Search:

Type: Posts; User: STEVEusaPA

Page 1 of 10 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    23
    Views
    457

    Of course document everything, before and after. ...

    Of course document everything, before and after. But be very careful with holding/not returning their deposit. Laws are very clear what you have to do, to legally deny them their deposit, and the...
  2. Replies
    6
    Views
    290

    What kind of thermostat. There may be a few...

    What kind of thermostat. There may be a few things happening at almost the same time. For example, with a heat pump, maybe the aux heat changes the fan speed. Maybe you have a thermostat that...
  3. There is no issue to shut off main water supply...

    There is no issue to shut off main water supply for heating itself since it's closed water loop.
    Not entirely true. If your boiler or system leaks, and the boiler has no water in it, you will dry...
  4. Also when it comes on, what does the thermostat...

    Also when it comes on, what does the thermostat read as far as mode.
  5. Replies
    4
    Views
    523

    Rigid and Rothenberger Pipe threaders. The Roth...

    Rigid and Rothenberger Pipe threaders. The Roth and Rigid are an extra 30% off here:
    http://www.zoro.com/g/Pipe%20Threading%20Machines/00063035/
  6. why? make sure the hole were the thermostat wire...

    why? make sure the hole were the thermostat wire penetrates the wall is sealed, the t-stat is not on an outside wall, and set the thermostat for comfort-don't get too hung up on the actually number....
  7. Replies
    4
    Views
    382

    Well if its coming from his garage heater and...

    Well if its coming from his garage heater and into your home, it's carbon monoxide. Why not put a CO detector on your window sill to confirm. It also could be coming from his heater, up into your...
  8. Replies
    4
    Views
    382

    The furnace may not be the main culprit. Is this...

    The furnace may not be the main culprit. Is this a new install or a new problem? Dirty/clogged air filter. Could be mold. Could be the air is too dry (no/broken humidifier). Could be your indoor...
  9. Replies
    6
    Views
    531

    I have 100's of PDF manuals on my iPad and iPhone.

    I have 100's of PDF manuals on my iPad and iPhone.
  10. I love the guy near the end just going...

    I love the guy near the end just going ayyyyyyyyyy into the cell phone.
  11. Replies
    6
    Views
    531

    What will you be using it for?

    What will you be using it for?
  12. Your contractor is mostly right. Deep setbacks...

    Your contractor is mostly right. Deep setbacks are not recommended. The boiler is adjusting (resetting) the boilers target temperature based on the outdoor temperature.
    Depending on the type if...
  13. Replies
    15
    Views
    574

    Like cjp I'm not worried but concerned. Look at...

    Like cjp I'm not worried but concerned. Look at the NYC doctor. He went to a restaurant, bowling and I think 3 subway rides. That easily close contact with 1000s of people...putz
    What happened to...
  14. Meteorologist? They can't tell me what's going...

    Meteorologist? They can't tell me what's going to happen 6 hours from now with sometimes 50% accuracy. Check out tonight's (Sunday) seven day forecast. I'll guarantee they'll be wrong by thursday....
  15. Wait until fracking completely destroys the water...

    Wait until fracking completely destroys the water table in this country, if not most of the planet
  16. Replies
    1
    Views
    277

    Take it to the supply house. They have a full...

    Take it to the supply house. They have a full catalog to cross reference.
  17. Replies
    15
    Views
    646

    To consolidate what some of the previous posters...

    To consolidate what some of the previous posters stated, just turning up a thermostat doesn't fire the boiler. It should open a zone valve. Some of the zone valves can take up to three minutes to...
  18. Replies
    5
    Views
    360

    ....besides call out a pro and have it fixed?...

    ....besides call out a pro and have it fixed? Will take them 2 minutes to initially figure out your problem.
    I think....I THINK....somewhere (actually everywhere) on this site it says no DIY.
  19. Replies
    10
    Views
    486

    You got 2 ears and one mouth....use the ears...

    You got 2 ears and one mouth....use the ears twice as much as your mouth.
    In all seriousness, your enthusiasm, and your desire to learn can take you the farthest.
  20. He's most likely violating your states labor law....

    He's most likely violating your states labor law. I would total up how much he owes you, and contact your attorney
  21. Replies
    11
    Views
    549

    I think it's a bad idea, and a waste of...

    I think it's a bad idea, and a waste of time/money.
    Did the trouble start with the new boiler? It's possible the boiler is the wrong size, a new (wrong) circ was installed, or the near boiler...
  22. This may be the place to find the answer: ...

    This may be the place to find the answer:

    http://www.radiantprofessionalsalliance.org/Pages/AboutUs.aspx
  23. Some answers to your questions 1. Could be a...

    Some answers to your questions
    1. Could be a draft/combustion/chimney problem.
    2. No. You need those gaskets to prevent the products of combustion (containing carbon monoxide) from entering the...
  24. Replies
    16
    Views
    635

    Yikes

    There is no time zone in France that was 'Sunday' at the time of his post....especially the 'countryside'
    http://www.happyzebra.com/timezones-worldclock/USA-and-France.php
  25. Replies
    16
    Views
    635

    1:51pm EST is 7:51pm in France.....oui?

    1:51pm EST is 7:51pm in France.....oui?
  26. Replies
    16
    Views
    635

    Isn't it Saturday at the time of your first post,...

    Isn't it Saturday at the time of your first post, you keep saying its Sunday. Look up the name/model # of your burner and type it into youtube.
    But it really may be more then just bleeding a fuel...
  27. Replies
    17
    Views
    1,263

    I like these...

    I like these
    http://www.myflukestore.com/p18967/fluke-tl223--1-suregrip-electrical-test-lead-set
  28. Replies
    42
    Views
    1,598

    Here's a great place for DIY........

    Here's a great place for DIY.....
    http://t.homedepot.com/?cm_mmc=SEM%7CG%7CBT1&gclid=CMLe78u9j8ECFRJk7AodBBsApA&gclsrc=aw.ds:LOL:
  29. Replies
    12
    Views
    570

    Why don't you ask to see the utility bills?

    Why don't you ask to see the utility bills?
  30. Replies
    7
    Views
    386

    Radiant heat? I think the staple up with aluminum...

    Radiant heat? I think the staple up with aluminum plates are the better way to go if you can't go warmboard, and your not going with embedded. Lower water temps, more even heat distribution.
    What...
  31. Replies
    13
    Views
    727

    There was a thread here, can't find it, a video...

    There was a thread here, can't find it, a video about the proper way to use snips. Reds and greens are used depending on which way you want the waste to peel off-either hand. Yellows are used for...
  32. Replies
    8
    Views
    461

    260k miles? Does he tell people with 20 year old...

    260k miles? Does he tell people with 20 year old equipment, that he'll get a few more years out of it, or replace with new? My van is 5 years old. The one before that had 2 engines, 2...
  33. Replies
    56
    Views
    3,021

    Hang in there, get your education. You don't say...

    Hang in there, get your education. You don't say where you are from, but if you're in the Philadelphia area (or possibly other major cities) within a year they are predicting (with all the work...
  34. Replies
    17
    Views
    1,039

    BTW, be careful with stopping payment on a check....

    BTW, be careful with stopping payment on a check. Some municipalities may charge her with a 3rd degree felony. The rationale being, the customer committed fraud by paying with a check they knew...
  35. Replies
    2
    Views
    312

    Yeah it's wired wrong. You're looking at the...

    Yeah it's wired wrong. You're looking at the wrong diagram. Go to the manufacture's web site and get the right one. Also did you check your LWCO with a meter to make sure it's wired right?
  36. i would use remote sensors and put the tstat in a...

    i would use remote sensors and put the tstat in a closet you can lock...to pay for that, i would take the money from the wife and kids (if you give them an allowance). Or you can let them put the...
  37. Hi from Delaware County...hot one today

    Hi from Delaware County...hot one today
  38. Replies
    12
    Views
    1,106

    That's a new one on me...The building inspector's...

    That's a new one on me...The building inspector's liability is nothing. He will always say something to the effect.."It was fine when I inspected it. I can't tell you what may have happened, or...
  39. If it's a spirovent you're probably fine. If...

    If it's a spirovent you're probably fine. If it's an older type air scoop, still need 18".
  40. IMHO, I would go with heat pump and oil backup. ...

    IMHO, I would go with heat pump and oil backup. You will use the oil backup a little more then you think, and I think the electric back up would be more expensive. Forget propane, especially after...
  41. Your thermostat may have a setting for this. If...

    Your thermostat may have a setting for this. If there is a switch for Fan that has 'On' and 'Auto' switch it to 'On'. If your thermostat doesnt have this ability, have someone install one that can....
  42. Dont get the WM, for one simple reason, its a...

    Dont get the WM, for one simple reason, its a pinner. Practically no one will clean it correctly, and this will shorten its life. I like a triple pass boiler with an indirect.
    More important is a...
  43. Also, don't just trash those radiators, they are...

    Also, don't just trash those radiators, they are worth some big bucks, especially if they are ornate. You could post them for sale on the other-mentioned site.
  44. Replies
    2
    Views
    262

    Always use the EDR method, just make sure you're...

    Always use the EDR method, just make sure you're right. Remember most steam systems were expertly designed by people much smarter then you (and me)--no offense. Also the system was designed to...
  45. Replies
    7
    Views
    700

    FWIW, I think you have to start somewhere. It's...

    FWIW, I think you have to start somewhere. It's definitely a good experience to see how a large company handles their business. Just don't be surprised if a lot of that '8 weeks' is sales/upgrade...
  46. Replies
    10
    Views
    510

    What's a helper?:gah:

    What's a helper?:gah:
  47. this may get you started...

    this may get you started
    http://www.openxtra.co.uk/articles/calculating-heat-load
  48. x100... Hand pump only, or change the line. ...

    x100...
    Hand pump only, or change the line. Also figure out why it is blocked--tank needs to be cleaned/treated, filter not near oil tank or never changed (blocked), line kinked, etc.
  49. Replies
    20
    Views
    748

    ...Radiant under hardwood isn't a really good...

    ...Radiant under hardwood isn't a really good idea. The heat transfer is not good and the hardwood will dry out and shrink.

    Not really true. Depends on how it's designed, water temperatures,...
  50. Thread: Need Advice

    by STEVEusaPA
    Replies
    11
    Views
    451

    Depending on how your house is insulated, new/old...

    Depending on how your house is insulated, new/old windows, for your size house, 930g/year (average) isn't really bad.
    You should also consider insulation & window upgrades (if needed).
Results 1 to 50 of 455