Type: Posts; User: jgb123

Search: Search took 0.00 seconds.

  1. Replies
    55
    Views
    6,593

    heres an Idea if you have a electrostatic filter....

    heres an Idea if you have a electrostatic filter. Keep a pleated filter on hand and put it in place every time the filter is washed allowing the filter dry. A soapy cleanser should be used...
  2. Replies
    3
    Views
    1,360

    what about duel fuel my understanding it is one...

    what about duel fuel my understanding it is one of the cheapest configurations when it comes to energy consumtion. Gas furnace{variable speed} with heat pump condenser and coil to match?
  3. Replies
    7
    Views
    990

    i meant to ask what are the different processes...

    i meant to ask what are the different processes of a heat pump compared to a standard cooling system?
  4. Replies
    7
    Views
    990

    what is the diference between a heat pump and...

    what is the diference between a heat pump and your standard condenser?
  5. Replies
    13
    Views
    7,805

    looks like i opened up a can of worms. i...

    looks like i opened up a can of worms. i appreciate all the information though.
  6. Replies
    6
    Views
    935

    thats what i thought, thanks for the info

    thats what i thought, thanks for the info
  7. Replies
    67
    Views
    4,518

    Thank you for the info, so the run capactor...

    Thank you for the info, so the run capactor remains in the circuit to keep compressor running after the compressor reaches full speed, correct. would this be a way of explaining this on a test, still...
  8. Replies
    67
    Views
    4,518

    So what is the purpose of a run capacitor and a...

    So what is the purpose of a run capacitor and a start capacitor in a condensing unit in relation to the compressor? did not think it absobs heat from the motor.
  9. Replies
    6
    Views
    935

    thank you for the info

    thank you for the info
  10. Replies
    67
    Views
    4,518

    Re: capcitors

    meant to ask " can anyone else verify this as being correct?"
  11. Replies
    6
    Views
    935

    what winding is open when compressor overheats,...

    what winding is open when compressor overheats, c-r,r-s,or s-c?
  12. Replies
    67
    Views
    4,518

    capcitors

    can any one verify this info as being correct?
  13. Replies
    7
    Views
    9,852

    ohming compressor

    thank you for the information, very usefull
  14. Replies
    67
    Views
    4,518

    what is mechanical purpose of the run capacitor...

    what is mechanical purpose of the run capacitor and the start capcitor?
    Start provides starting torqe and run capacitor provides current for compressor operation. is this correct?
  15. Replies
    7
    Views
    9,852

    when checking ohms on a compressor the highest...

    when checking ohms on a compressor the highest reading is between run and start, middle reading start and common, and lowest reading between common and run. is this correct?
    how does it read on the...