Search:
Type: Posts; User: jksmylieone
Search: Search took 0.06 seconds.
-
06-16-2007, 07:01 AM
- Replies
- 20
- Views
- 2,891
I got my brake from Harbor freight tools. it cast...
I got my brake from Harbor freight tools. it cast around $165 and works preety good up to 24gauge
-
06-09-2007, 04:24 PM
Thread: A/C Security
by jksmylieone- Replies
- 19
- Views
- 4,207
I could have used that security system on a job I...
I could have used that security system on a job I did on monday. Went out for no cooling only to find a disconnect and pad. the lineset was sawwed of at the wall.
-
02-02-2007, 06:14 PM
Thread: Shame on WDIV tv
by jksmylieone- Replies
- 6
- Views
- 461
Shame on WDIV tv
I saw an article about this in the HVAC news dasted jan 29, 2007 this is why our trade has such a bad rep. veiw it for your self at www.shameonwdiv.com
RUTH TO THE RESCUE: Call utility firm... -
01-06-2007, 12:36 PM
Thread: whats the oldest system u ever seen?
by jksmylieone- Replies
- 29
- Views
- 2,287
I think I can top that, I've got a couple old...
I think I can top that, I've got a couple old Niagra coal conversions in north east ohio that go back to 1907, one is so old it has a Beckett Commodore burner on it.
-
12-31-2006, 10:01 AM
Thread: What a Jacka$$
by jksmylieone- Replies
- 19
- Views
- 5,034
Doug you should tell your service manager to...
Doug you should tell your service manager to hire this guy. it looks as if he is more competent than some of your rnc guys
-
12-31-2006, 09:34 AM
Thread: Carrier 58mvb100 error 31
by jksmylieone- Replies
- 19
- Views
- 5,807
Tell your dealer to hook an infinity/evolution...
Tell your dealer to hook an infinity/evolution control to the board as a diagnostic tool. have him look at the inducer rpm and see if it drops below the reguired range to make your pressure switch. I...
-
12-03-2006, 03:41 PM
- Replies
- 15
- Views
- 4,139
Doug I had a similar expirence a few weeks back...
Doug I had a similar expirence a few weeks back while investigation an odor of "deisel fumes" turns out thr Stainless triple wall came apart in thr attic and shifted domw about 8 inches it took 2...
-
09-10-2006, 05:47 PM
Thread: Trane Voyage
by jksmylieone- Replies
- 23
- Views
- 3,694
Nice job guys, we are doing a similar job with 2...
Nice job guys, we are doing a similar job with 2 80ton condensors and airhandlers on thanksging day
-
09-02-2006, 05:56 PM
Thread: Inserts ??????
by jksmylieone- Replies
- 9
- Views
- 1,058
I use a hearthstone insert in my fireplace. The...
I use a hearthstone insert in my fireplace. The insert and the fan on switch at my stat is all i use to heat 2200 sq ft up to about 72 degress, all on about 6 logs every day. this works until the...
-
09-02-2006, 02:48 PM
Thread: Good Thing It's Hard To Stop A Trane
by jksmylieone- Replies
- 14
- Views
- 4,527
Doug thats almost as bad as three village!!!
Doug thats almost as bad as three village!!!
-
09-02-2006, 02:45 PM
- Replies
- 54
- Views
- 9,242
I agree 100% with Doug. Infact I worked for the...
I agree 100% with Doug. Infact I worked for the same scumbag, and the same large company. Infact doug and I have done some jobs together. I always file a form 1099 with the govt for my work and i...
-
09-02-2006, 02:24 PM
Thread: Need New Furnace
by jksmylieone- Replies
- 6
- Views
- 619
the carrier and bryant are identical products....
the carrier and bryant are identical products. some trane and am std are identical. from a service point of veiw go with the carrier or bryant 90+, which ever brand was quote as cheaper. other than...
-
09-02-2006, 08:41 AM
Thread: American Standard vs Carrier
by jksmylieone- Replies
- 24
- Views
- 2,487
I would go with the carrier system BUT not thier...
I would go with the carrier system BUT not thier stat. Tell the company you want a White Rodgers 1F90 series programable stat or the new White Rodgers touch screen stat
-
09-02-2006, 08:38 AM
Thread: Rules on recharging with Freon
by jksmylieone- Replies
- 31
- Views
- 2,158
Many of the larger more reputable companies...
Many of the larger more reputable companies require techs to reccomend a leak search if more than 2 pounds are added to the system. As long as the customer declines the search it stops there. I can...
-
09-02-2006, 08:33 AM
Thread: ultimate thermostat for 10M home
by jksmylieone- Replies
- 46
- Views
- 2,942
If you would have sold him on Bryant/ Carrier you...
If you would have sold him on Bryant/ Carrier you could have used an evolution/ infinity contrl. this stat will do everything but your dishes
-
07-23-2006, 06:12 PM
Thread: Carrier 48tfe
by jksmylieone- Replies
- 4
- Views
- 1,311
In the last 2 days i have found 2 differnent...
In the last 2 days i have found 2 differnent carrier 48 tfe's leaking from the tube sheets on the condensor coil. my boss insist that i cut out the tube sheets and repair the leaks at all cost. even...
-
06-10-2006, 07:31 AM
Thread: Why won't our A/C work?
by jksmylieone- Replies
- 5
- Views
- 3,178
that sure beats the chewing gum wrapper i removed...
that sure beats the chewing gum wrapper i removed from a carrier circuit board 2 weeks ago. never knew that big red was rated a 3 amps
-
05-07-2006, 09:20 AM
- Replies
- 3
- Views
- 792
Go for the wood burning inserts. they dont have...
Go for the wood burning inserts. they dont have to be that expensive. just shell out the extra few bucks and have a stainless liner installed in your chimney. I heat my entire house (2500 sq ft) with...
-
05-07-2006, 09:14 AM
Thread: wood burning insert
by jksmylieone- Replies
- 2
- Views
- 1,196
I heat my house, (approx 2500 sq ft) with a wood...
I heat my house, (approx 2500 sq ft) with a wood burning insert. i am able to keep the house between 69- 74 degrees depending on the out side temp. if you are considering an insert find the dealer...
-
03-27-2006, 07:17 PM
Thread: Another Reason
by jksmylieone- Replies
- 6
- Views
- 1,839
Doug nice pic of the HWT, did D.W. do the piping...
Doug
nice pic of the HWT, did D.W. do the piping over there
jim -
03-27-2006, 07:09 PM
Thread: carrier vvt
by jksmylieone- Replies
- 5
- Views
- 530
I have a slave stat that is locked up in the set...
I have a slave stat that is locked up in the set back mode, showing HF 12. I removed the ribbon connector and swapped stats with another suite. the original stat works in its new location, but the...
-
02-25-2006, 05:38 PM
Thread: You Have To Change The Filter??
by jksmylieone- Replies
- 23
- Views
- 3,777
Doud I forgot My camera that day, but last week i...
Doud I forgot My camera that day, but last week i was on a call that you did about this time last year, for hang on now ............... a dirty filter. guess what I was there for hang on................
-
02-25-2006, 05:24 PM
Thread: No more high gas bills.
by jksmylieone- Replies
- 20
- Views
- 1,676
Being lead tech for a bryant master dealer, I...
Being lead tech for a bryant master dealer, I regretfully have to say that although I have a bryant 90+ variable speed furnace I refuse to pay the gas company outragous amounts of money. Two weeks...
-
01-28-2006, 08:01 AM
- Replies
- 3
- Views
- 520
I am not one to dog a manufacture, or thier...
I am not one to dog a manufacture, or thier quality but last week I received a heat exchanger for a Heil oil furnace. It was shipped from the factory with the legs missing (supposed to be welded on)....
Results 1 to 24 of 31