    try looking at the oil passages on the side of...

    try looking at the oil passages on the side of the compressor on(sv2) they sometimes get blocked and wont allow compressor to load
  3. if that is a Copeland screw ( can't tell by pics...

    if that is a Copeland screw ( can't tell by pics ) it is a bitzer, Copeland just repainted and put there sticker on it
  4. Replies
    26
    Views
    2,153

    as BALloyd said, you dril it you own it. If there...

    as BALloyd said, you dril it you own it. If there was to be a fire or something and they find it started because you drilled the orifices, do you REALLY want that on your conscience?
  5. Replies
    89
    Views
    6,900

    all you can do is be honest with your boss and...

    all you can do is be honest with your boss and explain what happened, don't think he should fire you over it, but next time something like that happens, you might want to talk to the facilities...
  6. Replies
    49
    Views
    6,629

    ac tech makes a simple easy to use drive to use...

    ac tech makes a simple easy to use drive to use and good tech support, but abb does make a very good drive been dealing with them for a few years now and are good drives
  7. crack in the porcelain around the spark rod?

    crack in the porcelain around the spark rod?
  8. Replies
    3
    Views
    413

    all fans should be rotating in the same direction...

    all fans should be rotating in the same direction so the air goes through the unit more evenly and the drive will speed up or slow down to maintain static setpoint, do need to have drive programmed...
  9. Replies
    4
    Views
    383

    cracked plastic mounting block under 7800n...

    cracked plastic mounting block under 7800n control??? found one recently where the plastic on the base of the control was broken and the connection inside the base was not lining up properly and...
  10. Replies
    32
    Views
    3,691

    you should red tag that and call gas inspector...

    you should red tag that and call gas inspector AND the gas company, can't believe ANYBODY would leave that and think " yeah I like that "
  11. Replies
    5
    Views
    529

    what kind of burner is it on? (power flame/...

    what kind of burner is it on? (power flame/ eclipse, etc.) what unit is it in?
  12. Replies
    5
    Views
    529

    the green flashing light is normal and not an...

    the green flashing light is normal and not an indicator of an alarm the red light is for alarms and unfortunately, you can only see what the alarm is if you have the plug in display
  13. Replies
    70
    Views
    13,622

    I would be afraid of someone rear ending me...

    I would be afraid of someone rear ending me especially with the oxy/acetylene rig right there at the back
  14. Replies
    2
    Views
    361

    carrier p/n 33PILOT-01 pg 6 3rd paragraph down on...

    carrier p/n 33PILOT-01 pg 6 3rd paragraph down on right side of page
    "if the system pilot is displaying a controller default screen and the scroll up and scroll down are pressed together for 3...
  15. Replies
    0
    Views
    276

    dunham busch esp3036 hv system

    does anybody know where I can get some information on dunham busch esp 3036 units specifically the dimensions for the drain pan, had two go bad and don't want to walk into customers space again just...
  16. Replies
    7
    Views
    1,310

    Nice job on the install but the duct guy should...

    Nice job on the install but the duct guy should have used a caulking gun to do the sealer or atleast a smaller brush, that's a lot of sealer on them ducts and takes away from your good job
  17. x2

    x2
  18. Replies
    27
    Views
    4,606

    that is not all that counts, The unit is too...

    that is not all that counts, The unit is too close to the wall it will not breathe right and should have replaced the disconnect as well, anyway NEATNESS helps show the customer that you are a...
  19. Replies
    30
    Views
    2,734

    sounds like a good offer and sounds like you...

    sounds like a good offer and sounds like you already made up your mind, need to have a boss you can talk too and get results, probably why I have been with my company for 14 yrs and counting
  20. Replies
    12
    Views
    1,341

    x2

    x2
  21. Replies
    19
    Views
    1,619

    try using a sharpie over the nameplate go over...

    try using a sharpie over the nameplate go over the numbers and rub off with your finger should "raise" the numbers up for you to be able to see
  22. Replies
    24
    Views
    2,803

    nice job but I would have put that concentric out...

    nice job but I would have put that concentric out a little further and why no purple cleaner here in mass required just asking
  23. if the name plate is still on unit sometimes you...

    if the name plate is still on unit sometimes you can run a sharpie over the m/n s/n rub it with your finger to remove excess ink and read numbers through the marker
  24. Replies
    13
    Views
    3,492

    that is fn discusting

    that is fn discusting
  25. Replies
    19
    Views
    4,133

    that is the classic Monday morning after hard...

    that is the classic Monday morning after hard weekend or the rush to get out on Friday unit
  26. Replies
    18
    Views
    3,467

    did the o so smart college kids install that...

    did the o so smart college kids install that themselves?
  27. Replies
    14
    Views
    4,757

    x2 using hot water to melt ice works very...

    x2 using hot water to melt ice works very quickly, imo faster than a heat gun
  28. they should send the bill for the new unit...

    they should send the bill for the new unit install to the other company and tell them since they pulled all the wiring out and bypassed safeties they should pay for the new unit and cancel that...
  29. Replies
    11
    Views
    2,400

    who in Their right mind would do a job like that...

    who in Their right mind would do a job like that and think "wow that looks good "
  30. Replies
    11
    Views
    2,400

    and it won't cost too much to run that in a/c...

    and it won't cost too much to run that in a/c with ducts not being insulated? and is that all 1 ft jts and a couple of elbows or am i missing something?
  31. Replies
    18
    Views
    3,506

    i would have put shut off valves before and after...

    i would have put shut off valves before and after pump for easier future replacement of pump instead of having to drain down whole system, but i understand broke friend and just trying to get it...
  32. Replies
    9
    Views
    810

    the "by pass " is actually a check valve used if...

    the "by pass " is actually a check valve used if the unit was put on a heat pump am stand and trane do that with all there indoor coils ( at least all that I have seen ) so everyone of them can be...
  33. Replies
    41
    Views
    7,264

    i was thinking " Beverly hill billies " myself...

    i was thinking " Beverly hill billies " myself :grin2:
  34. Replies
    14
    Views
    2,630

    you def need to call code enforcement that is...

    you def need to call code enforcement that is just awful looking, that wiring could not have been done by an electrician at least not a good one
  35. you can go with no trap on the ac because it is...

    you can go with no trap on the ac because it is an updraft blower and will always be positive pressure on the drain but no do not go with out a trap on furnace especially if tying in drains together....
  36. Replies
    6
    Views
    543

    if it is a 3 ph comp try to reverse phasing on...

    if it is a 3 ph comp try to reverse phasing on it, had an old timer tell me to do that once and it worked, got better pressures, it did trip oil pressure switch a week later, and found there is apick...
  37. and make sure to use the right oil i found out...

    and make sure to use the right oil i found out the hard way that not all air compressor oils are the same,i had replaced a bad compressor and went back a week later to change oil and compressor was...
  38. Replies
    5
    Views
    647

    maxi-vac makes a good one with a wand that if you...

    maxi-vac makes a good one with a wand that if you pull handle 1 way it is low pressure to apply the cleaner,push it the other way for high pressure rinse works good get it at united refrigeration or...
  39. Thread: on call

    by Mike Doran
    Replies
    134
    Views
    15,337

    when i was first doing on call had one of the...

    when i was first doing on call had one of the senior techs that i got along with tell me to call him if i ever got into a situation i could not handle at any time night or day, that helped ease my...
  40. is the ductwork " bullnosed " under the rtu? i...

    is the ductwork " bullnosed " under the rtu? i have a couple of units that the installing contractor did this to on 2 200 ton units and could not get the static down in the ducts have to run duct...
  41. Replies
    11
    Views
    887

    are you giving it a speed reference? or is the...

    are you giving it a speed reference? or is the drive reading static and controlling itself?
  42. Thread: Visual PM

    by Mike Doran
    Replies
    24
    Views
    5,451

    take them down yourself and take to scrap yard...

    take them down yourself and take to scrap yard you should be able to get some cash for the coils
  43. Thread: Cleaning

    by Mike Doran
    Replies
    24
    Views
    2,405

    i have used used evap foam cleaner in the aerosol...

    i have used used evap foam cleaner in the aerosol can and pump sprayer to flush out after foam breaks, just keep the shop vac running so you don't get water everywhere may need to do it a few times...
  44. Thread: Cleaning

    by Mike Doran
    Replies
    24
    Views
    2,405

    i have used used evap foam cleaner in the aerosol...

    i have used used evap foam cleaner in the aerosol can and pump sprayer to flush out after foam breaks, just keep the shop vac running so you don't get water everywhere
  45. Thread: BAC damper

    by Mike Doran
    Replies
    4
    Views
    600

    wd40 will collect dust and bind up dampers try...

    wd40 will collect dust and bind up dampers try using graphite spray, started using it on outside air dampers and works great drys and does not collect dust
  46. Replies
    81
    Views
    8,954

    been out of high school for about 21 years now...

    been out of high school for about 21 years now but i still hear my electrical teacher every time i go to check for power or after getting bit " never trust a switch ALWAYS check with your meter to...
  47. Replies
    81
    Views
    8,954

    sounds like someone got bit a few times not...

    sounds like someone got bit a few times not turning power off! lol
  48. Replies
    37
    Views
    4,420

    i like to work 50 hrs a week to but just a few...

    i like to work 50 hrs a week to but just a few years ago i would be leaving my house at 7 am and coming home at 8 or 9 at night, even my boss was saying slow down your gonna burn out well i did for...
  49. Replies
    17
    Views
    2,853

    400 cfm of air per ton so yes

    400 cfm of air per ton so yes
  50. Replies
    29
    Views
    4,644

    low voltage wiring is hanging lose instead of...

    low voltage wiring is hanging lose instead of being zip tied to liquid tight