  1. Replies
    15
    Views
    1,083

    More freon!

    More freon!
  2. Thread: X13 motors

    by pony
    Replies
    19
    Views
    8,249

    What about lennox CBX27 x13 motor,heard anything...

    What about lennox CBX27 x13 motor,heard anything bad about it?
  3. Old evap coil with r410a pressure,i rather go...

    Old evap coil with r410a pressure,i rather go with lower pressure r22 unit!
  4. Like to try it one day in tight spot!

    Like to try it one day in tight spot!
  5. Replies
    19
    Views
    1,322

    Dont worry!u will get better !

    Dont worry!u will get better !
  6. Replies
    10
    Views
    712

    I usually tell then it take little time to...

    I usually tell then it take little time to circlaire the hot air out before they even open they mouth after i fix it!Lol!i would said about 99% of the customer can feel the cold air cause they have...
  7. Replies
    20
    Views
    675

    if u have proper charge SC should be around...

    if u have proper charge SC should be around 10-12F,do u?
  8. Replies
    20
    Views
    675

    what is SC?

    what is SC?
  9. Thread: what's going on?

    by pony
    Replies
    9
    Views
    527

    sounds like restriction!

    sounds like restriction!
  10. Replies
    107
    Views
    3,927

    Why discontinue dry R22?they are few r22...

    Why discontinue dry R22?they are few r22 replacement refrigerant ozone friendly can put in R22 unit?if goverment concern about seer rating,txv or X13 motor will increase seer rating maybe even 1/2...
  11. Replies
    56
    Views
    1,835

    Mr Udarrell,honor be on the same post with u,read...

    Mr Udarrell,honor be on the same post with u,read a lots of ur online hvac trouble shooting information back when i first start this line of work,thank u!
  12. Replies
    56
    Views
    1,835

    How do u get refrigerant out before u change coil...

    How do u get refrigerant out before u change coil and condenser?if u change wrong indoor coil,u will find out real quick with refrigerant all over ur face when u cut the cooper line indoor coil?so it...
  13. Thread: "A" coil sideways

    by pony
    Replies
    14
    Views
    546

    up and down flow coil ok sideway if u have...

    up and down flow coil ok sideway if u have to,horizontal coil dont think have drain pan on side,so have to install drain pan on the bottom!
  14. Replies
    29
    Views
    954

    bad board will be my first guess!

    bad board will be my first guess!
  15. Thread: Bryant txv

    by pony
    Replies
    164
    Views
    8,754

    Not big fan of txv valve just like ECM motor,to...

    Not big fan of txv valve just like ECM motor,to many fail for different reason,if u install by the book,purge nitro while braze,dons't mean txv not goona mulfuction !cost more money for customer and ...
  16. If i am not mistaken,u r talking about use...

    If i am not mistaken,u r talking about use manifold gauge bring refrigerant from highside to low side cause ur txv was bad clogged?it is good idea ,but first verify the txv is clogged,hook u gauge...
  17. Replies
    17
    Views
    1,017

    put some oil on it,put the wrench on and tap it...

    put some oil on it,put the wrench on and tap it both direction ,
  18. Thread: No Superheat

    by pony
    Replies
    57
    Views
    3,476

    Everytime i runinto low SH and low suction line...

    Everytime i runinto low SH and low suction line temp i will first check either over feeding evap coil or low air flow!
  19. Thread: is everything ok

    by pony
    Replies
    8
    Views
    270

    28F DT kind of high?speed tap on high?condenser...

    28F DT kind of high?speed tap on high?condenser restriction maybe?
  20. I hate to said it,but most regulation and laws...

    I hate to said it,but most regulation and laws have in this country realy just BS to me!just my 2 cent,u will think goverment shouldnt let this kind of refrigerant on the market,but they did!!
  21. Replies
    29
    Views
    1,067

    X2

    X2
  22. Replies
    15
    Views
    690

    I use testo 550 temp clamp porbe today,when i...

    I use testo 550 temp clamp porbe today,when i clamp on 3 or9 oclock temp 8 degree higher then clamp on 6 oclock!i believe copper near ground temp is lower,i maybe wrong!there are different temp on...
  23. Replies
    40
    Views
    1,643

    Frost suction line,low SC and SH=low...

    Frost suction line,low SC and SH=low airflow,frost suction line,high SH with low SC=under charge.it apply most of case,not every case.
  24. Replies
    40
    Views
    1,643

    Esp check will tell u ur airflow correct or...

    Esp check will tell u ur airflow correct or not,most of time i will check the coil condition first and use low restriction air filter if is older system,have few call unit have low SC and SH with low...
  25. Replies
    138
    Views
    5,550

    didnt know those ECM motor save customer money or...

    didnt know those ECM motor save customer money or not?lol!