    Is there a way of communicating some of these...

    Is there a way of communicating some of these issues directly to the Carrier R&D group? Talking to a Carrier tech over the phone most likely wouldn't get the message passed on. There are some...
  2. Replies
    16
    Views
    1,874

    Thanks jrbenny. It seems to work, the system...

    Thanks jrbenny.

    It seems to work, the system is now adjusting the target Heat Humidity setting as required. There might however be a simpler way for this control to present itself to the users....
  3. Replies
    16
    Views
    1,874

    jrbenny, I tried your advice, lowered the...

    jrbenny,

    I tried your advice, lowered the Heat Humidity setting to 3 squares and yes the Auto Heat Humidity setting finally moved below 45%!

    But...when I set the Heat Humidity to 15% the...
  4. Replies
    16
    Views
    1,874

    There are 7 squares visible on both the Auto and...

    There are 7 squares visible on both the Auto and Manual setting.

    When you change from Manual to Auto you can see the setting % change from 35% to 45%, bars remain the same.

    The Honeywell...
  5. Replies
    16
    Views
    1,874

    Outdoor temp is currently 31F or about 0C. ...

    Outdoor temp is currently 31F or about 0C.

    Outdoor sensor is installed outside in the correct position.

    I have just set the Humidifier back to Auto as you suggested. The Humidity setting...
  6. Replies
    16
    Views
    1,874

    I'm having some issues with the Infinity control...

    I'm having some issues with the Infinity control and the "Auto" setting of the Humidifier.

    During the initial setup the Heat Humidity Setting was set at 45% in the "Auto" position. As this was...
  7. Replies
    16
    Views
    1,684

    58 MVP Troubleshooting Guide Fault Code 13:...

    58 MVP Troubleshooting Guide

    Fault Code 13: "Limit Switch Lockout - This fault indicates the limit switch has tripped 10 times in a row in high fire or 3 times in a row in low fire during a call...
  8. Replies
    19
    Views
    1,808

    You are exactly right! Not sure how the heat...

    You are exactly right! Not sure how the heat humidity mode works without a humidifier. Let us know how you do without one.

    The cooling mode humidity screen actually does say "Dehumidify", Thorton...
  9. Replies
    19
    Views
    1,808

    Thorton, The Infinity humidity settings for...

    Thorton,

    The Infinity humidity settings for the heating and cooling modes are set separately.

    The heating humidity may be set between 5% to 45%. It also allows the user to select the Auto mode...
  10. Replies
    19
    Views
    1,808

    The Infinity controller is quite a bit different...

    The Infinity controller is quite a bit different from the Thermidistat, at least from what we users see. The humidity settings for both heat and cool are user selectable and the fan settings need to...
  11. Replies
    2
    Views
    1,104

    Thanks for the reply, appreciate it. The...

    Thanks for the reply, appreciate it.

    The reading material I have found for the Infinity controller indicates you can hook up as many as 4 remote room sensors and the system will average the temp...
  12. Replies
    2
    Views
    1,104

    Let me try this one more time....a different way....

    Let me try this one more time....a different way.

    Has anyone used the Carrier remote room sensors with the Infinity system?

    Do they work well when the Infinity controller uses the average of...
  13. Replies
    0
    Views
    677

    We had the Infinity system installed in our new...

    We had the Infinity system installed in our new house last summer. We new the cost wouldn't allow us to put in zoning or an ERV until the spring, but we wanted the best.

    The question is, would...
  14. Replies
    20
    Views
    2,281

    Sorry that should read dehumidifier not...

    Sorry that should read dehumidifier not humidifier!!
  15. Replies
    20
    Views
    2,281

    Coil is CC5AXA, 2 1/2 ton, paired with a 38TDB...

    Coil is CC5AXA, 2 1/2 ton, paired with a 38TDB 3ton, 58MVP 80.

    Yes the low/no AC load days are a bit of an issue, but I'm not sure if a humidifier is necessary or just more knowledge of how the...
  16. Replies
    20
    Views
    2,281

    I also own an Infinity system. Whenever I put the...

    I also own an Infinity system. Whenever I put the fan on low instead of auto the humidity level increases by as much as 4% in a 4 hour time period. I'm starting to wonder if the fan being set on...
  17. Replies
    17
    Views
    1,523

    Thanks everyone for your input. It is...

    Thanks everyone for your input. It is appreciated. I don't know of anywhere else where we can find this much HVAC knowledge given so generously. Hopefully I will be able to repay somehow, someday.
    ...
  18. Replies
    17
    Views
    1,523

    Okay, now I'm confused! Carrier 58MVP080-F,...

    Okay, now I'm confused!

    Carrier 58MVP080-F, inside or outside air for combustion? Carrier manuals say outside, some installers are saying inside, others outside.

    The installer of this system...
  19. Replies
    17
    Views
    1,523

    Thanks everyone for taking the time to respond. ...

    Thanks everyone for taking the time to respond.

    It sounds like combustion air from the outside is the way to go. The furnace is working the way it is but I've always wondered.

    The installer...
  20. Replies
    17
    Views
    1,523

    Quick question about the Carrier 58MVP combustion...

    Quick question about the Carrier 58MVP combustion air setup. The furnace it replaced (4 year old Carrier builder's model) did not use outside air for combustion, so the installer did not change this...
  21. Replies
    9
    Views
    833

    Thanks for the response! nascar, I believe...

    Thanks for the response!

    nascar, I believe dash is right, it was chrisp who indicated he was from the Carrier engineering group.

    jrbenny, thanks for the input. What you say is pretty well what...
  22. Replies
    9
    Views
    833

    Hi everyone. I am a new member here as well as a...

    Hi everyone. I am a new member here as well as a new Infinity system owner of a few months.

    The system consists of a 38TDB, 58MVP, Infinity D01 controller and a fan powered humidifier. The...
Results 1 to 22 of 22
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event