Search:

Type: Posts; User: rselby

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    12
    Views
    2,359

    That is a fact, he didn't do his job. A stick...

    That is a fact, he didn't do his job. A stick per joint, that's going to be expensive in more ways than one. I sure hope he didn't have any leaks? ;-)

    Sent from my SCH-I535 using Tapatalk now...
  2. Replies
    12
    Views
    2,359

    I don't think brazing without N2 would cause that...

    I don't think brazing without N2 would cause that much build up, that looks like a major oil problem. N2 is always a great protocol but how many units have been burned in without driers or N2? And...
  3. Replies
    25
    Views
    10,522

    I just found an add on app for Evernote that lets...

    I just found an add on app for Evernote that lets you create your own forms, http://kustomnote.com
    I made my own equipment list, belt list, refrigerant type and system charge, M# and S#. I have ...
  4. Replies
    25
    Views
    10,522

    Handy apps for HVAC Techs

    HVAC Buddy is general knowledge you should have in your head if you've been in the field for any length of time. I guess it could be useful for some, I use it occasionally, a note pad, calculator and...
  5. Replies
    8
    Views
    963

    Yeah I thought about relocating them. I have one...

    Yeah I thought about relocating them. I have one machine that is about 30' from the dough room, I have to go through 2 doors to get to it and I've only had to clean it once in 6 months.
  6. Replies
    8
    Views
    963

    That's what I'm trying to avoid, it's not cost...

    That's what I'm trying to avoid, it's not cost effective for my customer but it's very profitable for me:yes:
  7. Replies
    8
    Views
    963

    Yeast is making a mess in my Ice Machines.

    I have several Pizza Restaurants that have Ice makers with in 10 feet of the dough room. The inside of the machines are growing a white paste (water snot) at an incredible rate and plugging up the...
  8. You can't correctly sub cool with a mixture of...

    You can't correctly sub cool with a mixture of liquid and vapor, you must have a solid column of liquid all the way to the TXV.
    Gas it up and let it shut down while you monitor system pressures,...
  9. Replies
    3,469
    Views
    152,123

    Two 9mm pistols.

    Two 9mm pistols.
  10. Replies
    6
    Views
    1,069

    I quoted the job using a Coleman furnace, I don't...

    I quoted the job using a Coleman furnace, I don't think they liked the price but I'd rather be safe than sorry.


    Sent from my SCH-I535 using Tapatalk 2
  11. Thread: Simed up Hoshi

    by rselby
    Replies
    9
    Views
    1,938

    Ok, well that's typical. I take care of 9 pizza...

    Ok, well that's typical. I take care of 9 pizza places and I've seen some similar looking things. In most cases, unless I'm the guy taking care of the PM work, the pizza restaurants don't do any...
  12. Replies
    3,469
    Views
    152,123

    Your not really looking for answers so much are...

    Your not really looking for answers so much are you? I think perhaps your looking to argue. Consider the Hoover dam as an example.

    Sent from my SCH-I535 using Tapatalk 2
  13. Thread: Simed up Hoshi

    by rselby
    Replies
    9
    Views
    1,938

    That is some nasty looking black algae, is this...

    That is some nasty looking black algae, is this machine by a bakery or around yeast? I'm curious to see what the hoses and the water distributors look like.

    Sent from my SCH-I535 using Tapatalk 2
  14. Replies
    3,469
    Views
    152,123

    Your welcome. I apologize I got a little windy...

    Your welcome. I apologize I got a little windy on that one.
  15. Replies
    3,469
    Views
    152,123

    Bans and regulatory laws only slow down an honest...

    Bans and regulatory laws only slow down an honest man. The old add age still applies, if guns and bullets are banned only criminals will use guns.
    We certainly don't blame cars when a drunk...
  16. Replies
    3,469
    Views
    152,123

    Very simply put, for hunting, home protection and...

    Very simply put, for hunting, home protection and thirdly it's my second amendment right completely spelled out in the Constitution.

    Sent from my SCH-I535 using Tapatalk 2
  17. Replies
    6
    Views
    1,069

    Mobile Home Furnace question.

    I've tried to locate parts for an old Magic Chef furnace to convert it to LP gas. After looking the unit over I figured it's better to replace it.
    I live in California (The state of entitlement),...
  18. BTW, your part number is correct.

    BTW, your part number is correct.
  19. Yes, you're both correct about the I/R eyes. I...

    Yes, you're both correct about the I/R eyes. I called Scotsman today and started to tell the tech support guy about the Manitowoc ice bin and he finished my sentence saying well you're going to...
  20. Replies
    12
    Views
    2,195

    Got it, you're making a small receiver out of...

    Got it, you're making a small receiver out of the drier by tilting it down. The old Hussmann s/c freezers had a hollowed out Sporlan drier mounted vertically and a LLFD just down stream. Your...
  21. Replies
    12
    Views
    2,195

    That's a great idea, I've never considered...

    That's a great idea, I've never considered swapping the cap tube with a TXV, it does makes sense. Do you add a receiver or just make sure you have a liquid seal @ the TXV?

    BTW, I was just sharing...
  22. Ok, I'll check it out on Monday, Thank you.

    Ok, I'll check it out on Monday, Thank you.
  23. What is the procedure to check the setup?

    What is the procedure to check the setup?
  24. Replies
    12
    Views
    2,195

    You don't need to get an Embracco, a Copeland or...

    You don't need to get an Embracco, a Copeland or Tecumseh will work too. More than likely it's a 1/3 HP CSIR compressor. I would probably use R-134A, but in reality MP 39 will work too, so that's...
  25. Scotsman - Manitowoc mismatch ice overflow problem.

    I have a Scotsman CME506AS-1F ice machine on a Manitowoc B-570 ice bin. Ice is overflowing from the bin when the bin door is opened. I've already confirmed the bin sensor works correctly, the ice...
  26. Replies
    35
    Views
    3,569

    I agree with your statement, superheat at the...

    I agree with your statement, superheat at the evap coil would have been some handy information to know.
  27. Thread: Poor Brazing

    by rselby
    Replies
    13
    Views
    3,583

    Looks like pigeon crap, LOL! I'm guessing, but I...

    Looks like pigeon crap, LOL! I'm guessing, but I think they (original tech) tried to braze this with some pressure in the system.
    I'll bet you didn't have any problems closing that up? Good call...
  28. Replies
    18
    Views
    3,397

    You must have an enemy out there or the...

    You must have an enemy out there or the competition's getting fierce these days. What a bummer!
  29. Replies
    35
    Views
    3,569

    What was the ambient temperature? He didn't...

    What was the ambient temperature? He didn't calculate superheat, which would have been really nice to know. Shooting from the hip, yes you have a leak and a 7* split (with missing information)...
  30. Replies
    4
    Views
    1,361

    Intuit, isn't that the company that makes Quick...

    Intuit, isn't that the company that makes Quick Books? The card reader I saw was from Square App, they charge you 10 bucks for the reader and give it back after your first transaction, the app is...
  31. Replies
    4
    Views
    1,361

    iPad 2 for invoicing and POS?????

    Got a quick question for all of the residential/commercial techs. Are any of you using an iPad 2 to for invoicing and credit card payments?
    I saw a very interesting article about this and thought...
  32. Thread: Just For Men

    by rselby
    Replies
    25
    Views
    1,861

    Let it go gray, it's just who you are and that...

    Let it go gray, it's just who you are and that should be good enough for anyone.
    I have a family member who's been using that crap for several years, doesn't do much good when your face looks 50...
  33. Replies
    41
    Views
    11,524

    How cool is that? Talk about going the extra...

    How cool is that? Talk about going the extra mile!
  34. Replies
    17
    Views
    8,866

    I chuckled a bit when I first heard about a local...

    I chuckled a bit when I first heard about a local company promoting this method and charging the customer a little over 1k to do it. My question to them was do you change the oil? "Ah, no we...
  35. Replies
    41
    Views
    11,524

    Had one similar to this, customer had 15 cats in...

    Had one similar to this, customer had 15 cats in a 2 bedroom condo. The R/A was under the closet door at floor level with "no" filter.
  36. Thread: Testo 550

    by rselby
    Replies
    183
    Views
    34,556

    I'm glad I looked before leaping.

    I have avoided making the purchase and I'm glad I haven't spent the cash on these. Maybe I'm missing something but can't you do the same thing with a good quality thermometer, calibrated gauges and...
  37. Replies
    170
    Views
    59,330

    H10 vs Tek Mate w/410a

    @ LT 1 FUN,

    I haven't done much work with R-410a..... yet! That's good information to know about the Tek-Mate vs the H10 corded. I'm usually in Supermarkets or Packing Sheds now. I was doing...
  38. Replies
    170
    Views
    59,330

    H10PM

    I had a larger battery in my old H10PM and used a higher capacity charger as well. I know the battery came from "Battery Bill" and I think the charger came from Bacharach. It gives you about 30...
  39. Replies
    170
    Views
    59,330

    Which H10 are you using, the corded or the...

    Which H10 are you using, the corded or the battery operated?

    Regards,

    Richard
  40. Replies
    170
    Views
    59,330

    I agree

    Hi JP,

    I concur about the H-10, but I'll have to mention it's really a pain in the butt to use the corded unit in a Supermarket. The H10PM battery operated model generally runs out of juice way...
  41. Replies
    12
    Views
    1,459

    Hussmann Thermoficient Food Store Refrigeration Package

    I work on these regularly, the old push pull oil system was wonderful while it was running however if one machine goes down it doesn't take long for things to get complicated. The newer systems use...
  42. Replies
    16
    Views
    3,114

    Danfoss vs Sporlan

    Ok, right off the start I'm a big fan of Sporlan components.
    Here is a direct question for everyone who feels the same as I do,
    (Have you ever replaced a Sporlan TXV with a Danfoss TXV?) If you...
  43. Replies
    5
    Views
    1,039

    I concur, I also like the the H10PM, the only...

    I concur, I also like the the H10PM, the only reason I don't use it as much as I used to is because of the terrible battery life.
    Here is what I usually do, I'll use the D-Tek to find my leak area...
  44. Replies
    33
    Views
    1,686

    This is great back to the basics information,...

    This is great back to the basics information, FUBAR= Frequently Unused But Always Reliable. Thank you for putting that up icehouse.;)
  45. Replies
    33
    Views
    1,686

    Overcharged possibly? I'd weigh in 1/2 the...

    Overcharged possibly? I'd weigh in 1/2 the charge fire it off and watch the pressures as I slowly added gas from that point.
    Has this compressor been changed out before?
    You've received some...
  46. Replies
    7
    Views
    800

    Use a Sporlan C032-CAP-T Catch-All. Once you do,...

    Use a Sporlan C032-CAP-T Catch-All. Once you do, you'll never go back. ;)[/QUOTE]

    10-4 to that!
  47. Replies
    2
    Views
    461

    Good call on the oil change, that's the key...

    Good call on the oil change, that's the key especially if it's POE oil. The reality is you may need to do more than 1 oil change... even with a good evacuation @ 500 microns. It really bites if...
  48. Replies
    5
    Views
    1,039

    Evaporator leaks/ Ultrasonic Leak Detectors?

    I'm a fin cuttin', pass condemning, weld it off, by passing crazy man when it comes to coil leaks. Let met qualify myself by saying I look the situation over intently before making a decision to...
  49. Replies
    5
    Views
    1,670

    I've hooked my meter up to the timing circuit and...

    I've hooked my meter up to the timing circuit and watched it read voltage and the light never came on. I don't care for Sentronic oil failure controls too much (new or old). I've changed out dozens...
  50. Replies
    2
    Views
    372

    Looking for 36' LT Coffin cases

    I'm looking for a reputable company that sells good used equipment. I'd like to find a 36' line up of Low Temp coffin cases that are 5-10 years old in decent
    condition at a reasonable price. ...
Results 1 to 50 of 85
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event