  1. Replies
    9
    Views
    691

    I take it this is a bad design.Adding baffles to...

    I take it this is a bad design.Adding baffles to reduce airflow to save manufacturing costs.I am looking into natural gas.(line is appx.350' away) and hopefully get rid this fuel hog furnace.
  2. Replies
    9
    Views
    691

    Thanks beenthere.I have seen low firing rate...

    Thanks beenthere.I have seen low firing rate baffles mentioned after searching it.This is the only PDF I have...
  3. Replies
    9
    Views
    691

    Here is wiring diagram:

    Here is wiring diagram:
  4. Replies
    9
    Views
    691

    No,All unit dimensions,filter & duct openings are...

    No,All unit dimensions,filter & duct openings are identical.It almost has to be electrical.
  5. Replies
    9
    Views
    691

    What Am I Missing?

    Two Luxaire Furnaces- Model #PBFMD12F08501A and Model#PBFMD12F05501A.Both Furnaces Use The Same Blower Motor And Wheel With Different Airflow Ratings.Something Has To Regulating Flow On The Smaller...
  6. Thats a little better.Thank you.

    Thats a little better.Thank you.
  7. Supply (sorry).

    Supply (sorry).
  8. Is the EL of this box on box equal to 200 feet?

    It seems a little much?
  9. Replies
    19
    Views
    1,164

    Thanks for the link hvacrmedic.I dont intend to...

    Thanks for the link hvacrmedic.I dont intend to do modifications required as I dont have tools or knowledge of setting up.I am trying to determine (using manual J&D and the great knowlede of the guys...
  10. Replies
    19
    Views
    1,164

    Need eqiv. lengths for: 3924 supply trunk...

    Need eqiv. lengths for: 3924 supply trunk tee/3892 plenum/3925 trunk/3920 pan to trunk/3893 trunk to plenum.Also for 8"x8"x8" tee.Pictures in my album.Thanks for any help.
  11. Replies
    19
    Views
    1,164

    Yes it has me very confused reading it.Differrent...

    Yes it has me very confused reading it.Differrent wheels makes sense.I will post some pictures of data in my album.Thanks for all your help.
  12. Replies
    19
    Views
    1,164

    Blower is 1/3 H.P. 10x9 wheel.Would rpm numbers...

    Blower is 1/3 H.P. 10x9 wheel.Would rpm numbers help?If you are referring to an earlier post it is the 85,000 ( larger blower).
  13. Replies
    19
    Views
    1,164

    Cooling is 2-ton.Coil rating at 800 CFM is .16...

    Cooling is 2-ton.Coil rating at 800 CFM is .16 wet/.16 dry.Furnace BTU is correct.Return grilles are hart and cooley/661/14"x6".Supplies are h&c/406/18".Low speed @ .8 is 835 cfm. ...
  14. Replies
    19
    Views
    1,164

    O.K. If System design is .5 Static pressure and...

    O.K. If System design is .5 Static pressure and lets say total longest Return and Supply runs are approximately 500 feet that would give duct system a .1 value.Is this correct? Anyone have a link to...
  15. Replies
    19
    Views
    1,164

    So 1000 CFM would be a close duct design...

    So 1000 CFM would be a close duct design value?(Supply 8"x30" @ 700 FPM.)(Return 8"x36" @ 600 FPM.)Are these numbers close?
  16. Replies
    19
    Views
    1,164

    55-85 F

    55-85 F
  17. Replies
    19
    Views
    1,164

    Thanks gravity.I am need to establish CFM to...

    Thanks gravity.I am need to establish CFM to ensure my ducts are correctly sized before getting system fine tuned.I thought a lower BTU would require a little less air flow.Just need a number to...
  18. Replies
    19
    Views
    1,164

    The 72,000 is listed as an alternate output.The...

    The 72,000 is listed as an alternate output.The furnace manual only shows 55/85/100/&125 data.Beckett oil burner manual shows 55/85/100/125/170.Furnace manual factory set heating speeds are...
  19. Replies
    19
    Views
    1,164

    Airflow Required?

    What is the required airflow for 72,000 BTU oil furnace.
  20. Replies
    27
    Views
    3,217

    Furnace Return temp. 2' before filter is 65....

    Furnace Return temp. 2' before filter is 65. Supply Temp 1'after plenum is 140.
  21. Replies
    27
    Views
    3,217

    Posted some pictures in my album.Im sure you guys...

    Posted some pictures in my album.Im sure you guys have seen worse.
  22. Replies
    27
    Views
    3,217

    Any recommendations on Heat Pump lockout...

    Any recommendations on Heat Pump lockout temp?Equipment CPH settings?Is Furnace to Big?My contractor got lucky with sizing my A.C. It seems alot of contractors are leaving the V out of HVAC.
  23. Replies
    27
    Views
    3,217

    Did a heat load calc.Very easy program.Well worth...

    Did a heat load calc.Very easy program.Well worth every penny.Results are:Outside: Summer96/Winter11 Inside:Summer75/Winter72. Heat Gain 21,223 Heat Loss 38,939.
  24. Replies
    27
    Views
    3,217

    Motor is 1/3 H.P. (10x9 wheel).Heat Pump...

    Motor is 1/3 H.P. (10x9 wheel).Heat Pump installed 6 Months ago.I have considered lowering furnace BTU to alternate 72,000 BTU by changing nozzle as per rating. Furnace is 80% eff.Could I then reduce...
  25. Replies
    27
    Views
    3,217

    Thanks udarrel.I have read many of your articles...

    Thanks udarrel.I have read many of your articles outside of this site.You would think coil pans would have tapered bottoms to funnel air up into the A-coil.(This was my "ramp" theory).Blower speed ...