  1. Replies
    34
    Views
    3,704

    Thanks for so much advice. It is certainly...

    Thanks for so much advice. It is certainly helpful. Appears to me in reading all the posts/advice that the current best approach at this point is verify there are no restrictions (which requires...
  2. Replies
    15
    Views
    1,254

    I'm interested in books along a couple fronts but...

    I'm interested in books along a couple fronts but would summarize as some theory (psychrometrics and superheat/subcooling), residential system design including ductwork, and practical field...
  3. Replies
    15
    Views
    1,254

    Anyone have a good HVAC book to recommend? Saw...

    Anyone have a good HVAC book to recommend? Saw this on Amazon

    Troubleshooting and Servicing Modern Air Conditioning and Refrigeration Systems by John Tomczyk

    Appears comprehensive but can...
  4. Replies
    34
    Views
    3,704

    Recovered some R-22 today and now have the...

    Recovered some R-22 today and now have the following readings:

    Liquid Line
    250psig >> ~117.5 deg F
    80 deg F (reading taken near service valve)
    ---------
    37.5 deg F SC (should not exceed 15 deg...
  5. Replies
    34
    Views
    3,704

    Assuming there is a partial restriction and #84...

    Assuming there is a partial restriction and #84 orifice is too small, what would be the best way to determine what the size of the orifice should be? I spoke to RUUD customer support yesterday and...
  6. Replies
    34
    Views
    3,704

    Just updated....did not see that it was germane...

    Just updated....did not see that it was germane to my query for advice but I'm happy to provide that info. ;-)
  7. Replies
    34
    Views
    3,704

    Added R-22 today and took the following readings:...

    Added R-22 today and took the following readings:

    Liquid Line
    275psig >> ~123 deg F
    80 deg F (reading taken near service valve)
    ---------
    43 deg F SC...
  8. Replies
    12
    Views
    1,581

    Last year I worte about this same...

    Last year I worte about this same issue...Copeland Scrollin a RUUD 4-ton. I'd say the sound is like a muffled jack hammer. Was just at in-laws home and they had an 4-ton American Standard condensor...
  9. Replies
    34
    Views
    3,704

    Interesting comments as postings in the For Your...

    Interesting comments as postings in the For Your Interest Fourm that speak to system efficiency discuss SH and SC but do not directly speak to CFM and Static Pressure.

    I could see where that may...
  10. Replies
    34
    Views
    3,704

    No frost evident. Liquid Line just as it enters...

    No frost evident. Liquid Line just as it enters evaporator is cold to the touch but no frost. I would not expect a restriction and suspect undercharge but was hopeful Superheat and Subcooling info...
  11. Replies
    4
    Views
    1,346

    Is there any periodic time that a Filter Dryer...

    Is there any periodic time that a Filter Dryer should be changed (i.e. every five years...)?

    Also if a piston system does not have a sight glass installed should one be installed as an additional...
  12. Replies
    34
    Views
    3,704

    Evaporator has a sticker which reads "Unit...

    Evaporator has a sticker which reads "Unit equipped with piston #84." I'm not clear how to determine undersized piston when this came factory installed.

    Could additional R-22 be added in...
  13. Replies
    19
    Views
    10,958

    Originally posted by NormChris [B] ...

    [QUOTE]Originally posted by NormChris
    [B]

    Can you list the books you'd recommend?
  14. Replies
    34
    Views
    3,704

    Following readings were taken today on a RUUD...

    Following readings were taken today on a RUUD 4-ton R-22 system:

    Liquid Line
    200psig >> ~101 deg F
    80 deg F (reading taken near service valve)
    78 deg F (reading taken about 6" from entry to...
  15. Replies
    21
    Views
    4,362

    TVX Install Cost

    Can any system have a TXV installed?

    [Edited by pehanlon on 06-16-2005 at 08:39 AM]