Search:

Type: Posts; User: bcrum51

Search: Search took 0.00 seconds.

  1. Replies
    40
    Views
    4,361

    Also I know some splits use 36v for communication...

    Also I know some splits use 36v for communication and require shielded wire just shooting in the dark here for you
  2. Replies
    21
    Views
    3,189

    LG use to make cooling only units but have since...

    LG use to make cooling only units but have since stopped only heat pumps now
  3. Replies
    13
    Views
    1,677

    I think you hit it right on the head

    I think you hit it right on the head
  4. Replies
    27
    Views
    1,918

    new ac's to charge you just hook up ur gauges and...

    new ac's to charge you just hook up ur gauges and u can charge with out touching the service port a king valve has to be back seat to achieve a reading I believe i dont see them that often
  5. Thread: Piston sizing

    by bcrum51
    Replies
    8
    Views
    1,347

    All goodman coils have a r22 piston in it but all...

    All goodman coils have a r22 piston in it but all their condensing units come with the piston that is to be used with that unit always take the piston off the unit and install in coil
  6. Replies
    21
    Views
    3,189

    yellow jacket has adapters that they screw you on...

    yellow jacket has adapters that they screw you on pricy things
  7. Replies
    6
    Views
    848

    and no because it has been defective from the...

    and no because it has been defective from the start i would say after the second board went bad i would have not replaced it the 3rd time till i could figure out why the board was shooting craps
  8. Replies
    6
    Views
    848

    first Id call rheem and say what the heck is the...

    first Id call rheem and say what the heck is the deal here and get some tech support
  9. Replies
    27
    Views
    1,918

    dont feel bad first time i ran into a king valve...

    dont feel bad first time i ran into a king valve i had to call a more experienced tech he laughed and me and informed me it was the way we did it "back in the day" haha
  10. Replies
    13
    Views
    1,677

    thanks anyway appreciate the help still on the...

    thanks anyway appreciate the help still on the fence about even doing it
  11. Replies
    12
    Views
    1,305

    can i get an amen

    can i get an amen
  12. Replies
    22
    Views
    2,454

    westinghouse would have got my vote i would have...

    westinghouse would have got my vote i would have been wrong
  13. Replies
    40
    Views
    4,361

    hmmm not real familiar with fujitsu's operating...

    hmmm not real familiar with fujitsu's operating process i deal with LG stuff maybe call tech support
  14. Replies
    40
    Views
    4,361

    read the install manual it will probably tell you

    read the install manual it will probably tell you
  15. Replies
    13
    Views
    1,677

    What was your total occupancy ??

    What was your total occupancy ??
  16. Replies
    12
    Views
    1,305

    True boxes seem to have an issue with clogged cap...

    True boxes seem to have an issue with clogged cap tubes I replaced one once that was so clogged it was pulling a vacuum on the suction side pulled the cap tube full of black stuff
  17. Replies
    27
    Views
    1,918

    i would just charge the unit by calculating SH SC...

    i would just charge the unit by calculating SH SC as per manufacturers spec on the info plate or to the standard SH SC if not present on the plate
  18. Replies
    13
    Views
    1,677

    thats what i was thinking 2 splits on each end of...

    thats what i was thinking 2 splits on each end of the building 2 3 ton units any idea of heating btu's i was think 100k total out btu so 2 60k 95% furnaces???
  19. Replies
    27
    Views
    1,918

    blue hose low side red hose high side yellow hose...

    blue hose low side red hose high side yellow hose gas jug open gas jug purge air from yellow hose open suction side of manifold charge by superheat or subcooling. are your units fitted with a king...
  20. Replies
    27
    Views
    1,918

    you are charging though the low side right just...

    you are charging though the low side right just outta curiosity
  21. Replies
    13
    Views
    1,677

    Banquet Room Sizing

    Ok this is my first "commercial" job its new construction. One of those friends that we all have when they need a job done called me today...:gah:
    He is adding a new addition to his restaurant its...
Results 1 to 21 of 21
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event