  1. Glad to know someone else was thinking the same...

    Glad to know someone else was thinking the same thing. And thanks; HS teacher used to say it.


    Life is 10% what happens to you and 90% how you react.
  2. Did you check all the safety limits? There may be...

    Did you check all the safety limits? There may be one on the blower that's open, causing the problem. You said the furnace lights though? Only a two year tech here. ;)


    Life is 10% what happens...
  3. Replies
    12
    Views
    430

    I saw it in a small catalog at UR. Said voice...

    I saw it in a small catalog at UR. Said voice command but then the product info said nothing about that feature. Counter guy said, "it's too f***ing hot!" or "damn, it's cold!" is how it works...
  4. Replies
    22
    Views
    861

    Phosgene is the result of heated refrigerant, and...

    Phosgene is the result of heated refrigerant, and you wouldn't be brazing with it in the lines. I'm not sure then what the other guy was talking about. If anything, you just need to be aware of oil...
  5. Replies
    94
    Views
    2,803

    Last I checked electricity was color blind. ;) ...

    Last I checked electricity was color blind. ;)


    Life is 10% what happens to you and 90% how you react.
  6. Replies
    26
    Views
    1,231

    Thanks! I'll keep that in mind.

    Thanks! I'll keep that in mind.
  7. Replies
    26
    Views
    1,231

    I've never seen this formula before. Could you...

    I've never seen this formula before. Could you explain the rationale for it?
  8. X2 simple math will tell you that. Cylinder...

    X2 simple math will tell you that.
    Cylinder volume = pi * r^2 * height
  9. Replies
    25
    Views
    1,070

    I didn't see it in any pictures, but was the...

    I didn't see it in any pictures, but was the float switch wired in correctly?
  10. Replies
    32
    Views
    1,312

    Stupid? Question about hoses

    My 410a gages have ball valve, but my 22 set is low loss. I like both.
    I too was under the impression that some kind of low loss hoses were required for service to lessen loss. Loosing all that...
  11. Replies
    65
    Views
    2,870

    Restriction at the distributor would be my guess....

    Restriction at the distributor would be my guess. Definitely a restriction though if it's freezing at that point.
  12. Replies
    63
    Views
    2,413

    I have two sets, one for 22 and another for 410a....

    I have two sets, one for 22 and another for 410a. That way I know I won't mix refrigerants.

    One thing an instructor told me about purging though is that if you purge and connect, the air in your...
  13. Replies
    34
    Views
    1,956

    When I used to take music lessons, my teacher...

    When I used to take music lessons, my teacher would always say, "Practice doesn't make perfect, perfect practice makes perfect." Meaning if you do something wrong repetitively, you'll keep doing it...
  14. Replies
    22
    Views
    1,472

    If you're using a SH calculator, you need outdoor...

    If you're using a SH calculator, you need outdoor ambient and indoor wet bulb to properly charge via SH. Your target might be 10 in 90 degree weather, but might only be 6 if it's 70 outside and dry...
  15. Replies
    22
    Views
    1,472

    He's talking about doing PMs on units, not...

    He's talking about doing PMs on units, not running ac for cooling comfort.
  16. Replies
    15
    Views
    719

    Frosted Coil

    I'd say outdoor temp. Forty-five degrees outside is in no way a good indicator of cooling. If anything, your saturation temp was around 70 outside, so having such a low temp there would surely have...
  17. Replies
    21
    Views
    755

    If the outdoor is also 2.5, you could run into...

    If the outdoor is also 2.5, you could run into problems just changing the AH. Too much refer in the evaporator. The EPR and HGBP would help mimic the proper BTU rating.
  18. Replies
    9
    Views
    495

    I'd use the piston that came with the condenser....

    I'd use the piston that came with the condenser. Even on new installs the evaporator piston doesn't match what came with the condenser all the time.
  19. Replies
    7
    Views
    735

    http://www.buildingcenter.org/trane Might be...

    http://www.buildingcenter.org/trane

    Might be helpful, but I couldn't find a similar serial example.
  20. Replies
    7
    Views
    580

    What's the btu rating on the AC?

    What's the btu rating on the AC?
  21. Replies
    51
    Views
    3,257

    X2. Charging by sight glass can get you in...

    X2. Charging by sight glass can get you in trouble. Stick with SH/SC charging.
  22. Replies
    16
    Views
    818

    Hmm, only two posts too. Smells like... DIY.

    Hmm, only two posts too. Smells like... DIY.
  23. I disagree. Like others, I say it helps the motor...

    I disagree. Like others, I say it helps the motor run efficiently and that it puts the electricity in better phase alignment in addition to the boost it provides to the motor.
  24. Replies
    17
    Views
    742

    If the reversing valve is energized in cooling,...

    If the reversing valve is energized in cooling, you should get 24v from O to common or 0v from R to O. The AH provides the 24v for the outdoor unit to run after all.
  25. Replies
    10
    Views
    665

    H310 in serial means it was made 10th week of...

    H310 in serial means it was made 10th week of 1983. So it's about to turn 31!