Search:

Type: Posts; User: hvac_czar

Page 1 of 19 1 2 3 4

Search: Search took 0.03 seconds.

  1. Absolutely... Way back in the day all we got was...

    Absolutely... Way back in the day all we got was "Here's your beeper, make it happen"... I spent many a terrified early morning hour alone in a boiler room, that is not the goal with our greenhorns...
  2. Thanks Coolwhip, True about the streets! All...

    Thanks Coolwhip,

    True about the streets! All of them old cow paths!

    Still looking for the right tech...

    Lots of kids here go to "for profit" tech schools (ITT Tech, etc.) and find on...
  3. "is boston expensive place to live? it seems to...

    "is boston expensive place to live? it seems to be an expensive place to live being historic and university town and such? I've been there in the summer, it's jammed pack with tourists."



    ...
  4. Got to have a little humor!

    Got to have a little humor!
  5. If you do, look me up... Will be our busiest...

    If you do, look me up... Will be our busiest Winter ever on the construction side and service always follows construction here.
  6. Thanks fellas... The trades have been awesome for...

    Thanks fellas... The trades have been awesome for me, I know the trades are still an awesome career choice... I guess the times have changed.
  7. Where have all the techs gone? I have added 2...

    Where have all the techs gone? I have added 2 service techs in the last 6 months and with the department growing I need another but the pool of qualified applicants just is not there. We have tried...
  8. Commercial Service Tech Needed- Boston Metro

    Hi Fellas,

    One of New Englandís largest Mechanical Contractors is seeking a seasoned commercial service tech to join our growing HVAC Service Department. Must be experienced and currently working...
  9. Replies
    12
    Views
    959

    Might want to save a copy of the station...

    Might want to save a copy of the station *unedited* too... just in case "something bad" happens!
  10. I'll have 2 available if you can wait a couple...

    I'll have 2 available if you can wait a couple weeks.
  11. Thread: FX40 stuff

    by hvac_czar
    Replies
    12
    Views
    1,055

    So, for someone still somewhat new to the FX40...

    So, for someone still somewhat new to the FX40 (and JACE), could you give me a short tutorial? I have a line powered rs232 to rs485 converter. The N2 cable I'm confident I can figure out, the serial...
  12. Replies
    22
    Views
    2,831

    That's odd, the only thing mine brought to the...

    That's odd, the only thing mine brought to the yard was the neighbors St. Bernard... and he left something behind! :-)
  13. Replies
    22
    Views
    2,831

    Good luck with that! :-) The USB...

    Good luck with that! :-)




    The USB version works mint, I wish LonSpec would work with it, watch out for port conflicts between Rover and Lonspec if you have both installed.
  14. Thread: FX40 stuff

    by hvac_czar
    Replies
    12
    Views
    1,055

    Yeah, that's what I'm getting... RTU had LonMark...

    Yeah, that's what I'm getting... RTU had LonMark stickers all over it, opened it up and found BacNet card installed! :-(
  15. Thread: FX40 stuff

    by hvac_czar
    Replies
    12
    Views
    1,055

    Sorry, meant Workbench! Opened remote...

    Sorry, meant Workbench!

    Opened remote station... uploaded station... all controllers came online... opened controller and got "graphics file not found" error.
  16. Thread: FX40 stuff

    by hvac_czar
    Replies
    12
    Views
    1,055

    FX40 stuff

    Hey fellas,

    A question and an odd occurance while uploading an FX40... Is there any way to bring in a BacNet and an N2 bus into the same FX40? And, why do my graphics files not upload to the FX40...
  17. Replies
    28
    Views
    2,056

    How is the evaporator coil? Clean? Rated airflow?...

    How is the evaporator coil? Clean? Rated airflow? This is the first rule, before you even think about grabbing the refrigerant jug.

    Never lose the quest for knowlege, it is missing in most folks...
  18. Thread: FX Builder

    by hvac_czar
    Replies
    13
    Views
    2,551

    It is also worthwhile to note that you may be...

    It is also worthwhile to note that you may be able to write an app in FX Builder, specific to your job, using an FX07 that to use an FX Builder Express app would take an FX16 AND an FX15! This is JCs...
  19. Thread: FX Builder

    by hvac_czar
    Replies
    13
    Views
    2,551

    The Builder Express standard apps are as close to...

    The Builder Express standard apps are as close to HVAC Pro as you will get. For writing your own Builder apps you should really start off with the class offered by JC... Unless you are way above the...
  20. Replies
    14
    Views
    2,072

    How many would you like? I have 2 or 3 in fair...

    How many would you like?

    I have 2 or 3 in fair used condition.

    PM with reasonable offer.
  21. Replies
    4
    Views
    660

    OCC/UNOCC scheduler? I looked at the app and...

    OCC/UNOCC scheduler?

    I looked at the app and don't see anything other than that used to calculate common setpoint.
  22. Replies
    2
    Views
    502

    My understanding is that you would set up the...

    My understanding is that you would set up the interval between emails until the alarm is acknowleged, the directory sets the time between escalations of emails... ie, if you don't respond, how long...
  23. Replies
    10
    Views
    2,357

    Try registering it online using the exact same...

    Try registering it online using the exact same owner info you used to activate it the first time... I have successfully reinstalled Rover on the same machine it was originally installed on and...
  24. Replies
    5
    Views
    1,147

    http://www.emstec.com/class_description.php?id=113...

    http://www.emstec.com/class_description.php?id=113

    Google is your friend...
  25. Replies
    5
    Views
    1,088

    When I see a sequence like that it is generally...

    When I see a sequence like that it is generally for freeze protection... Before you modify anything, try to get inside the programmers head and don't eliminate a part of the sequence that in the end...
  26. Thread: Jci N30

    by hvac_czar
    Replies
    27
    Views
    3,655

    4D's... All the n30 docs are still available...

    4D's...

    All the n30 docs are still available on the JC website...

    Do a search for "N30" on this page: http://cgproducts.johnsoncontrols.com/default.aspx?main.aspx&2

    I've got a site down...
  27. Replies
    27
    Views
    4,521

    I believe they monitor the flue via combustion...

    I believe they monitor the flue via combustion chamber pressure, if flue, or HX is restricted you get the fault. Think of that dual switch proving you have minimum air and it will fault if you have...
  28. Replies
    13
    Views
    1,072

    I'm glad it's done, perhaps now the job can get...

    I'm glad it's done, perhaps now the job can get turned over on time.

    BTW, I've never seen any Red Sox tickets and don't want to... Makes it easier to do my job when I don't owe anyone any favors. ...
  29. Replies
    7
    Views
    726

    This is another mystery then on this job. :-) ...

    This is another mystery then on this job. :-)

    I am trying to learn a bunch of different systems so everyones input is appreciated.

    How slow is the slow flash? This controller is flashing about...
  30. Replies
    13
    Views
    1,072

    Thanks for the input guys... I take the FX40...

    Thanks for the input guys...

    I take the FX40 class starting second week of March... It will have to wait till I know my way around in there! :-)

    I had read the Rover users guide after my last...
  31. Replies
    27
    Views
    4,521

    Any green deposits anywhere within the combustion...

    Any green deposits anywhere within the combustion chamber? On tubes, refractory or burners? Every time I've seen this type of damage there has been some degree of condensation on the tubes due to low...
  32. Replies
    13
    Views
    1,072

    LOL, I'm coming around to that conclusion too! ...

    LOL, I'm coming around to that conclusion too!

    Thanks for the assist!
  33. Replies
    13
    Views
    1,072

    Hey Dapper, I need active mode to set bindings...

    Hey Dapper,

    I need active mode to set bindings to share one zone sensor between 2 UV's...

    I have version 6.00, I am using the supplied USB to Lon adapter.

    The controls contractor brought the...
  34. Replies
    13
    Views
    1,072

    Rover active mode

    Folks,

    When running Rover on comm 5 in active mode I have zn520 boards that drop out intermittantly and Rover locks up, never allowing active mode to run... All devices show up and stay connected...
  35. Replies
    7
    Views
    726

    Hi ctrlguy, Thanks for the reply... I tried...

    Hi ctrlguy,

    Thanks for the reply... I tried recommissioning but no comm. The controller is not functioning, are the led functions only applicable in stand alone mode? None of the other 40...
  36. Replies
    7
    Views
    726

    HW W7762B1027 HYD controller

    Fellas,

    I have a job with the above controller, no comm to XL15A supervisory controller, NIC is correct, led on board has slow flash, bus is good... what does slow flash mean, no other controller...
  37. Replies
    22
    Views
    1,652

    Not lucky... You can get anything from Trane if...

    Not lucky... You can get anything from Trane if you know who and how to ask. I've got Rover too... the full version...
  38. Replies
    3
    Views
    941

    Thanks for the assists fellas... I had tried wink...

    Thanks for the assists fellas... I had tried wink and the service pin with no luck, picked up new board this AM and installed it just now... working great. I also talked the Trane local office into...
  39. Replies
    3
    Views
    941

    Trane zn520 issues...

    Fellas,

    A couple questions re: this board.

    In Rover I can communicate with the bus fine but one particular zn520 does not show up even connected to it's zone sensor. No heartbeat on board...
  40. Replies
    7
    Views
    2,391

    I broke down and bought a new card... "official"...

    I broke down and bought a new card... "official" answer from Honeywell is that a driver for USB to LON adapter will be out "soon"!!!!

    Life goes on!
  41. Thread: Bad board?

    by hvac_czar
    Replies
    26
    Views
    5,459

    Your answer is in the date on the photo! 10-31

    Your answer is in the date on the photo! 10-31
  42. Replies
    10
    Views
    746

    The price difference likely has alot more to do...

    The price difference likely has alot more to do with the contractor than the equipment... Go with the guy who makes you most comfortable in terms of answering your questions and addressing your...
  43. Replies
    7
    Views
    2,391

    OK, so I loaded OpenLDV and I have a PCCLON1 port...

    OK, so I loaded OpenLDV and I have a PCCLON1 port available under Network interface type PCLTA in LonSpec... Is this a go? In LonSpec there is no network interface that matches my USB to LON adapter...
  44. Replies
    7
    Views
    2,391

    Lost LON card

    I went to a site today to work on a Honeywell Excel system and my LON card was gone from my bag... :-( I still have the dongle but it's of little use without the PCMCIA card. Is this the only...
  45. Replies
    10
    Views
    951

    Thanks for the assists guys... TX, I'll get the...

    Thanks for the assists guys... TX, I'll get the SB from Trane tomorrow and see if it applies. Anything to add jayguy? You seem to be the go-to guy for Trane stuff... :-)
  46. Replies
    10
    Views
    951

    Reliatel weirdness

    I've got a 5 ton Precedent with Reliatel controls locking out intermittantly... On the ignition board LED1 I get a one code that means "comm loss". Prior to me looking at it the main board and...
  47. Replies
    0
    Views
    547

    Carrier CCN... Parker VVT

    Hey folks,

    I've listed a new Carrier CCN I/O module for sale on E-bay #250200519405

    I've also got a huge load of 1st gen. Parker stuff coming up... e-mail in profile. Multiple master stats,...
  48. Replies
    0
    Views
    575

    Carrier CCN... Parker VVT

    Please see my post in the junkyard RE: CCN and Parker stuff for sale!
  49. Replies
    2
    Views
    1,227

    Thanks Dapper... I had DL the schematics from...

    Thanks Dapper... I had DL the schematics from Titus and there was no mention of needing them... 2 thoughts had come to my mind: either to protect the sensor from spikes or to slow the box down ie:...
  50. Replies
    2
    Views
    1,227

    Titus TA1 and KMC CTE 5103

    I'm retrofitting new VAV boxes into a space that has existing Titus controllers and KMC zone sensors... Many of the zone sensors have resistors wired into the R1 and 12v terminals. The new boxes and...
Results 1 to 50 of 943
Page 1 of 19 1 2 3 4