    Make sure your toggle switch is in the "remote"...

    Make sure your toggle switch is in the "remote" setting, and that the wall switch isn't faulty (take it off the wall and twist the millivolt wires together.

    It sound like its just not sparking...
  2. Replies
    16
    Views
    1,850

    I've ran into these several times. I have not...

    I've ran into these several times. I have not been able to find mercury switches new (i don't think anyone has them anymore).

    Right now Napoleon has a retro kit to switch their units to a...
  3. Replies
    6
    Views
    4,114

    Just seal the termination plate at the top with...

    Just seal the termination plate at the top with hi-temp silicone and shove insulation around the pipe up top. Then layer insulation around the damper and pipes. You should have no cold air...
  4. Replies
    4
    Views
    1,039

    Go with a direct vent fireplace. They are on...

    Go with a direct vent fireplace. They are on average 70% efficient, and completely sealed from your house.

    They also make masonry chimney connectors so that it can draw fresh air from the...
  5. Replies
    3
    Views
    1,130

    Go with a direct vent fireplace. They are on...

    Go with a direct vent fireplace. They are on average 70% efficient, and completely sealed from your house. They are also very forgiving as far as what you can do for venting.

    They also make...
  6. Replies
    6
    Views
    2,781

    With home being built so air tight these days,...

    With home being built so air tight these days, draft problems are more common than you think. I know a lot of people who have to "pre-heat" their liner. If it still smokes into the house after a...
  7. Replies
    10
    Views
    4,245

    The pilot oriface is setup correctly, the house...

    The pilot oriface is setup correctly, the house has NG and it is setup for NG. I guess the flame looked a bit on the large side, but not horribly large. The pilot adj screw did absolutely nothing...
  8. Replies
    3
    Views
    769

    Most fireplace manufacturers have conversion kits...

    Most fireplace manufacturers have conversion kits you can purchase that come with instructions. Constact a dealer/distributor to see if this is the case
  9. Replies
    10
    Views
    4,245

    Thermopile mv reading: Can it be too high?

    Recently I replaced the thermopile on a gas log fireplace(White Rogers Valve). The old TP was reading about 140 with only the pilot running. So, replacement seemed like it would do the trick. I...