talk with your service professional about the possibility to replace the metering device with a TXV valve.
    It will cost you some money, but it will increase the SEER rating from 10 to...
  3. Replies
    21
    Views
    1,941

    VS blower

    Iím not that familiar with Trane units. If you want to go with a VS air blower, I would definitively make sure Iím getting one with a more efficient ECM motor (versus PSC).
    Maybe Trane only uses...
  4. Replies
    88
    Views
    7,439

    R22 drop-in replacement

    For the R22 believers, there is now a drop-in replacement. It is called R-434A (or RS-45). It is just recently approved by ASHREA.
    Read...
  5. Replies
    20
    Views
    10,854

    I hope I don't hurt anybody's feelings, I'm not a...

    I hope I don't hurt anybody's feelings, I'm not a firm believer in heat pumps for heating.
    I'm sure that the claims they make are valid (e.g. COP 2.8). This makes that for every KWh you're using and...
  6. Replies
    100
    Views
    17,825

    I live in TX myself, I believe strongly in the...

    I live in TX myself, I believe strongly in the possitive effect of RB.
    BUT, does anybody knows something about the effect on the roofing material (e.g. asphalt shingles). It must be that the roof...
  7. Replies
    1
    Views
    569

    Did anybody ever hear about 'Ikon-B"?

    I was reading some articles and stumbled onto a pdf explaining the benefits of a new refrigerant Ikon B.

    It is supposed to be a drop-in replacement for R22 and yields a better cooling efficiency....
  8. Replies
    69
    Views
    3,706

    [QUOTE=bustawrench1;1495508]My total sales for...

    [QUOTE=bustawrench1;1495508]My total sales for 2005 were 1.4 Million.

    That was on top of the 2300 hours I billed out for.

    The first quarter of 2006 I sold $300,000 and billed 600 hours.
    ...
  9. Replies
    20
    Views
    1,834

    Davidr my mistake. I also believe that duct...

    Davidr my mistake. I also believe that duct losses are far from neglectable. My question should have been:

    Chillbilly, could you share the parameter settings used to come to the 4%: duct length...
  10. Replies
    20
    Views
    1,834

    Duct losses

    Interesting discussion!
    I have a hot attick, >110F in the Summer.
    Ducts have a length between 10 ft and 40ft, only R3.
    I once measured the temperature difference between a return grill and an...
  11. Replies
    20
    Views
    1,834

    What is the value of the SEER rating?

    I can't help it, the more I think and read about it the more I doubt the value of the SEER rating for people living in Southern states.

    SEER is a kind of averaged efficiency rating for an...
  12. Jim, I'm afraid you're off and not even a little...

    Jim, I'm afraid you're off and not even a little bit.
    The house is cooled by boiling of the liquid refriggerant in the evaporator coil. With R22 and 70psi it boils around 34F, so plenty of...
  13. Well, I don't give up that easily... I should...

    Well, I don't give up that easily...
    I should have said "I would say, for the time being the water misting myth is busted WITH MY SYSTEM CONFIGURATION", meaning:
    - my freon charge set for a...
  14. I'm sorry typo: Suction pressure before...

    I'm sorry typo:

    Suction pressure before misting: 80 psi (not 62.5)
  15. I want to thank everybody for their...

    I want to thank everybody for their contributions/thoughts.

    I started this 'project' on my old airco system (11 year old). Even if the condensor is wasted after a couple of years because of...
  16. I have an 11 year old YORK split airco system, 3...

    I have an 11 year old YORK split airco system, 3 ton. No TXV valve.

    1. I want to increase the efficiency of my HVAC system. I put some 12 water misters around the outdoor condensing coil. Water...