  1. Replies
    11
    Views
    906

    You should be able to see red and yellow leds on...

    You should be able to see red and yellow leds on the CVTPRO. Be cautious hooking up transformer. If you are getting 24 vac already and connect with dc voltage, it will let the smoke out of the...
  2. Replies
    11
    Views
    906

    Go to your preferences and allow private messages...

    Go to your preferences and allow private messages to allow email
  3. Replies
    11
    Views
    906

    The issue at this time was that my computer COM...

    The issue at this time was that my computer COM port was not being shared through to my virtual machine. Make sure you have the HVAC Pro 8.08b patch installed also--this may also cause error.
  4. Replies
    3
    Views
    381

    That was it. Thanks so much. Now, how do I...

    That was it. Thanks so much. Now, how do I release overrides on the system?
  5. Replies
    3
    Views
    381

    Landis & Gyr 600 Endless Loop

    We have a customer with Landis & Gyr 600 system controlling their facility. We are not able to access the system because it keeps looping the same information: begins to list controller information...
  6. Replies
    11
    Views
    906

    I am connecting to the zone bus. I am also using...

    I am connecting to the zone bus. I am also using AS-CVTPRO. This is the same way I've connected for several years and have not had any issues with connecting.
  7. Replies
    11
    Views
    906

    HVAC Pro Communications Error

    Been using HVAC Pro 8.08b for several years without problems until recently. I am getting this communications error. Thought it may be my Digi Edgeport USB to Serial converter, so I got another, but...
  8. Replies
    11
    Views
    943

    After reboot, all is well. Controls 101: start...

    After reboot, all is well. Controls 101: start with resetting controller! In this case, the JCI AHU controller was fine, but the FX JACE had the problem. Thanks all for suggestions.
  9. Replies
    11
    Views
    943

    I have done an emergency level override to auto...

    I have done an emergency level override to auto and I have also checked and it is not someone who's putting the overrides in, and also there are no links to this point on input 8.
  10. Replies
    11
    Views
    943

    [QU OTE=digo;16699441]Look at the link sheet,...

    [QU OTE=digo;16699441]Look at the link sheet, probably another point linked to it that is overridden.
    emergency overrides at level 1, overrides at level 8, and also min on/off timers enforced at...
  11. Replies
    11
    Views
    943

    I tried that...actually even Emergency Auto, but...

    I tried that...actually even Emergency Auto, but point remains true.
  12. Replies
    11
    Views
    943

    FX40 Boolean Writable

    425831

    Having a problem with a boolean writable point. Seems that in8 is stuck on True and there is not a way to 'reset'. I have searched and there are no links to input, so I am uncertain of...
  13. Replies
    5
    Views
    989

    Yes, it is a VAV

    Yes, it is a VAV
  14. Replies
    5
    Views
    989

    Thank you, that is great information. Is it...

    Thank you, that is great information. Is it possible to tell if this UCM is comm4? 385621
  15. Replies
    5
    Views
    989

    Trane comm3 or comm4???

    Looking at a Niagara AX integration with Trane controls. First, is it true that there are currently only AX drivers for comm4? Second, how can I tell from looking at the trane controllers (UCM,...
  16. Replies
    18
    Views
    1,812

    Great controllers with excellent customer service!

    Great controllers with excellent customer service!
  17. I looked for the manual, but could not find. ...

    I looked for the manual, but could not find. Could someone please email it to me? Thanks in advance.
  18. Replies
    8
    Views
    744

    I will send you the file...where would I find...

    I will send you the file...where would I find your email info?
  19. Replies
    8
    Views
    744

    I am using OrcaView V3.30 and I can see all the...

    I am using OrcaView V3.30 and I can see all the controllers on the system as well as this one except my 'damper program PG14' is faulted and I cannot open that specific program. The rest of the...
  20. Replies
    8
    Views
    744

    Delta Controls DVC-V304

    I've got a DVC-V304 V3.30 which has the damper program in 'fault'. Upon attempting to view program I get a fault message--"Unable to open the requsted object" I've tried reinstalling the program,...
  21. Replies
    17
    Views
    1,356

    thank you!

    thank you!
  22. Replies
    17
    Views
    1,356

    Not necessarily true.....I've witnessed smoke...

    Not necessarily true.....I've witnessed smoke leaving those little components once upon a time--don't care to witness it again :oops:. May have been a faulty controller or maybe a bad connector. ...
  23. Replies
    17
    Views
    1,356

    So then I DO connect to the UNT using 8-6 pin...

    So then I DO connect to the UNT using 8-6 pin connector via the AS-CBLPRO-2 w/o power as power is supplied from the controller: is that correct?
    Then, the AHU I could get by with using the straight...
  24. Replies
    17
    Views
    1,356

    JCI UNT & AHU Zone bus connnections

    First....In order to connect to a UNT controller with AS-CBLPRO-2, I would use an 8-6 pin connector and no external (transformer) power supply would be necessary when connecting to the controller via...
  25. Replies
    4
    Views
    1,083

    Thanks for your help. I did override the point...

    Thanks for your help. I did override the point and saw the timer count up to 180 seconds, but I believe I started with the box closed. The original controller program for AV3 had a value of 415 and...
  26. Replies
    4
    Views
    1,083

    No stupid questions...I installed them as I found...

    No stupid questions...I installed them as I found them. I was unable to tell which was high and low: they seemed about the same. Figured when I return I will have a manometer with me. Guess my...
  27. Replies
    4
    Views
    1,083

    Delta Controls DVC-V304

    Replaced a DVC-V304 v3.30 today and the airflow on the controller now reads 0 cfm even though there is airflow. I plan to return and check with a manometer, but what is the process for calibrating a...
  28. Honeywell Webvision XL15C (W7760C) Programming Support

    308011
    Where can I find support literature which describes various functions and terminology used for programming a Honeywell XL15C (W7760C) controller via Webvision?
  29. Replies
    4
    Views
    1,258

    Actually, I wished it was hooked up to a JACE: ...

    Actually, I wished it was hooked up to a JACE: the programming seems much more straight forward than Honeywell terminology. shovelhead, would you email me? Got a favor of you. Have not yet found...
  30. Replies
    4
    Views
    1,258

    I believe the controller is hooked up to...

    I believe the controller is hooked up to Webvision, however I do have Lonspec, just not much experience with either.
  31. Replies
    4
    Views
    1,258

    Honeywell Excel 15 W7760C

    I am looking for information to assist me with programming on a Honeywell W7760 controller. I have a system engineering manual for this Excel 15 W7760C controller, but is seems limited on the...
  32. Replies
    17
    Views
    1,863

    I did not get your email, but that is alright. ...

    I did not get your email, but that is alright. Customer was able to locate PSI and I was able to access controller logic and resolved their current issue. I am certainly interested in getting more...
  33. Replies
    17
    Views
    1,863

    Niagara AX is what we will install at one...

    Niagara AX is what we will install at one customers site. The other customer has issues with a MZ2 controlling a RTU right now. My interest right now is to take a look into the MZ2. However, I...
  34. Replies
    17
    Views
    1,863

    Microzones PSI XPSI

    I now have several customers who have Network 8000 controls installed on their site, but have been abandoned by their service provider. Unfortunately, most do not have budgets that allow them to...
  35. Replies
    2
    Views
    1,178

    FX40 Niagara AX JCI AHU controller question

    I have an Johnson Controls AHU controller with it's time clock off a few hours. First, is it possible to adjust it via the embedded Workbench?

    Second question, shouldn't the time sync service...
  36. Thread: Trane software

    by mikeul
    Replies
    1
    Views
    1,132

    Trane software

    I have a customer who have Trane equipment on a couple sites: one has a CCP3 controller and another is using Tracer Summit with a BCU with TUC controller. I worked on these systems in the past, but...
  37. Replies
    4
    Views
    584

    Thank you.....the OS on this laptop is Win98.

    Thank you.....the OS on this laptop is Win98.
  38. Replies
    4
    Views
    584

    JCI Zone Terminal

    I have a Johnson Controls Zone Terminal Unit that I am trying to configure. I am attempting to install ZTPro along with HVAC Pro, but the ZTPro is 'greyed out' :gah: and I am unable to check to...
  39. Replies
    4
    Views
    709

    You guessed correctly...worked as you suggested. ...

    You guessed correctly...worked as you suggested. The FX appears to have tremendous capabilities. What educational resources are available to better understand the controller? Are most Tridium...
  40. Replies
    4
    Views
    709

    Tridium FX Custom Control

    I'm attempting to put together custom control logic on a Tridium FX60 but have an error 'fault/stale' (see photo) The values are coming through, but each point that I drag into the custom control...
  41. Replies
    3
    Views
    1,542

    Worked perfectly, thank you.

    Worked perfectly, thank you.
  42. Replies
    3
    Views
    1,542

    Tridium FX JACE and KMC

    I have a customer site with a JCI FX controller bringing in points from a KMC controller via BACnet. Customer would like to lower the setpoint. The KMC controller has a range on the KMD stat which...
  43. Replies
    6
    Views
    1,610

    Thank you for the information; worked perfectly. ...

    Thank you for the information; worked perfectly. With the software embedded, is additional software needed for configuration? If an FX were to lose it's 'mind', do I need utility software? I did...
  44. Replies
    6
    Views
    1,610

    Facility Explorer FX60

    I have an FX60 at a new cutomers site and have a couple questions. First, how can I get graphic image from my local computer and install into the graphic folder within the FX60 that I am connected...
  45. Replies
    7
    Views
    1,387

    I went back and replaced the single phase motor....

    I went back and replaced the single phase motor. As far as the 3 phase motor, L1 was feeding through P66 serving as 1st ph, L2 was 2nd ph, L3 was fed from capacitor off of L2.

    I rewired...
  46. Replies
    7
    Views
    1,387

    Liebert condenser with a P66 speed controller

    Went to a site today and found a Liebert condenser with 2 motors: 1 single phase motor which is normally controlled with a JCI P66 series speed controller and a 3 phase motor which is controlled by...
  47. Thread: UPCM edit

    by mikeul
    Replies
    6
    Views
    828

    Where can I get upcm and pcm edit?

    Where can I get upcm and pcm edit?
  48. Thread: UPCM edit

    by mikeul
    Replies
    6
    Views
    828

    Can Rover software be used to configure UPCM or...

    Can Rover software be used to configure UPCM or PCM controllers?
  49. Thread: UPCM edit

    by mikeul
    Replies
    6
    Views
    828

    I do not have Summit on my laptop. Also, there...

    I do not have Summit on my laptop. Also, there is no executable files in the folder. Since it is a DOS program, I don't understand how to 'run' it.
  50. Thread: UPCM edit

    by mikeul
    Replies
    6
    Views
    828

    UPCM edit

    We have recently taken over a contract which has Tracer Summit. There are UPCM controllers which I have access using UPCM edit software through Summit. I would like to have the software on the...