  1. Replies
    6
    Views
    271

    Those tube things are junk. You need the...

    Those tube things are junk. You need the expanded mesh. Ive had tube units where they could get the panels off and they cut the condenser to get the aluminum out..

    but in all reality you need...
  2. Thread: Bryant txv

    by r-290
    Replies
    164
    Views
    8,754

    Little birdy told me it was cheaper for them to...

    Little birdy told me it was cheaper for them to replace the coil then to pull all the units on the shelf. So yes they are selling know problem units and letting the contractor do the...
  3. Replies
    107
    Views
    3,927

    The building codes here are changing. running...

    The building codes here are changing. running ducts in open attics will be a thing of the past pretty quick on new homes.

    They are making rules so the duct work needs to under the insulation...
  4. Quick note: One should verify the common lead on...

    Quick note: One should verify the common lead on the compressor and where it plugs onto the contactor so you plug the black lead from the 5-2-1 on the correct lug.
  5. Replies
    3
    Views
    305

    you can call the tech rep at your local...

    you can call the tech rep at your local distributor and he can tell you the expected loss. I've done that before when using lines sets not the same size as recommended. Yes you will not get...
  6. Replies
    19
    Views
    832

    Glad you posted that as all the inspector has to...

    Glad you posted that as all the inspector has to say is did you factor in for "not" in free air.

    http://www.barr-thorp.com/wp-content/uploads/2011/04/Digest-176-NEC-Tables.pdf
  7. Replies
    19
    Views
    832

    I don't see where I said that.:putergreet: ...

    I don't see where I said that.:putergreet:

    Maybe I should have told them chase headlights on the freeway?
  8. Replies
    0
    Views
    153

    sound attenuation ideas.

    Ok I just installed a furnace which is in a closet and the return air can is under the unit. Super tight on space.

    They had a 100,000 btu furnace, but load calc came out a lot less as they...
  9. Thread: Old r22 tanks

    by r-290
    Replies
    18
    Views
    873

    Yep, the blacksmith use them to make mini forges....

    Yep, the blacksmith use them to make mini forges.

    EPA says to recover and poke a hole in them.
  10. Replies
    19
    Views
    832

    Ok a couple easy things to remember. If you...

    Ok a couple easy things to remember.

    If you run 100' or more you have to go to the next larger wire.

    14 gauge uses a 15 amp breaker
    12 gauges uses a 20 amp breaker
    10 gauge uses a 30 amp...
  11. Replies
    7
    Views
    206

    I ask the distributor for there match up list. ...

    I ask the distributor for there match up list. just easier on me
  12. The pipe goes in the 90, the same distance as its...

    The pipe goes in the 90, the same distance as its diameter.
  13. Replies
    16
    Views
    744

    FWIW the only part you would see is the...

    FWIW the only part you would see is the bulb.:whistle:

    All the carrier/bryant and trane/AS txv's are factory installed and are inside the cabinet.
    maybe spec some equipment with them...
  14. Replies
    16
    Views
    744

    need Indoor Wet Bulb condenser dry bulb vapor...

    need
    Indoor Wet Bulb
    condenser dry bulb
    vapor pressure
    vapor lime temp.

    if you have a smart ph, down load check and charge
  15. Replies
    68
    Views
    6,032

    in the day and of R22 replacements, having mix...

    in the day and of R22 replacements, having mix refrigerants is a real concern.

    even with the price drop below $250
  16. Replies
    58
    Views
    5,101

    Indirect Waste Connections. Condensate from air...

    Indirect Waste Connections.
    Condensate from air cooling coils and the overflow from evaporative coolers and similar water supplied equipment shall be collected and discharged to an approved plumbing...
  17. Replies
    15
    Views
    983

    Maybe its the combustion air required? Having...

    Maybe its the combustion air required?

    Having a 5" hole in the side of the house might be an issue?

    A bit off topic, but how are you installing them indoors? Say the basement. Are you...
  18. Replies
    15
    Views
    983

    So the regulated heat tape is not burning down...

    So the regulated heat tape is not burning down house then?

    I looked at some stuff at HD, but it said not to use under insulation. Knowing the HO is going to add some insulation at some...
  19. Replies
    17
    Views
    527

    Try this site, its free and recognized by...

    Try this site, its free and recognized by everyone. It will give you the SEER or the AFUE numbers customer need to make decision on.

    http://www.ahridirectory.org/ahridirectory/pages/home.aspx...
  20. Replies
    26
    Views
    1,658

    One thought is to try to use some of the concrete...

    One thought is to try to use some of the concrete block cores to pull air back to the basement.

    You would need to seal those cores or the whole place might smell like the basement :-o
    At least...
  21. Replies
    11
    Views
    696

    x2 Just installed a Bryant heatpump and ...

    x2
    Just installed a Bryant heatpump and
    Sequence of Operation
    HEAT PUMP HEATING MODE
    (1.) Thermostat closes circuits R to G and R to Y. The
    compressor, indoor and outdoor fans are energized

    ...
  22. Thread: keeping dry

    by r-290
    Replies
    22
    Views
    765

    Out west they use a lot of roof top package...

    Out west they use a lot of roof top package units. I have these neo magnets that are super strong, I could tape them to the umbrella handle and stick it to the side of the unit. It's not to keep...
  23. Thread: keeping dry

    by r-290
    Replies
    22
    Views
    765

    What about some type of hands free umbrella?

    What about some type of hands free umbrella?
  24. Thread: keeping dry

    by r-290
    Replies
    22
    Views
    765

    I would get a water resistance tool bag too. I...

    I would get a water resistance tool bag too. I find my tools get wet which never does them any good.
    I have a plastic tool box a friend gave me and it works good. My issue is it normally windy...
  25. Replies
    11
    Views
    622

    Oh, cold day here is like 30's I got a fix...

    Oh, cold day here is like 30's

    I got a fix for ya. Turn the attic into semi conditioned space.

    I guess that works when you can stand up in attic. I just spend like 10-12 hours working in...
Results 1 to 25 of 499