    Correct Carriers watersource heat pumps are made...

    Correct Carriers watersource heat pumps are made by climatemaster
  2. Thread: ComfortVIEW...

    by ???
    Replies
    4
    Views
    998

    comfortview will not work with gen 1,2,3 vvt...

    comfortview will not work with gen 1,2,3 vvt parker systems. the program for that is DOS based. and yes you will have a hard time finding it and if you do you would need a dos computer ect. ...
  3. Carrier and Bryant are the same company made on...

    Carrier and Bryant are the same company made on same asym. line the carpet thing no way that is the cause what is the m# of coil you have
  4. Thread: Carrier FIOP Codes

    by ???
    Replies
    10
    Views
    2,777

    product data book will break down your unit but...

    product data book will break down your unit but will not give you fiop options
  5. Thread: Carrier FIOP Codes

    by ???
    Replies
    10
    Views
    2,777

    to break down your unit you have low heat (D) 12...

    to break down your unit you have low heat (D) 12 1/2 ton (014) alternate motor (A)

    6 (460 volt) 1 (series) 1 (packing) -- (no fiop)
  6. Thread: Carrier FIOP Codes

    by ???
    Replies
    10
    Views
    2,777

    48TFD014-A-611-- the 6 is the voltage 1 is...

    48TFD014-A-611--

    the 6 is the voltage 1 is the series the 1 at end is packaging the optional codes would be at the end but you do not have any the other dashes are also other option/motors ect...
  7. Replies
    20
    Views
    1,466

    if you have the 48tc unit with the multi...

    if you have the 48tc unit with the multi protocall board in it you will need a special hand held device to program it. it also will need to run on a ddc front end system/sensors. this is only if it...
  8. Replies
    22
    Views
    3,459

    the 58mvcis a three stage furnace if you would....

    the 58mvcis a three stage furnace if you would. question do you have the infinity user interface for a thermostat? if so make sure your contractor sets it up the correct way. if not what type of...
  9. Carrier has a new line of A/C and heat pumps out....

    Carrier has a new line of A/C and heat pumps out. You can purchase 13,14,17,21 SEER condensing units. Now you cant just buy the condensing unit and expect to get the SEER the equipment must be a...
  10. Replies
    5
    Views
    1,082

    the E7 is compressor malfunction it triped at...

    the E7 is compressor malfunction it triped at some point. If you clean the condenser and find that you have not recived E7 you may have solved the issue it need a cleaning prob. high head.. You...
  11. Thread: Carrier rooftop

    by ???
    Replies
    28
    Views
    3,506

    Acutrol refrigerant metering system test run a/c...

    Acutrol refrigerant metering system test run a/c turn indoor fan off watch header on acutrols what ever freezes your good the ones that are not frosted are bad/blocked
  12. Thread: Carrier rooftop

    by ???
    Replies
    28
    Views
    3,506

    Replace the coil... The new coil will have the...

    Replace the coil... The new coil will have the header with accutrols in it do not attemp to do each orfice. You must have a tj or >>>
  13. Replies
    6
    Views
    668

    Filters: depending on what filter you choose to...

    Filters: depending on what filter you choose to use there is a pressure drop across filters and if it is to much it will not allow the system work to its best.
    without getting to technical if you...