Search:

Type: Posts; User: Todd Whaley

Page 1 of 14 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    3
    Views
    232

    Ss2 seems to be our go to. The only time I see...

    Ss2 seems to be our go to. The only time I see problems is when installers put them in improperly.
  2. I had to contact manufacturer to see the ohm...

    I had to contact manufacturer to see the ohm value should be to the corresponding oat. Lennox thing....
  3. get your post count up and apply for pros status....

    get your post count up and apply for pros status. Cannot give detailed technical support out in open forums.
  4. Are you going to feed 24v to the 700?

    Are you going to feed 24v to the 700?
  5. Usually find them where they are zip tied to the...

    Usually find them where they are zip tied to the copper. Found one where guys putting up a radient barrier pierced the t-stat wires. I had to remove alot of it.
  6. Replies
    8
    Views
    200

    Tighten everything.

    Tighten everything.
  7. Replies
    15
    Views
    418

    Well its laryngitis. First doc gave me amox to...

    Well its laryngitis. First doc gave me amox to treat a virus.....nice. second doc said, "we are gonna give you strong cough syrup since hacking your guts up wont help inflammation". They took...
  8. Replies
    15
    Views
    418

    Required PPE yes. In truck, No. I have a loaner...

    Required PPE yes. In truck, No. I have a loaner truck right now, so kinda my fault. I did wear during duct installs and cleans.
  9. Replies
    15
    Views
    418

    Web MD has the audacity to list Anthrax as the #2...

    Web MD has the audacity to list Anthrax as the #2 possible cause.... HA!
  10. Replies
    39
    Views
    1,370

    Bats on the id coil. Decomposed. HO said there...

    Bats on the id coil. Decomposed. HO said there was an odd smell over the summer. I thought it was insulation when I retrieved it. Ugh.
  11. Feel you pain with Lennox.

    Feel you pain with Lennox.
  12. Replies
    15
    Views
    418

    strange illness

    Well I started with a severe cough leading to inflammation of the vocal cords. No other symptoms. Now a week later cough persists, very little chest congestion, low grade fever, fatigue, body...
  13. Replies
    16
    Views
    684

    No not aluminum. Over the summer I ran many...

    No not aluminum. Over the summer I ran many calls 1st year on rheem packs.
  14. Replies
    17
    Views
    2,444

    Had a carrier pack yesterday with Swiss cheese...

    Had a carrier pack yesterday with Swiss cheese HX. Priced repairs, out of warranty, HO wanted me to weld it up. 99 pack, recommended replacement, have not heard back. Would like to know what he...
  15. Replies
    6
    Views
    1,345

    Mighty putty.

    Mighty putty.
  16. Replies
    17
    Views
    2,444

    Bypassed door switch. Classic. I actually raid...

    Bypassed door switch. Classic. I actually raid the scrap pile for those things just in case they are missing, but they usually turn up near the unit. Underneath....
  17. Replies
    24
    Views
    1,946

    Have a lady with a Lennox pure air kit who has to...

    Have a lady with a Lennox pure air kit who has to change it every six months. Suck it up and smoke outside. Too expensive to change that frequently.
  18. Replies
    16
    Views
    684

    leakers+txv+x13=ugh :gah:

    leakers+txv+x13=ugh :gah:
  19. Replies
    53
    Views
    3,267

    Auto changover on a second floor breezeway. Gas...

    Auto changover on a second floor breezeway. Gas logs. You know where this is going
  20. Replies
    53
    Views
    3,267

    yup. done that.

    yup. done that.
  21. Replies
    30
    Views
    1,664

    It's one of those units that defy logic and...

    It's one of those units that defy logic and reason. More the reason to keep her running. Is that some kind of Carrier?
  22. Replies
    4
    Views
    269

    Pipe clamp thermo

    Any suggestions of a DURABLE pipe clamp thermocouple? Gonna get what i pay for? Plastic jaws either snap at the spring, or wires become loose. I'm sure this topic has been beaten to death :gah:
  23. Replies
    6
    Views
    723

    Nice to see that particular unit not pinned to a...

    Nice to see that particular unit not pinned to a house for a change.
  24. Recommend a uv light to help keep the snakes to a...

    Recommend a uv light to help keep the snakes to a minimum, hah
  25. Replies
    3
    Views
    416

    I see alot of cases where throwing VB, and...

    I see alot of cases where throwing VB, and dehumidifiers "just for the spiff of it" is believed to be the cure all. I ask is this a little residual moisture, or is this a poor drainage/grading issue...
  26. Replies
    3
    Views
    416

    Spray foam crawl

    My last call of the night was to get an Aprilaire de-hum up and running. The crawl had been spray foamed in place of fiberglass batting. The vapor barrier was sparse, and the vents were opened. ...
  27. What was the heat and cool supply vent about? ...

    What was the heat and cool supply vent about? Was it a damper he was talking about? Or was he referring to closing supply vents?
  28. Replies
    9
    Views
    689

    Sorry correction, this is an LP setup. Had 6.58...

    Sorry correction, this is an LP setup. Had 6.58 iwc on low running 39960 btuh of 54000. After reading the manufacturers nomenclature i found this=
    Units fueled by LP/propane gas are rated for...
  29. Replies
    9
    Views
    689

    Outlet 1.83 iwc on low fire.

    Outlet 1.83 iwc on low fire.
  30. Replies
    40
    Views
    2,473

    Have the fluke combo. Only complaint was the...

    Have the fluke combo. Only complaint was the temp adapter stopped working. Really like the retractable leads.
  31. Replies
    7
    Views
    447

    This was one of two returns. It was an upstairs...

    This was one of two returns. It was an upstairs 12x12..... it was a 2 ton brand new cbx25uh. Had one of those 3M 16x25x1 static killer on the other return. I told her to visit filter easy website...
  32. Replies
    7
    Views
    447

    indoor air quality is always on the back burner.

    indoor air quality is always on the back burner.
  33. Replies
    7
    Views
    447

    Dirty filter contest?

    Temporary filter 12x12 circa 2005 :eek2:515691
    HO said nobody ever asked to check the filter upstairs.
  34. Replies
    9
    Views
    689

    Oh will do. Thinking if the high fire solenoid...

    Oh will do. Thinking if the high fire solenoid is energized but not working inducer will not ramp up either. Its a 15GCSX series btw
  35. Replies
    9
    Views
    689

    Was on the phone with lennox tech support, they...

    Was on the phone with lennox tech support, they quickly told me to replace the valve and they have seen this before. Of course I did check t-stat setup, wiring, and gas pressure.
  36. Replies
    9
    Views
    689

    No fuse. Call for hi fire, voltage present at...

    No fuse. Call for hi fire, voltage present at common and hi, but no high fire.
  37. Replies
    9
    Views
    689

    gas valve issue

    Had a routine maintenance call today on a brand new Lennox gas pack. 1st stage check. Wait wait wait. No second stage. Ok install did not set up t-stat properly.... nope. Short in valve. High...
  38. Replies
    16
    Views
    876

    I changed about 10 this season. Atleast the...

    I changed about 10 this season. Atleast the module is a quickie.
  39. Replies
    28
    Views
    1,876

    What exactly is Tjernlund? Have not heard that...

    What exactly is Tjernlund? Have not heard that before. Pretty sure my board is gone. Will go through fire sequence maybe 1 out of 7 tries.
  40. Replies
    16
    Views
    1,166

    Had a cracked HX today on a Nordyne pack. And a...

    Had a cracked HX today on a Nordyne pack. And a hour on the phone with a home warranty department. Elderly couple needed help speaking to an impatient adjuster.
  41. Replies
    18
    Views
    1,315

    Is it a high crime area? Hehe

    Is it a high crime area? Hehe
  42. Replies
    28
    Views
    1,876

    Error code... flame detected when no call.

    Error code... flame detected when no call.
  43. Replies
    28
    Views
    1,876

    The one in my garage is a XL80 two stage with an...

    The one in my garage is a XL80 two stage with an intellite board. Sometines goes through sequence, but it usually runs inducer and blower in low speed. Board.
  44. Replies
    24
    Views
    3,825

    Keep it hidden.

    Keep it hidden.
  45. Replies
    45
    Views
    3,639

    I just did my fall pm on my ge's. Went in the...

    I just did my fall pm on my ge's. Went in the crawl and found I have a steam humidifier going, or just a pin hole in some quest..... hot water.... real mess now. Gonna grab 2 blower fans tomorrow...
  46. Replies
    3
    Views
    921

    Flanges were cracked..... I recommended...

    Flanges were cracked..... I recommended replacement. The ho was not aware of the problem, so he says. Its a shame... looks like its been in a flood as well as a mouse house.
  47. Replies
    39
    Views
    1,987

    So long as its not addictive.

    So long as its not addictive.
  48. Replies
    39
    Views
    1,987

    Whats the best way to limit airflow restrictions...

    Whats the best way to limit airflow restrictions in a rolled bill? Cfm/nasal passage/restrictions I.e. hair not counted unless its a wet situation.
  49. Thread: CapSizing

    by Todd Whaley
    Replies
    23
    Views
    1,112

    I have done the three cap bomb before many times....

    I have done the three cap bomb before many times. Each gets their own metal bracket.
  50. Replies
    3
    Views
    921

    Loud inducer?

    514641

    A G51MP with an inducer running RLA. It's very noisy without the pvc..... :eek2:
Results 1 to 50 of 679
Page 1 of 14 1 2 3 4