  1. Thread: Fancy meter

    by Core_d
    Replies
    23
    Views
    1,309

    No they dont. Not unless its more than 600v ;)

    No they dont. Not unless its more than 600v ;)
  2. Replies
    36
    Views
    1,096

    Sounds like quite a glide between the two. Kinda...

    Sounds like quite a glide between the two. Kinda like speed-balling.
  3. Replies
    36
    Views
    1,096

    Lotta good laughs on htalk tonight lol.

    Lotta good laughs on htalk tonight lol.
  4. Thread: Fancy meter

    by Core_d
    Replies
    23
    Views
    1,309

    Best post ever lol

    Best post ever lol
  5. Replies
    18
    Views
    1,211

    I had a similar experience shipped me a red knob...

    I had a similar experience shipped me a red knob for free. Replied and sent on a Sunday. Not even close to under warranty.
  6. Thread: moles

    by Core_d
    Replies
    26
    Views
    641

    Use your ultra sonic leak detector to find em and...

    Use your ultra sonic leak detector to find em and a frog gig to pull em up. Instructor at a lennox class had a story about it. Swears it works
  7. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    The indoor coil does not have a service port...

    The indoor coil does not have a service port sticking out unfortunately. And you could very well be right that it wont frost up under a better load. Ide like to go back and investigate further.
    ...
  8. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Thank you thats what ive been saying all along....

    Thank you thats what ive been saying all along. This thread has been a little frustrating for me but if im wrong so be it, wouldn't be the first time. Im still pretty certain the drop in pressure is...
  9. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Temp will drop with pressure thats 101

    Temp will drop with pressure thats 101
  10. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Runs good

    Yeah i agree bigtime
  11. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Dont mean to sound like a Bhole but come on

    Dont mean to sound like a Bhole but come on
  12. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    I humbley partake in this site all the time. My...

    I humbley partake in this site all the time. My diagnosis is my educated opinionion if im wrong ill deal with that. If its an airflow issue why is my coil not frosting? It should get warmer as it...
  13. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Runs good

    Its a fact the line is too small per trane
  14. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    I already stated temps at the suction line...

    I already stated temps at the suction line leaving the coil. Maybe im not as experienced as some techs here but i feel like im under attack.

    Everyone is pointing that im wrong but havent had a...
  15. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Oh yeah? If the super heat and pressure is good...

    Oh yeah? If the super heat and pressure is good at the coil did i make a big deal about nothing?
  16. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Do you guys work in the field or is your soul...

    Do you guys work in the field or is your soul purpose busting my balls? Lol. IT AINT RIGHT.
  17. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Yes from indoor coil to outdoor coil.

    Yes from indoor coil to outdoor coil.
  18. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Whats the issue then is a 9* drop across suction...

    Whats the issue then is a 9* drop across suction cool.
  19. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Yeah indoor was around 65 a little higher. Still...

    Yeah indoor was around 65 a little higher. Still that kinda drop is a no go. Hardworker already confirmed the suction is too small. Whys it so hard to fathom?
  20. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Thats beyond my skillset all i lnow is its wrong....

    Thats beyond my skillset all i lnow is its wrong. Ive never had any training on tinkering with improperly sized systems.
  21. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Ide guess i had little to no superheat exiting...

    Ide guess i had little to no superheat exiting the indoor coil
  22. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Please keep in mind the superheat and pressures...

    Please keep in mind the superheat and pressures at the outdoor unit does not really mean much. As the pressure is dropping along the way.
  23. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Does that head look high? Not sure wat your...

    Does that head look high? Not sure wat your getting at? It is a piston system.

    You figure my od coil is suffering from restricted airflow or wat? You kinda lost me bub?
  24. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Out side air? Round 75 return air? Round 65. ...

    Out side air? Round 75 return air? Round 65. What is the previous question i missed?
  25. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    48 suc 173 head 16sc 4 sh

    48 suc 173 head 16sc 4 sh
  26. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Piston

    Piston
  27. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    575781 This help any?

    575781

    This help any?
  28. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Did not look at discharge superheat. Those...

    Did not look at discharge superheat. Those numbers would not mean a great deal to me if i did have them.
  29. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    As far as i can see i have three had 90s in line...

    As far as i can see i have three had 90s in line as well. What else could it be?
  30. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Im confident in my diagnosis. And your right...

    Im confident in my diagnosis. And your right they really dont care. The pressure drop across the suction line is obvious. No visible kinks in the or anything.

    What should my suction line...
  31. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Runs good

    5 ton, and i couldnt really care less what the reduction looks like. Its the fact thats its not installed right.
  32. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Like what?

    Like what?
  33. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Runs good

    Well its only problem to me i guess. this was new customer pm call. She had showed me a couple of invoices from other company's pm's. Only problem i can advise of is a capacity loss at added...
  34. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Runs good

    Yes indoor fan is running, linsets around 70 ft im guessing. Suction line at evap was38* line outside 29* and 48 psi. Not sure the actual pressure at the indoor coil.

    I was told its worked fine...
  35. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Lol good guess.

    Lol good guess.
  36. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Or the out door suction line:)

    Or the out door suction line:)
  37. Thread: Runs good

    by Core_d
    Replies
    77
    Views
    3,130

    Runs good

    Not a bit of frost on the indoor coil. Care to guess why? 575601575611
  38. Replies
    15
    Views
    1,628

    Those hard turns are for air mixing purposes.

    Those hard turns are for air mixing purposes.
  39. Replies
    19
    Views
    965

    Whats the temp drop? Try turning the blower up a...

    Whats the temp drop? Try turning the blower up a little bit.
  40. Replies
    15
    Views
    1,628

    Looks cool to me.

    Looks cool to me.
  41. Replies
    11
    Views
    270

    So it wont shut off?

    So it wont shut off?
  42. Replies
    17
    Views
    890

    Thats where i ended up going after a blank stair...

    Thats where i ended up going after a blank stair from rsc. Johnstone sent me on my way as well. Had to get one static tip at one place and one at another. As they each had one in stock.
  43. Copper to copper no clean no flux. Copper to...

    Copper to copper no clean no flux.

    Copper to steel clean and flux
  44. Replies
    35
    Views
    1,452

    I thought the issue was the oil foaming up when...

    I thought the issue was the oil foaming up when saturated with water. Not decomposing?
  45. Replies
    35
    Views
    1,452

    Yea its junk dude.

    Yea its junk dude.
  46. Replies
    81
    Views
    1,640

    Poll: Yes

    Yes
  47. Replies
    10
    Views
    361

    Thats the real deal

    Thats the real deal
  48. Replies
    10
    Views
    361

    Also seen this ye old gas valve a while back on...

    Also seen this ye old gas valve a while back on an oven made in ohio. Valve was made in Germany 570541
  49. Replies
    10
    Views
    361

    Now that i think about it, it did have a note...

    Now that i think about it, it did have a note about keeping it level.
  50. Replies
    10
    Views
    361

    Ide let it go at a very reasonable price;) bs

    Ide let it go at a very reasonable price;) bs